SD833
4
1. Open the cover by lifting the opening tab while firmly holding the base with
your other hand.
2. Install a 9V battery into the detector’s battery snap.
See 5.b Placing the
battery
3. Insert the Test jumper; the SD833 enters Test mode and the LED flashes
every few seconds.
4.
From the Programming menu, select
Devices, Zones
[911].
5. Select the zone to which you want to register the transmitter; the system
initiates Registration mode. When
Save?
appears on the panel’s
LCD
display, press
9
.
6. After registration, remove the Test jumper and place it over one pin for
storage.
5. MOUNTING
a.
Attaching to Ceiling or Wall.
The Smoke Detector is battery operated and needs only wiring, if the Inter-connect
facility is being used.
1. Before permanently mounting the unit, test the transmitter from the exact
mounting position.
2.
Pull cover open at tab.
3. Place the base on ceiling or wall exactly where you want to mount the unit.
With a pencil, mark the location of the screw holes.
OPEN TAB
BATTERY
INSTALLATION
DATE
SCREW HOLE
TEST
BUTTON
SCREW HOLE
CHAMBER LABEL
BATTERY
PUSH BACK TO EASE
BATTERY REMOVAL
Figure 1
TEST JUMPER