MD5016 Field Installation
08-1612 SECTION-4 PAGE 5 OF 6
Belt Drive - Field Installed Motor
Belt Installation
SHEAVE ALIGNMENT
BELT INSTALLATION
BELT:
The number of grooves on the sheaves and the number of
ribs on th belt may vary. Always install the belt on the
highest grooves of the sheaves
GALVANIZED
STAINLESS STEEL
(UNLUBRICATED)
(UNLUBRICATED)
10mm
30-32 (42-43)
34-36 (46-48)
12mm
64-66 (87-90)
85-90 (115-122)
16mm
135-140 (183-190)
125-130 (169-176)
20mm
220-230 (298-312)
195-205 (264-278)
FASTENER TORQUE
FOOT-POUNDS (NEWTON-METERS)
BOLT
DIAMETER
FASTENER TORQUE @ MOTOR ONLY
Align the top edges of the fan and motor
sheaves while ensuring that both are fully
engaged on their shafts. There should be 4
points of contact when a straight edge is
layed across the top of both sheaves.
FAN SHEAVE
MOTOR SHEAVE