Marley Geareducer 32.2 Скачать руководство пользователя страница 5

 5

Changing Geareducer Oil 

Drain the Geareducer oil by removing the drain plug. See  

Figure 2 

for location. If equipped with an external dipstick/oil 

level gauge, remove the drain plug at that location, and drain the 
entire system.
When using synthetic oil with extended service intervals remove a 
sample for lab analysis and look for evidence of foreign material, 
such as water, metal shavings or sludge. If you find unacceptable 
condensation or sludge, flush the Geareducer with mineral oil 
before refilling. 
The horizontal part of the oil line must be level or slightly lower at 
the oil level gauge than at the Geareducer. The oil capacity of the 

32.2 Series Geareducer: 9 gallons (

34 liters)

 The oil level gauge line requires approximately one additional 
gallon of oil. Refer to back cover for suggested lubricants. If the 
Geareducer is equipped with an external dipstick/oil level gauge 
an additional 3 to 4 quarts of oil will be required. Be certain that 
the vent on the Geareducer (and external dipstick/oil level gauge, 
if present) is not plugged. Verify that the gauge/drain line is full 
and that there aren’t any leaks at the connections.

Figure 2 

Oil Gauge and Drain Line

 

(Series 36 Geareducer is illustrated)

operation and service  

Fill the Geareducer and oil line system with oil, using one of the 
following procedures:
Recommended procedure:
1.  Install oil at the opening at the Geareducer inspection cover.

Full is the center of the sight glass. If oil is 

not

 visable in the 

sight glass then oil needs to be added . See 

Figures 3

 and 

4

Install  plug.

2.  Start the fan drive and run for one minute.
3.  Stop the fan drive. Allow ten minutes for oil level to stabilize 

and recheck oil level at the Geareducer.

4.  If necessary, repeat steps 2 and 3 until stabilized oil level is at 

the proper level.

5.  Check gauge placard location. Full mark on the placard must 

be at the same elevation as the Full mark at the Geareducer.

Alternate procedure:
The cooling tower has an external oil gauge and drain line equipped 
with a three-way valve below the oil level gauge. See 

Figure 3

.

1.  Remove pipe plug. Turn valve control stem clockwise to open 

drain.

2.  With Geareducer drained, the three-way valve turned clockwise, 

and the pipe plug removed, connect fill source (usually a hose 
to a pump, to the three-way valve).

  Pump oil through the hose. Check oil level occasionally by 

turning the valve control stem counterclockwise and allowing 
the oil level in the sight glass to stabilize.

  Continue filling until full level mark is reached.
3.  With the oil level at the full mark turn the valve control stem 

counterclockwise to close the drain and open the valve to the 
sight glass. Remove the oil filling line and reinstall pipe plug in 
the three-way valve.

VENT

OIL LEVEL

GAUGE

OIL LEVEL

PLACARD

FULL

ADD

OIL

NOTICE

CHECK OIL LEVEL TEN

MINUTES AFTER

FAN STOPS ROTATING

FILL AT GEAREDUCER

REFER TO SERVICE MANUAL

FOR OIL CHANGE AND

MAINTENANCE RECOMMENDATIONS

SPX COOLING TECHNOLOGIES

OVERLAND PARK, KS  USA

92-110A

Figure 3 

Sight glass gauge assembly

Содержание Geareducer 32.2

Страница 1: ...Geareducer model 32 2 INSTALLATION OPERATION MAINTENANCE Z0238997_C ISSUED 06 2022 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT user manual ...

Страница 2: ...dded via the filler neck or pumped in through the drain connection this lubricant will not reduce the overall level of protection however if the unit is operated for any amount of time the Pre Commission period is depleted and the unit is now considered to be in Operational status Check the Geareducer exterior yearly Touch up with paint as required Exposed pipe threads are coated to prevent corros...

Страница 3: ... of Geareducer and connecting oil line Also at this time observe the contact pattern of the gear teeth to see if they appear as illustrated in Detail A and B If incorrect gear tooth pattern should occur refer to Marley Field Repair Manual for Series 32 2 Geareducer operation and service Figure 1 Priming Interstage Shaft Check all gasketed joints for oil seepage Tighten cap screws and flange boltin...

Страница 4: ...4 Detail A Spiral Bevel Gear Tooth Pattern Detail B Helical Gear Tooth Pattern operation and service ...

Страница 5: ...n cover Full is the center of the sight glass If oil is not visable in the sight glass then oil needs to be added See Figures 3 and 4 Install plug 2 Start the fan drive and run for one minute 3 Stop the fan drive Allow ten minutes for oil level to stabilize and recheck oil level at the Geareducer 4 If necessary repeat steps 2 and 3 until stabilized oil level is at the proper level 5 Check gauge pl...

Страница 6: ...dd oil if required noting the addition in your maintenance log If equipped with an external dipstick oil level gauge small quantities of oil can be added at that location Semi annually If using turbine type mineral oil change oil see Changing Geareducer Oil for instructions Check that all the assembly bolts and cap screws are tight that oil plugs and pipe connections are in place and free from lea...

Страница 7: ...aul your Geareducer refer to the Field Repair Section and Geareducer Parts List Suggested Lubricants The following list of lubricants in Table 1 is provided as reference only These products have been recommended by their respective manufacturers as acceptable for use in a Marley spiral bevel and or helical Geareducer for cooling tower applications This list is not an attempt to include all the lub...

Страница 8: ...IES In the interest of technological progress all products are subject to design and or material change without notice Geareducer 32 2 US E R MAN UAL SPX COOLING TECH LLC 7401 WEST 129 STREET OVERLAND PARK KS 66213 USA 913 664 7400 spxcooling spx com spxcooling com ...

Отзывы: