Features 

1.  Large  backlit  dual  display  shows  any  combination  of 
T1, T2, T1-T2 plus MAX, MIN, AVG 
2.Relative  time  clock  on  MAX  MIN  and  AVG  provides  a 
time reference for major events 
3.Electronic  Offset  function  allows  compensation  of 
thermocouple errors to maximize overall accuracy. 
4.Readout in 0C, 0 F ,or Kelvin(K) 
5. Auto Power Off mode (Sleep mode) increases battery 
life. 

 

Button 

1.Press 

to turn the thermometer on or off. 

2.Press 

to step through the maximum, minimum, 

and average readings. Whenreadings, shows the 
maximum, minimum, and average of the logged 
readings. To exit the   

MIN/MAX/AVG

mode , press the 

 button for 3 seconds to return to normal 

operation. 

3

.

Press

to switch between Celsius (

0

C), Fahrenheit 

(

F), and Kelvin (K). 

Содержание MTT-302

Страница 1: ...Thermocouple Thermometer Products Code MTT 302 User Manual WWW MARMONIX CO...

Страница 2: ...Dual input contact thermometers offer fast response and laboratory accuracy These thermometers work with K type thermocouples and offer 0 1 0 C 0 10 F resolutions...

Страница 3: ...1 TYPE K 2 TYPE K 3 Primary or Secondary Display 4 Secondary Display 5 T1 T2 T1 T2 6 UP 7 ENTER 8 DOWN 9 ON OFF 10 SETUP 11 BLACKLIGHT 12 MIN MAX AVG 13 HLOD 14 0 C 0 F K...

Страница 4: ...Noncondensing Storage Temperature 10 0 C to 500 C 140 F to 1220 F Temperature Range K type thermocouples 200 0 C to 1372 0 C 328 0 F to 2501 0 F Temperature accuracy T1 T2 Above 100 0 C 148 0 F 0 15 r...

Страница 5: ...imize overall accuracy 4 Readout in 0C 0 F or Kelvin K 5 Auto Power Off mode Sleep mode increases battery life Button 1 Press to turn the thermometer on or off 2 Press to step through the maximum mini...

Страница 6: ...econdary display 6 Press to start or exit Setup See Changing Setup Options 7 Press to scroll to the Setup option you want to change Press to increase the displayed setting 8 Press to scroll to the Set...

Страница 7: ...n progress 2 The thermocouple measurement includes anoffset See Changing Setup Options 3 The displayed readings do not change 4 Low battery Replace the batteries 5 The temperature unit 6 Primary Displ...

Страница 8: ...t connector s 2 Press to turn on the thermometer After 1 second the thermometer displays the first reading If no thermocouple is plugged into the selected input or thethermocouple is open the display...

Страница 9: ...croll to the setup option youwant to change 2 Press to indicate that you want to change thissetting 3 Press or until the setting you want to useappears on the display 4 Press to store the new setting...

Страница 10: ...r 20 minutes When the auto power off mode is forbade a letter n is show on the screen Display Elements When the thermometer is in Setup mode the displayshows SETUP Press or to scroll to the SLP page P...

Страница 11: ...The display shows when a thermocoupleis not connected The display shows 0L overload when thetemperature being measured is outside thethermocouple s valid range Holding the Displayed Readings 1 Press t...

Страница 12: ...or ProbeErrors Use the offset option in Setup to adjust the thermometer sreadings to compensate for the errors of a specificthethermocouple The allowable adjustment range is 5 0 0 C or 9 0 0 F 1 Plug...

Страница 13: ...Replacing the Batteries 1 Turn off the thermometer if necessary 2 Loosen the screw and remove the battery door 3 Replace 9V batteries 4 Replace the battery...