This Limited Lifetime Warranty applies only while the unit remains at the site of the original installation 
and  only  if  the  unit is  installed  inside  the  continental  United  States,  Alaska,  Hawaii,  and  Canada.  The 
warranty applies only if the unit is installed and operated in accordance with the printed instructions and 
in compliance with applicable installation and building codes and good trade practices. 

BASIC ONE YEAR WARRANTY 

During  the  first  year  after  installation,  we  will  provide  a  replacement  for  any  component  part  of  your  unit  found  to  be  defective  in 
materials  or  workmanship,  including  labour  costs.  Repair  work  requires  prior  approval  by  Kingsman,  labour  costs  are  based  on  a 
predetermined rate schedule and any repair work must be done through an authorized Kingsman dealer. 
(Excluded Components: Accent Light Bulbs, Gasketing and Paint) 

LIMITED LIFETIME WARRANTY 

The heat exchanger, combustion chamber and burner of every Kingsman product excluding the Outdoor Firepit are warranted again st 
materials or workmanship during the period the product is owned by the original owner. The part to be replaced must be returned to our 
distributor  in  exchange  for  the  replacement  part.  Any  labor,  material,  freight  and/or  handling  charges  associated  with  any  repair  or 
replacement pursuant to this Limited Lifetime Warranty will not be covered by this warranty.  

GENERAL TERMS 

In lieu of providing a replacement part, we may, at our option, provide the distributor's component purchase price from us or a credit 
equal to the 

distributor’s component purchase price from us toward the purchase of any new unit which we distribute. If a credit is given 

in lieu of a replacement part, the rating plate from the unit being replaced must be submitted on a warranty claim, and the unit being 
replaced must be made available to our distributor for disposition.  

In establishing the date of installation for any purpose, including determination of the starting date for the term of this Limited Lifetime 
Warranty, reasonable proof of the original installation date must be presented*, otherwise the effective date will be based upon the date 
of manufacture plus thirty (30) days.  

We  will not be  responsible for  and  you,  the  user,  will pay  for:  (a)  damages caused by  accident,  abuse,  negligence, misuse,  ri ot,  fire, 
flood, or Acts of God (b) damages caused by operating the unit where there is a corrosive atmosphere containing chlorine, fluorine, or 
any other damaging chemicals (other than in a normal residential environment) (c) damages caused by any unauthorized alteration or 
repair of the unit affecting its stability or performance (d) damages caused by improper matching or application of the unit or the unit's 
components  (e)  damages  caused  by  failing  to  provide  proper  maintenance  and  service  to  the  unit  (f)  any  expenses  incurred  for 
erecting, disconnecting or dismantling the unit (g) parts or supplies used in connection with service or maintenance (h) damage repairs, 
inoperation or inefficiency resulting from faulty installation or application (i) electricity or fuel costs or any increase in electricity or fuel 
cost whatsoever including additional or unusual use of supplemental electric heat.  

We shall not be liable for any incidental, consequential, or special damages or expenses in connection with any use or failure of this 
unit.  We  have  not  made  and  do  not  make  any  representation  or  warranty  of  fitness  for  a  particular  use  or  purpose,  and  there  is  no 
implied condition  of  fitness  for  a  particular  use  or  purpose. We make  no  express  warranties  except  as  stated  in  this  Limited  Lifetime 
Warranty.  No  one  is  authorized  to  change  this  Limited  Lifetime  Warranty  or  to  create  for  us  any  other  obligation  or  liability  in 
connections with this unit. Any implied warranties shall last for one year after the original installation. Some states and provinces do not 
allow the exclusion or limitation of incidental or consequential damages or do not allow limitations on how long an implied warranty or 
condition lasts, so the above limitations or exclusions may not apply to you. The provisions of this limited warranty are in  additions to 
and not a modification of or subtraction from any statutory warranties and other rights and remedies provided by law.  

Save  this  certificate.  It  gives  you  specific  legal  rights,  and  you  may  also  have  other  rights  which  may  vary  from  state  to  state  and 
province to province.  

In the event your unit needs servicing, contact your dealer or contractor who installed or serviced your unit. When requesting service, 
please have the model and serial number from each unit readily available. If your dealer needs assistance, the distributor is available 
for support and we, in turn support the distributor's efforts.  

Fill in the installation date and model and serial numbers of the unit in the space provided below and retain this limited warranty for your 
files.  

 

Model No. 

 

Serial No. 

 

Date installed 

 

 

Dealer or Contractor Name:  

 

*To receive advantage of your warranty, you must retain the original records that can establish the installation date of your unit. 

 

The Ultimate in Design, Engineering & Quality 

 

76

Содержание Marquis BZDV4736NE

Страница 1: ...NTED GAS FIREPLACE A Division of R Co Inc 2340 Logan Avenue Winnipeg Manitoba Canada R2R 2V3 Ph 204 632 1962 Printed in Canada September 4 2018 Part 36MQ MAN14 INSTALLER Leave this manual with the app...

Страница 2: ...g Requirements 24 Installing Clean View Kit CVCK 25 Clearance to Combustibles 25 Parts List 26 27 Kingsman Fireplace Venting Parts 27 COMMON SECTION Clearance Mantels Surrounds 28 29 Dimensions Instal...

Страница 3: ...Climates CPI Setting 64 Flame Control Room Thermostat 65 Smart Thermostat Fan Speed Control Light Control 66 Label Schematic 67 VENTING SECTION Vent Termination 68 General Vent Installation Informatio...

Страница 4: ...e with the fan off if a fan is present after the curing of the paint has been completed These odours can last upward to 40 hours of burn time keep burning at a minimum of four hours per use until odou...

Страница 5: ...until unit is COMPLETELY cool before touching glass or attempting to install or remove Child Safety Screens To install screens hook bottom clip onto glass door frame then press down and push upper cli...

Страница 6: ...LLED IN MANUFACTURED MOBILE HOMES IN CANADA Please follow the current ANSI NFPA 70 National Electrical Code in the USA and CAN CSA C22 1 Canadian National Electrical Code in Canada An appliance must b...

Страница 7: ...ce 15 Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequent cleaning ma...

Страница 8: ...in the living area outside the bedroom s The carbon monoxide detector shall comply with NFPA 720 B A carbon monoxide detector shall be located in the room that houses the appliance or equipment and sh...

Страница 9: ...ceiling Therefore 42 of sheltering cover is required above fireplace All wiring connections to line power shall be in accordance with outdoor requirements of NECA NFPA 70 in the USA Canadian Electrica...

Страница 10: ...on Wall Corner F Exterior Wall See Mantel Leg Clearances Instruction for the proper placement of fireplace Island installation with a top vent is possible as long as the horizontal portion of the vent...

Страница 11: ...e the elbow on any horizontal runs of one foot or greater This allows for cleaner combustion and greatly reduces carboning and cleaning of glass MQHBZDV3636 Framing for your Gas Fireplace MQHBZDV36 Lo...

Страница 12: ...CIRCULATING KIT HB36CVCK WITH MQHB36SW SURROUND HBZDV36 Framing and Facing Requirements Non Combustible Header Attached AA Non Combustible Header Attached AA AA AA Non Combustible Header Attached AA...

Страница 13: ...rance to Combustibles Back from Standoffs 0 inches 0 mm Side from standoffs 0 inches 0 mm Floor 0 inches 0 mm Ceiling from bottom of fireplace 60 inches 150 cm Top from standoffs 0 inches 0 mm Top of...

Страница 14: ...Millivolt Z1MT Thermostat Millivolt Wall Mount Z80PT Thermostat Programmable Digital Millivolt Wall Mount 1F80 40 GTRC Remote Control Millivolt Thermostat GTMRCP Remote Control Millivolt Thermostat M...

Страница 15: ...36 42 47 ZDV6000 MDV31 HB models ZDVHSKSQ Horizontal Square Termination Vent Starter Kit 3 FT Length Horizontal Vent Termination Wall Thimble Wall Thimble 36 Flex Pipe Mill Pac ZDVHSKSQ5 Horizontal S...

Страница 16: ...on Wall Corner F Exterior Wall See Mantel Leg Clearances Instruction for the proper placement of fireplace Island installation with a top vent is possible as long as the horizontal portion of the vent...

Страница 17: ...of two and a half 2 5 inches above the bend in enclosures 5 For a fireplace with louvers combustible floor can raise 1 above the bottom of the fireplace For a fireplace with HB42CVCK Clean view Circu...

Страница 18: ...AN VIEW CIRCULATING KIT HB42CVCK WITH MQHB42SW SURROUND Note A HBCVCK must be used when installing a MQHBSW Wall Surround HB42 Framing and Facing Requirements Non Combustible Header Attached Non Combu...

Страница 19: ...ombustibles Back from Standoffs 0 inches 0 mm Side from standoffs 0 inches 0 mm Floor 0 inches 0 mm Ceiling from bottom of fireplace 60 inches 150 cm Top from standoffs 0 inches 0 mm Top of 90 degree...

Страница 20: ...ge 37 3 8 H x 43 3 8 W HB42SLBL Surround Slim Line Gun Metal Black Coverage 37 3 8 H x 43 3 8 W Designer Doors for 42 Fireplaces Operative HB42DDA1BL Designer Door Arch Series 1 Black HB42DDTA1A Trim...

Страница 21: ...ne GE Red IS806 736 1000 150MP Hi Temp Mill Pac Sealant 840099 1000 214 Piezo Igniter 1244 17 MARK 21 1000 215 Pal Nut 18MMXI 5MM BLK 1364 03 1000 218 Switch Ivory 1451 001 1000 227 Cover Ivory 86001...

Страница 22: ...on Wall Corner F Exterior Wall See Mantel Leg Clearances Instruction for the proper placement of fireplace Island installation with a top vent is possible as long as the horizontal portion of the vent...

Страница 23: ...nsulation sleeve is not required 5 For a fireplace with louvers combustible floor can raise 1 above the bottom of the fireplace For a fireplace with HB47CVCK Clean view Circulating Kit floor or hearth...

Страница 24: ...Non Combustible Header Attached Non Combustible Header Attached Non Combustible Header Attached Non Combustible Header Attached 24...

Страница 25: ...fs 0 inches 0 mm Floor 0 inches 0 mm Ceiling from bottom of fireplace 60 inches 150 cm Top from standoffs 0 inches 0 mm Top of 90 degree bend in Minimum with insulation sleeve Enclosure of 50 1 2 to 5...

Страница 26: ...the U S A Thermostats are not permitted for Vented Gas Fireplaces ANSI Z21 50b Z2MT Thermostat Digital Vertical Wall Mount MV PF1 Z80PT Thermostat Programmable Digital Wall Mount MV PF1 GFRC Remote C...

Страница 27: ...al Vent Termination FDVHT Horizontal Vent Termination FDVHSQ Horizontal Square Termination Z47ST24 Horizontal Snorkel Termination 24 Tall 14 1 2 Center to Center Z47ST36 Horizontal Snorkel Termination...

Страница 28: ...the minimum height and width requirements for a combustible mantel Note For the installation of the MQHBSW Maintain Minimum 1 Clearance to Top Sides of the surround Combustible or non combustible mate...

Страница 29: ...r over the front face of the fireplace NO PORTION OF GRILL AREA OR DOOR AREAS CAN BE COVERED except where designer clean view kit is used Combustible material can extend flush to unit up to the top bo...

Страница 30: ...mounting holes on the Lower Tab with the holes on the CVCK Side Frame Using the previously removed screws in Step 1 secure the Lower Tab to the CVCK side frame Replace the old CAP with the new CAP th...

Страница 31: ...set screw on the side of vari able speed controller to increase or decrease the minimum fan speed lowering minimum fan speed will decrease sound level created by fan Reinstall switch into wall mount a...

Страница 32: ...pronged grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Label all wires prior to disconnection when servicing con...

Страница 33: ...Remove 2 DT Screws from Firebox sides Do not discard these screws Place Side Panels into Firebox as shown in Ref 3 below tilt and slide into place Replace and tighten DT Screw through hole in top of S...

Страница 34: ...ce optional front bridge ledge 3 in the area front of false bottom 5 Place rear Brick Panel 4 up against the rear of Firebox by tilting top of panel towards you and sliding bot tom of Panel over the b...

Страница 35: ...k Clip out of the way and slide Side Panel up against Back Panel Side Panel tabs should engage top and bottom of Back Panel See Ref 3 Rotate Brick Clip down over Side Panel and tighten screw 5 Re inst...

Страница 36: ...essures in excess of 1 2 PSIG 3 5 KPa 9 The appliance must be isolated from the gas supply piping system by closing its individual shutoff valve during any pressure testing of the gas supply piping sy...

Страница 37: ...ay and hold it With the other hand push in the red ignitor button until you hear a click Now observe closely the pilot burner located on the rear center left hand side of the main burner If a flame ha...

Страница 38: ...itch If okay jumper wires across wall switch wires at valve If burner comes on wires are faulty or connections are bad Generator may not be Check generator with millivolt meter Take reading at gen gen...

Страница 39: ...ing Burner System 1 Disconnect gas line connection at burner system through access cover opening CAUTION ALL WORK SHOULD BE PERFORMED BY A QUALI FIED AND CERTIFIED TECHNICIAN 2 Remove extension knobs...

Страница 40: ...intermittent or standing pilot system even if the main burner was never on Exercise caution when working within the area ALL WORK SHOULD BE PERFORMED BY A QUALIFIED AND CERTIFIED TECHNICIAN Monthly F...

Страница 41: ...KLP For MQRB4236LPT LP Conversion Millivolt 1001 P167SI 30 977 167 53 1000 P201VE Hex 1 4 1001 P201SI 0 907 201 4236RBT CKLPI For MQRB4236LPTE LP Conversion IPI 1001 P168SI 35 977 168 53 1000 P201VE H...

Страница 42: ...regulator by following instructions supplied with conversion kit also See Parts B C 5 Adjust the primary air setting to the correct setting as specified in the manual or label plate To adjust air sett...

Страница 43: ...e new injector is proper for the application The injector size is stamped on the side of the injector near the top LPG injectors have a groove machined around their circumference near the top while NG...

Страница 44: ...Gas Conversion for Modulator PART C WARNING WARNING 44...

Страница 45: ...heat silicone tempera ture resistant to 500 F 260 C apply a con tinuous bead of approximately 1 32 to all four sides of frame and insert glass with new gas ket Frame should be on flat surface with a...

Страница 46: ...log 6 Place onto the mounting tab on log 2 Locate the 2 holes on the bottom of log 7 Place onto mounting tabs on log 5 STEP 5 Place glowing embers on the front of the burner tube and ember plates Pla...

Страница 47: ...Pilot Shield RSP1 RSP2 Qty 1 Shield Per Kit Back View 1 2 3 4 5 6 SLOTS SLOTS SLOTS SLOTS 47...

Страница 48: ...P 3 Using the platform mount access holes attach the rock platform as shown STEP 4 Fill around the rock platform with lava rock Do not place any lava rock on the burner Sprinkle vermiculite over top o...

Страница 49: ...s 3 onto the burner as shown STEP 7 Place rocks 4 onto the burner as shown STEP 8 Place rocks 6 onto the burner as shown STEP 9 Place remaining rocks 4 and 6 into position as shown Finished Rock F2 Se...

Страница 50: ...nt access holes attach the rock platform as shown STEP 3 Fill around the rock platform with lava rock Sprinkle vermiculite over top of the lava rock Do not place lava rock or vermiculite on top of the...

Страница 51: ...own Do not place rocks directly onto the burner tubes STEP 6 Place rocks 4 into position as shown STEP 7 Place rocks 6 into position as shown STEP 8 Place remaining rocks 4 and 6 into position as show...

Страница 52: ...nition can occur The following types of glass are approved Ember Glass Material from American Fireglass Maximum amount Natural Gas is 5 lbs Propane units 5 lbs Liquid Glass from Firegear Maximum amoun...

Страница 53: ...KIT Optional Accent Lighting Kit See separate installation page NOTE Glass Media must be evenly spread over the Burner and False Bottom as described on last page before Rock Stones and Log Accessorie...

Страница 54: ...t lamp wires through access hole in firebox as above Apply new sealant Mill Pac Secure Lamp Plate with screws Please follow the current ANSI NFPA 70 National Electrical Code in the USA and CAN CSA C22...

Страница 55: ...facing upward or sideways Replace burner tube and false bottom along with pilot shield STEP 4 Connect switch wires between lamp wire and transformer see schematic Connect remaining lamp wire to trans...

Страница 56: ...the remote Contrary to this feature is a Manual HI LO Control Knob The Modulating Servo Motor requires the Remote system to be present Backup Battery Pack This component permits the IPI system to oper...

Страница 57: ...ol wiring harness instead of the main IPI harness From the Remote wiring harness use its male plug in connector and connect it to the female plug in in the main IPI harness Now the circuit is complete...

Страница 58: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 58...

Страница 59: ...anual HI LO capabilities OPTIONAL For units with remote HI LO capabilities a modulating servo is required to be installed on the valve The connectors to this servo must be connected to the Remote Harn...

Страница 60: ...Configuration 3 Remote ON OFF variable HI LO and fan capabilities Refer to the fan installation removal section for fan installation 60...

Страница 61: ...ent LIGHTING INSTRUCTIONS 1 STOP Read the above safety information on this label 2 Remove batteries from Receiver and or Battery Backup Pack 3 Turn off all electric power to the fireplace 4 This firep...

Страница 62: ...920 5 584 PWR C Wire Harness PF2 Main Power Cord 6 1002 P12BH Battery Housing 7 1006 P921si Wire harness for Split flow 0 584 921 Not available 8 1005 P2SCH Label PF2 Schematic Decal 9 584 X12 Power V...

Страница 63: ...must be followed to reset the PF2 Module Press the Red SW1 button until you hear three beeps Within 10 seconds press the SW1 button again until you hear it beep The PF2 Module may now be turned on off...

Страница 64: ...Press UP on the UP DOWN Arrow Key Display will show CPI The module in the fireplace will beep once to confirm command TO RETURN TO IPI INTERMITTENT PILOT MODE Repeat steps one and two and then press...

Страница 65: ...Proflame 2 Remote Control 65...

Страница 66: ...Note When Smart Thermostat is activated manual flame height adjustment is disabled Note This function is only available in Room Thermostat or Smart Thermostat Control Mode 66...

Страница 67: ...67...

Страница 68: ...s both dwellings THIS DOES NOT APPLY to direct vent non condensing appliances in the Province of Ontario M Clearance above highest point of exit on roof 18 inches 45cm N Clearance to perpendicular wal...

Страница 69: ...2 couplers to extend short pipes Single sections are preferred in an installation attaching at the fireplace and ter mination Place the spring spaces provided approximately every two feet to stabiliz...

Страница 70: ...and the number of bends required 2 Having determined the vertical distance determine the maxi mum horizontal section allowed 3 Vent table has been established for 90 horizontal vertical runs With use...

Страница 71: ...the 4 flex pipe as required Then attach the seven inch 7 pipe by the same method 8 Support horizontal pipes every two 2 feet 61 cm with metal strap bands Re check fireplace to make sure it is levelle...

Страница 72: ...two rulers or by using a roof pitch card See figure below Slide a Roof Flashing suitable to your roof slope over the vent Place the edge of the flashing plate that will be on the higher part of the r...

Страница 73: ...eep toddlers young children and other at risk individuals out of the room and away from hot surfaces Do not leave the fireplace remote control where it is accessible to children Termination Cap Safety...

Страница 74: ...s are permitted however Cold Climate Switch Standing Pilot Mode must NOT be used Seven 90 elbows are possible if the total horizontal is not more than 25ft and the vertical does not exceed 15ft Refer...

Страница 75: ...4 6 5 8 venting to 5 8 For Power Vent installations where flex pipe will be used up to the Power Vent unit Z47PVA Pipe Reducer 8 Sm 7 Sm Pipe Reducer 5 Sm 4 Sm Adapts PVH58 to accept 4 7 Flex Pipe On...

Страница 76: ...other than in a normal residential environment c damages caused by any unauthorized alteration or repair of the unit affecting its stability or performance d damages caused by improper matching or app...

Отзывы: