background image

 

23

 

Fan Installation/Removal 

 

Fan System 

 

WARNING 

Electrical Grounding Instructions 

This appliance is equipped with a three prong 
(grounding) plug for your protection against 
shock hazard and should be plugged directly into 
a properly grounded three-prong receptacle. Do 
not cut or remove the grounding prong from this. 
 

Before Servicing 

1.  Ensure all power supply is shut off. 
2.  Label all wires prior to disconnecting when 

servicing control. Wiring errors can cause 
improper and dangerous operation. 

3.  For fan servicing: Vacuum and clean lint/dirt 

build-up on the fan blades and motor. 

4.  When resealing the Fan Access Panel, use 

High Temp. Silicone or Millpac. 

 

1.  Remove glass door assembly and log set if 

installed. Be sure to handle logs carefully as 
they become fragile after heated. 

2.  Remove back air shield by unscrewing (4 screws). 

3.  Remove fan access panel (15 screws). It is located on the back and bottom right hand corner. 

4.  Remove the fan from the outer shell (2 screws). The fan needs to be twisted and rotated slightly. The fan's motor end 

will be lifted out first. 

5.  Reinstall fan, bracket and all necessary components, as shown below, once completed. 

6.  Verify proper operation after servicing. 

Caution: 

Label all wires prior to disconnection 

when servicing controls. Wiring errors can 
cause improper and dangerous operation. 
Verify proper operation after servicing. 

Содержание IDV33

Страница 1: ...installation in a zero clearance type listed solid fuel burning factory built fireplace It may be necessary to remove the damper plate refractory liners log grates glass door and screen rails mesh Rem...

Страница 2: ...ell as the finishing materials used with the installations e g marble tile and the adhesives used to adhere this product to the walls can react with heat and cause odours It is recommended that you bu...

Страница 3: ...nd Installation for IDV33 IDV36 Fronts 13 Clearance to Combustible Mantels 14 Venting 15 Installation of Vent Pipe 16 IDV33 IDV36 Riser Kit and Leveling Instructions 17 Glass Door Information 18 Brick...

Страница 4: ...AFTER FIRST SALE Please follow the current ANSI NFPA 70 National Electrical Code in the USA and CAN CSA C22 1 Canadian National Electrical Code in Canada An appliance must be grounded to the steel ch...

Страница 5: ...e 14 Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequent cleaning may...

Страница 6: ...grade the following requirements must be satisfied A If there is not one already present on each floor level where there are bedroom s a carbon monoxide detector and alarm shall be placed in the livin...

Страница 7: ...Dimensions and Sizing I33CV Clean View and Surround Sizes Min Coverage with Optional I33LK or I33CV Base Unit I33LK I33CV Front Width 26 1 4 34 1 2 32 3 4 Rear Width 21 1 4 Height 21 3 8 24 3 8 22 3...

Страница 8: ...rrounds shown here are universal and can be used with the I33CV model Furthermore the I33S4535B and I36S4736B 1 piece Surround was designed to be used as a custom cutout surround Simply trace template...

Страница 9: ...sert Dimensions and Sizing I36CV Clean View and Surround Sizes Min Coverage with Optional I36LK or I36CV Base Unit I36LK I36CV Front Width 30 3 4 39 37 1 4 Rear Width 25 3 4 Height 25 5 8 28 3 4 27 De...

Страница 10: ...urrounds shown here are universal and can be used with the I36CV model Furthermore the I33S4535B and I36S4736B 1 piece Surround was designed to be used as a custom cutout surround Simply trace templat...

Страница 11: ...sed then fasten them to the Clean View kit with the seven 7 screws provided 4 Insert the Clean View Mounting Tab into the Clean View Mounting Slots four 4 places and lower the Clean View kit into plac...

Страница 12: ...3LK I36LK Front to the appliance by lowering it onto the side attachments aligning the four 4 Mounting Tabs and Slots together Position the tabs into the slots and then lock it into place by lowering...

Страница 13: ...the top panel into place The top panel lines up with the three 3 slots behind the top grill Secure the top panel in place with the three 3 pre set screws 5 Once the top panel is secured line up the si...

Страница 14: ...hat is constructed with materials that can withstand temperatures above 250 F 121 C Non combustible Mantels can be installed at any height above the fireplace opening and thus not restricted to the cl...

Страница 15: ...attached to the existing chimney crown clay lined chimney or wood stove vent pipe The Seal Plate of the termination may be cut notched and formed to make a good seal to the existing vent or be left fl...

Страница 16: ...ng the top of the unit in between the guides and check that it remains flat Fig 2 4 Once the unit is slid back into position use the two screws previously removed to secure the adapter plate When tigh...

Страница 17: ...rt and tighten all screws e g 1 of movement equals to 4 holes Riser Kit Installation Instructions Model No I33R40 I33R44 1 Measure height required to make flush with base of unit Fig 1 If measurement...

Страница 18: ...oves and pull towards yourself while lifting the latch slightly upwards 3 Once the top of the door is unlatched pull it outwards and up to unlatch the bottom 4 To re install place the Bottom Door Ledg...

Страница 19: ...information 2 Remove the Air Shield by removing the four 4 screws that is securing it 3 Place the Back Porcelain Panel up against the back of the Firebox and reinstall the Air Shield in front of the...

Страница 20: ...of the door frame with magnets 1 Place the Overlay over the Glass Door and insert the steel pin through to the Latch Mount Hole 2 Use magnets to secure the lower part of the Overlay Double Door Insta...

Страница 21: ...zes 6 Ports are accessible for test gauge connection both on the inlet and outlet of the gas valve 7 Turn the gas supply ON and check for leaks DO NOT USE OPEN FLAME FOR THIS PURPOSE Use an approved l...

Страница 22: ...around the outside of the burner pan This will remove the entire burner assembly 4 When removing the entire burner assembly break the seal and lift upwards Make sure the gas line to the unit has been...

Страница 23: ...or 4 When resealing the Fan Access Panel use High Temp Silicone or Millpac 1 Remove glass door assembly and log set if installed Be sure to handle logs carefully as they become fragile after heated 2...

Страница 24: ...1 38VF 119 Grate Bar 4 13 1001 P713SI LP Pilot Assembly LP 1 13 1001 P714SI NG Pilot Assembly NG 1 15 1000 255 1 8 Orifice 1 16 1000 253 1 8 x 3 4 Closed Nipple 2 17 2000 213 1 8 90 Elbow 1 18 1000 P2...

Страница 25: ...ion above on this label If you don t smell gas then go to the next step 7 Now push in the control knob slightly and turn 4 counter clockwise to the PILOT position 8 Push in the control knob all the wa...

Страница 26: ...ent that permits HI LO functionality to be controlled by the remote Contrary to this feature is a Manual HI LO Control Knob The Modulating Servo Motor requires the Remote system to be present Backup B...

Страница 27: ...Remote wiring harness use its male plug in connector and connect it to the female plug in in the main IPI harness Now the circuit is complete So the way it works is that electrical power is supplied...

Страница 28: ...Configuration 2 Remote ON OFF and manual HI LO capabilities OPTIONAL For units with remote HI LO capabilities a modulating servo is required to be installed on the valve The connectors to this servo...

Страница 29: ...tment LIGHTING INSTRUCTIONS 1 STOP Read the above safety information on this label 2 Remove batteries from Receiver and or Battery Backup Pack 3 Turn off all electric power to the fireplace 4 This fir...

Страница 30: ...oles over the 2 pins on the right side of the log mounting pan as shown in the picture above Log C has to be lowered into position just behind Logs A and B Log C shall be pulled up to Logs A and B as...

Страница 31: ...lace Log 3 onto right side of Log 1 Locate 2 holes on bottoms of Logs 4 and 5 and position onto mounting pins Locate 1 hole on the bottom of Log 6 and place it onto pin of Log 2 Locate 2 holes on the...

Страница 32: ...ght screws on the grate bar Reinstall screws after removing parts Place the MQRSP4 Rock Platform and ember plates into place as shown in the illustration above Step 1 Place Rocks 4 into position as sh...

Страница 33: ...osition as shown above Step 6 Place Rocks 1 into position as shown above Step 7 Place Rocks 3 and 4 into position as shown above Finished Rock Set and Burn NOTE If flame impingement on the rocks cause...

Страница 34: ...re is a spring clip below the pilot hood then proceed to STEP 5 in PART B on the next page 5 Remove the 2 screws that hold the pilot to the bracket 6 Remove the 2 screws that attach the pilot bracket...

Страница 35: ...the new injector is proper for the application The injector size is stamped on the side of the injector near the top LPG injectors have a groove machined around their circumference near the top while...

Страница 36: ...on Kit Natural Gas IDV33NE IPI 33IDV CKLPI Conversion Kit Liquid Propane IDV33LPE IPI IDV36 Parts List Part No Description Fireplace Base Unit IDV36N Millivolt IDV36NE IPI INSERT DIRECT VENT FIREPLACE...

Страница 37: ...002SI IPI Valve System HI LO NG 1006 P003SI IPI Valve System HI LO LP 1002 P047SI Pilot Assembly LP 1002 P033SI Pilot Assembly NG 1002 P017SI Spark Electrode with Wire 1002 P903SI Electrode Flame Sens...

Страница 38: ...tive wall switch If okay jumper wires across wall switch wires at valve If burner comes on wires are faulty or connections are bad Generator may not be generating sufficient voltage Check generator wi...

Страница 39: ...dential environment c damages caused by any unauthorized alteration or repair of the unit affecting its stability or performance d damages caused by improper matching or application of the unit or the...