Conversion Kit Instructions – PART A
Kit Number
Description
Pilot Orifice
Burner Orifice
Brass (1000-255)
Brass Nipple
Air Shutter
Hi/Lo Regulator
3632HB -CKLP
For
MQHBZDV3636LP
LP
Conversion
-Millivolt-
1001-P167SI
#30 (977.167)
#51
1000-253closed
5/16”
1001-P202SI
(0.907.202)
3632HB –CKLPI
For
MQHBZDV3636LPE
LP
Conversion
-IPI -
1001-P168SI
#35 (977.168)
#51
1000-253closed
5/16”
1002-P014SI
(0.907.014)
3632HB -CKNG
For
MQHBZDV3636N
NG
Conversion
-Millivolt-
1001-P165SI
#51 (977.165)
#36
1000-253closed
3/16”
1001-P201SI
(0.907.201)
3632HB –CKNGI
For
MQHBZDV3636NE
NG
Conversion
- IPI -
1001-P166SI
#62 (977.166)
#36
1000-253closed
3/16”
1002-P016SI
(0.907.016)
4232HB-CKLP
For
MQHBZDV4236LP
LP
Conversion
-Millivolt-
1001-P167SI
#30 (977.167)
#51
1000-253closed
5/16”
1001-P202SI
(0.907.202)
4232HB –CKLPI
For
MQHBZDV4236LPE
LP
Conversion
-IPI -
1001-P168SI
#35 (977.168)
#51
1000-253closed
5/16”
1002-P014SI
(0.907.014)
4232HB -CKNG
For
MQHBZDV4236N
NG
Conversion
-Millivolt-
1001-P165SI
#51 (977.165)
#36
1000-253closed
3/16”
1001-P201SI
(0.907.201)
4232HB –CKNGI
For
MQHBZDV4236NE
NG
Conversion
- IPI -
1001-P166SI
#62 (977.166)
#36
1000-253closed
3/16”
1002-P016SI
(0.907.016)
4236RB-CKNG
For
MQRB4236N
NG
Conversion
-Millivolt-
1001-P165SI
#51 (977.165)
#36
1000-P201VE
Hex
3/16”
1001-P201SI
(0.907.201)
4236RB-CKNGI
For
MQRB4236NE
NG
Conversion
- IPI -
1001-P166SI
#62 (977.166)
#36
1000-P201VE
Hex
3/16”
1002-P016SI
(0.907.016)
4236RBT-CKLP*
For
MQRB4236LPT
LP
Conversion
-Millivolt-
1001-P167SI
#30 (977.167)
#53
1000-P201VE
Hex
1/4”
1001-P201SI
(0.907.201)
4236RBT –CKLPI*
For
MQRB4236LPTE
LP
Conversion
-IPI -
1001-P168SI
#35 (977.168)
#53
1000-P201VE
Hex
1/4”
1002-P016SI
(0.907.016)
*NOTE:
The
MQRB4236N
CANNOT BE CONVERTED TO LP.
If the MQRB4236NT you wish to convert to LP has a serial number less than #4708
You MUST order the 4236RB-SRKP upgrade kit. (See Gas Conversion –Part A drawings which follow)
4236RBT-CKNG
For
MQRB4236NT
NG
Conversion
-Millivolt-
1001-P165SI
#51 (977.165)
#42
1000-P201VE
Hex
1/32”
1001-P201SI
(0.907.201)
4236RBT-CKNGI
For
MQRB4236NTE
NG
Conversion
- IPI -
1001-P166SI
#62 (977.166)
#42
1000-P201VE
Hex
1/32”
1002-P016SI
(0.907.016)
4740HB-CKLP
For
HBZDV4736LP
LP
Conversion
-Millivolt-
1001-P167SI
#30 (977.167)
#49
1000-253closed
Fully Open
1001-P201SI
(0.907.201)
4740HB-CKLPI
For
HBZDV4736LPE
LP
Conversion
-IPI -
1001-P168SI
#35 (977.168)
#49
1000-253closed
Fully Open
1002-P016SI
(0.907.016)
4740HB-CKNG
For
HBZDV4736N
NG
Conversion
-Millivolt-
1001-P165SI
#51 (977.165)
#31
1000-253closed
5/16”
1001-P201SI
(0.907.201)
4740HB-CKNGI
For
HBZDV4736NE
NG
Conversion
- IPI -
1001-P166SI
#62 (977.166)
#31
1000-253closed
5/16”
1002-P016SI
(0.907.016)
Refer to “Gas Specifications Chart” for inlet pressures and input ratings. Clock meter to verify input rate. Place conversion label as close to
converted gas control as possible. Refer to lighting instructions to verify the normal operating sequence of the ignition system. IMPORTANT:
Always check for gas leaks with a soap and water solution.
DO NOT USE OPEN FLAME FOR LEAK TESTING.
41
Содержание Marquis BZDV4736NE
Страница 44: ...Gas Conversion for Modulator PART C WARNING WARNING 44...
Страница 47: ...Pilot Shield RSP1 RSP2 Qty 1 Shield Per Kit Back View 1 2 3 4 5 6 SLOTS SLOTS SLOTS SLOTS 47...
Страница 58: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 58...
Страница 65: ...Proflame 2 Remote Control 65...
Страница 67: ...67...