“CMP” & “C” Series Automatic Water Conditioners
Regeneration Mode
Typically a system is set to regenerate at a time of low water usage. An example of a
time with low water usage is when a household is asleep. If there is a demand for water
when the system is regenerating, untreated water will be used.
Set Time of Day
The user can also set the time of day. Time of day should only need to be set after
extended power outages or when daylight saving time begins or ends and at the time
of start-up. If an extended power outage occurs, the time of day will flash on and off
which indicates the time of day should be reset.
STEP 1U
- press SET CLOCK.
STEP 2U
- Current Time (hour): Set the hour of the day using or buttons.
AM/PM toggles after 12. Press NEXT to go to step 3U.
STEP 3U
- Current Time (minutes): Set the minutes of the day using or
buttons. Press NEXT to exit Set Clock. Press REGEN to return to previous step.
Power Loss
If the power goes out for
less than two hours
, the system will automatically reset itself. If an extended power outage
occurs, the time of day will flash on and off which indicates the time of day should be reset. The system will retain the
other information entered by the installer.
When the system begins to regenerate, the display will change to include information about the step of the regeneration
process and the time remaining for that step to be completed. The system runs through the steps automatically and will
reset itself to provide treated water when the regeneration has been completed.
Manual Regeneration
Sometimes there is a need to regenerate the system,
sooner than when the system calls for it, usually referred to
as manual regeneration. There may be a period of heavy
water usage because of guests or a heavy laundry day.
To initiate a manual regeneration at the preset delayed regeneration time, press and release “REGEN”. The words
“REGEN TODAY” will flash on the display to indicate that the system will regenerate at the preset delayed regenera-
tion time. If you pressed the “REGEN” button in error, pressing the button again will cancel the request. Note: If the
regeneration time option is set to “on 0” there is no set delayed regeneration time so “REGEN TODAY” will not activate
if “REGEN” button is pressed.
To initiate a manual regeneration immediately, press and hold the “REGEN” button for three seconds. The system will
begin to regenerate immediately. The request cannot be cancelled.
Note: For softeners, if brine tank does not contain salt, fill with salt and wait at least two hours before regenerating.
Error Message
If the word “ERROR” and a number are alternately flashing on the display contact the Installer for help. This indicates
that the valve was not able to function properly. Refer to “Troubleshooting” for “ERROR RESET” procedure.
P.M.
P.M.
REGEN TODAY will
show if a regeneration
is expected “Tonight.”
REGEN
TODAY
CAPACITY
REMAINING
GAL
REGEN
BACKWASH
SET TIME
Step 2U
SET
CLOCK
NEXT
REGEN
6:35
Step 3U
SET
CLOCK
NEXT
REGEN
6:35
SET TIME
SET
CLOCK
NEXT
REGEN
Step 1U
Error
1003
2 8:22
320
SET
CLOCK
NEXT
REGEN
8-171 R5