Replacing the fuse after melt-through.
Replacing the fuse is possible without opening the module! (if
the module has been opened the guarantee no longer applies).
Remove the film above the fuse and then pull the fuse out of the
module with pointed pliers.
Replace the fuse with a fuse of one of the following types (with
the application of other types the guarantee no longer applies):
Supplier dimmer fuse
Description
Order number supplier
Littelfuse LT-5
ALg
0663.01.6
Bussman
ETF Radial Lead Micro Fuse
BK ETF1.6
ELU
Sub miniature fuse links
166050-1,6AT
Wickmann
Subminiatur fuse No 372.TR5
372-1160-041
Bel fuse
Time Lag Radial Lead Micro Fuse
MTR1,6 short leads
NEVER CONNECT A WOUND VOLTAGE TRANSFORMER TO THE
LWM1 WHILE THE VOLTAGE IS SWITCHED ON. THE FUSE CAN
MELT AS A RESULT.
LOW VOLTAGE HALOGEN LIGHTING
The LWM1 can only be used in combination with the electronic
transformer suitable for leading-edge phase dimmers. The LWM1
cannot be coupled to transformers suitable for trailing-edge
phase dimmers. Coupling it to such a transformer will cause a
humming sound and damage the LWM1. The right to guarantee
will also expire as a result.
14