VITALink®
MC/RC90
Fire-Resistive Cable Certified by UL and ULC
IM-120-0
VITALink® MC/RC90 Cables
Rev 0
Systems 120/120A/60
7/31/2020
RSCC Wire & Cable LLC © 2020 • 20 Bradley Park Road • East Granby, CT 06026 USA • 800-327-7625 Tel: 860-653-8300 • Fax: 860-653-8321 •
r-scc.com
7/7
Conductor Size
(AWG/kcmil)
RSCC Cable PN
Prefix
Nom Armor
OD (In)
Nom Jacketed
OD (In)
Cable Connector PN
“WSE-WT-“ Series
Connector Hub
Hole Punch
Trade Size
Connector
Body OD
Non-Jacketed
Cable
Jacketed
Cable
6*
VM04006
1.215
1.318
125-125-S3
1-1/4”
2.12”
4*
VM04004
1.350
1.453
139-125-S3
1-1/4”
2.12”
3*
VM04003
1.410
1.513
148-150-S3
1-1/2”
2.5”
2*
VM04002
1.500
1.603
157-150-S3
1-1/2”
2.5”
1*
VM04001
1.729
1.852
175-200-S3
2”
3”
1/0*
VM041X0
1.820
1.943
184-200-S3
2”
3”
2/0*
VM042X0
1.950
2.073
202-200-S3
2”
3”
3/0*
VM043X0
2.123
2.246
213-250NJ-S3
213-250-S3
2-1/2”
3.75”
4/0*
VM044X0
2.258
2.412
235-250-S3
2-1/2”
3.75”
250*
VM04250
2.460
2.634
257-250-S3
2-1/2”
3.75”
350*
VM04350
2.710
2.864
285-300-S3
3”
4.5”
400*
VM04400
3.128
3.302
313-300-S3
3”
4.5”
500*
VM04500
3.128
3.302
313-300-S3
3”
4.5”
5 Conductor
14
VM05014
0.940
1.043
097-100-S3
1”
2”
12
VM05012
1.004
1.107
104-100-S3
1”
2”
10
VM05010
1.075
1.178
111-100-S3
1”
2”
8
VM05008
1.215
1.318
125-125-S3
1-1/4”
2.12”
6
VM05006
1.299
1.402
132-125-S3
1-1/4”
2.12”
4
VM05004
1.480
1.583
157-150-S3
1-1/2”
2.5”
3
VM05003
1.585
1.708
166-150-S3
1-1/2”
2.5”
2
VM05002
1.670
1.793
166-150-S3
1-1/2”
2.5”
1
VM05001
1.915
2.038
193-200-S3
2”
3”
1/0
VM051X0
2.038
2.161
213-250NJ-S3
213-250-S3
2-1/2”
3.75”
2/0
VM052X0
2.258
2.412
235-250-S3
2-1/2”
3.75”
3/0
VM053X0
2.460
2.614
257-250-S3
2-1/2”
3.75”
4/0
VM054X0
2.480
2.634
257-250-S3
2-1/2”
3.75”
6 Conductor
14
VM06014
1.004
1.107
104-100-S3
1”
2”
12
VM06012
1.075
1.178
111-100-S3
1”
2”
10
VM06010
1.155
1.258
118-100L-S3
1”
2”
8
VM06008
1.299
1.402
132-125-S3
1-1/4”
2.12”
6
VM06006
1.410
1.513
148-150-S3
1-1/2”
2.5”
4
VM06004
1.585
1.708
166-150-S3
1-1/2”
2.5”
7 Conductor
14
VM07014
1.004
1.107
104-100-S3
1”
2”
12
VM07012
1.075
1.178
111-100-S3
1”
2”
10
VM07010
1.155
1.258
118-100L-S3
1”
2”
8
VM07008
1.299
1.402
132-125-S3
1-1/4”
2.12”
6
VM07006
1.410
1.513
148-150-S3
1-1/2”
2.5”
8 Conductor
14
VM08014
1.155
1.258
118-100L-S3
1”
2”
12
VM08012
1.215
1.318
125-125-S3
1-1/4”
2.12”
10
VM08010
1.299
1.402
132-125-S3
1-1/4”
2.12”
8
VM08008
1.500
1.623
157-150-S3
1-1/2”
2.5”
9 Conductor
14
VM09014
1.215
1.318
125-125-S3
1-1/4”
2.12”
12
VM09012
1.299
1.402
132-125-S3
1-1/4”
2.12”
10
VM09010
1.410
1.513
148-150-S3
1-1/2”
2.5”
10 Conductor
14
VM10014
1.215
1.318
125-125-S3
1-1/4”
2.12”
12
VM10012
1.299
1.402
132-125-S3
1-1/4”
2.12”
10
VM10010
1.410
1.513
148-150-S3
1-1/2”
2.5”
12 Conductor
14
VM12014
1.235
1.338
125-125-S3
1-1/4”
2.12”
12
VM12012
1.350
1.453
139-125-S3
1-1/4”
2.12”
10
VM12010
1.410
1.513
148-150-S3
1-1/2”
2.5”
*
Segmented groundwires available
Note: Non-Fire Rated Connectors will be sized similarly but do not have to be stainless steel.