MGTE 1-1/2” METERED & TIMECLOCK
OPERATION
13
Phone: (262) 681-1300 • Web: www.Marlo-Inc.com • E-mail: [email protected]
“MGTE” Series Automatic Water Conditioners
14
8-192 R1
Settings Options Table 8
Volume
Capacity
Regeneration
Time Option
Day
Override
Result4
AUTO
DELAYED
REGEN
OFF
Reserve capacity automatically estimated.
Regeneration occurs when volume capacity falls below the reserve capacity at
the next Regen Set Time
AUTO
DELAYED
REGEN
Any
number
Reserve capacity automatically estimated.
Regeneration occurs at the next Regen Set Time when volume capacity falls
below the reserve capacity or the specified number of days between
regenerations is reached.
Any
number
DELAYED
REGEN
OFF
Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when volume capacity reaches
0.
OFF
DELAYED
REGEN
Any
number
Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when the specified number of
days between regenerations is reached.
Any
number
DELAYED
REGEN
Any
number
Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when volume capacity reaches
0 or the specified number of days between regenerations is reached.
AUTO
IMMEDIATE
OFF
Reserve capacity not automatically estimated.
Regeneration occurs immediately when volume capacity reaches 0. Time of
regeneration will not be allowed to be set because regeneration will always occur
when volume capacity reaches 0.
Any
number
IMMEDIATE
OFF
Reserve capacity not automatically estimated.
Regeneration occurs immediately when volume capacity reaches 0. Time of
regeneration will not be allowed to be set because regeneration will always occur
when volume capacity reaches 0.
AUTO
DELAY +
IMMEDIATE
OFF
Reserve capacity automatically estimated.
Regeneration occurs when volume capacity falls below the reserve capacity at
the next Regen Set Time or regeneration occurs after 10 minutes of no water
usage when volume capacity reaches 0.
AUTO
DELAY +
IMMEDIATE
Any
number
Reserve capacity automatically estimated.
Regeneration occurs at the next Regen Set Time when volume capacity falls
below the reserve capacity or the specified number of days between
regenerations is reached or regeneration occurs after 10 minutes of no water
usage when volume capacity reaches 0.
Any
number
DELAY +
IMMEDIATE
Any
number
Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when the specified number of
days between regenerations is reached or regeneration occurs after 10 minutes
of no water usage when volume capacity reaches 0.
4 Reserve capacity estimate is based on history of water usage
SETTING OPTIONS TABLE 8