![Marlo Incorporated MGTE Series Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/marlo-incorporated/mgte-series/mgte-series_installation-operation-and-maintenance-manual_1729700012.webp)
MGTE 1-1/2” METERED & TIMECLOCK
OPERATION
10
Phone: (262) 681-1300 • Web: www.Marlo-Inc.com • E-mail: [email protected]
“MGTE” Series Automatic Water Conditioners
8
8-192 R1
Regeneration Mode
Typically a system is set to regenerate at a time of low water usage. An
example of a time with low water usage is when a household is asleep. If
there is a demand for water when the system is regenerating, untreated water
will be used.
When the system begins to regenerate, the display will change to include
information about the step of the regeneration process and the time remaining
for that step to be completed. The system runs through the steps
automatically and will reset itself to provide treated water when the
regeneration has been completed.
Manual Regeneration
Sometimes there is a need to regenerate the system sooner than when the
system calls for it, usually referred to as manual regeneration. There may be
a period of heavy water usage because of guests or a heavy laundry day. To
initiate a manual regeneration at the preset delayed regeneration time, when
the regeneration time option is set to “DELAYED REGEN” or “DELAY +
IMMEDIATE”, press and release “REGEN”.
The words “REGEN TODAY” will periodically be shown
on the display to indicate that the system will regenerate
at the preset delayed regeneration time. If you pressed
the “REGEN” button in error, pressing the button again
will cancel the request.
Note: If the regeneration time option is set to “IMMEDIATE” there is no set
delayed regeneration time so “REGEN TODAY” will not activate if “REGEN”
button is pressed. To initiate a manual regeneration immediately, press and
hold the “REGEN” button for three seconds. The system will begin to
regenerate immediately. The request cannot be cancelled. Note: For
softeners, if brine tank does not contain salt, fill with salt and wait at least two
hours before regenerating.
Set Time of Day
The user can also set the time of day. Time of day should only need to be set
if the battery has been depleted because of extended power outages or when
daylight saving time begins or ends. If an extended power outage occurs, the
time of day will flash on and off which indicates the time of day should be
reset. The non rechargeable battery should also be replaced.
STEP 1U
– Press CLOCK
STEP 2U
- Current Time (hour): Set the hour of the day using DOWN or UP.
AM/PM toggles after 12. Press NEXT to go to Step 3U.