Trawl Explorer | V5 | Servicing and Maintenance
1.
Replace the o-ring seals with new lubricated seals.
2.
On the new temperature sensor cables, strip the end of
each cable and crimp pins to each stripped cable.
Tip:
If you do not have the necessary tools to do
these operations on the cables, another solution is
to keep the old cables connected to the connector,
cut them at mid-length and solder the new cables
to them.
3.
Slide the cables through the temperature hole and
through the hole in the internal housing and put the new
cables into the white connector in the same order as on
the picture (view of side with clips upward).
4.
Apply loctite on the temperature screw thread, then
tighten back into place the temperature sensor with the
wrench (torque at 60 in-lbs / 7 N-m).
5.
Connect the white connector to the PCBA.
6.
Put back the end cap and reconnect components.
1.
Put back the end cap and screw with the 1/8" Allen key
(torque at 15 in-lbs / 2 N-m).
2.
Put back and reconnect the batteries.
7.
Protect the components and bottle.
A.
End cap /
B.
Transducer
1.
Main o-ring /
2.
Backup o-ring
1.
Put back into place the PCBA retainers and screw with the
1.5 mm Allen key.
2.
Replace the protective tape.
3.
Install 2 new main o-rings and 2 backup o-rings on the
end cap and transducer as illustrated (cross-section).
Inspect and fully clean the o-ring grooves.
4.
Check that all seals in the bottle are clean and lubricated.
Apply lubricant if necessary.
Replacing the Transducer
Before you begin
For this task you need the following tools:
76
Содержание Trawl Explorer
Страница 1: ...Trawl Explorer Service Manual...
Страница 2: ......
Страница 25: ...Trawl Explorer V5 Sensor Configuration 24...
Страница 68: ...Trawl Explorer V5 Servicing and Maintenance A End cap B Transducer 1 Main o ring 2 Backup o ring 67...
Страница 92: ...Trawl Explorer V5 Appendix 1 50 cm 2 1 m 3 Counterweight 91...