background image

(Optional)

Installation of Back Box With

Surface-Mounting Frame

(See Figure 3).

1. Secure back box to wall (with knockouts in upper right

hand corner) using screws and anchors.

2. Hang the surface-mounting frame on the back box.

Ensure that the back edge of the surface-mounting

frame is flush against the wall.

NOTE:

If heater is located in a high traffic area where it may

be subjected to vandalism or abuse, take extreme care to see

that the box is firmly attached to the wall.

3. Power Supply Wiring

NOTE:

Wiring Compartment Volume - 119"3 (1950cm3).

a. Run a power supply cable into the area of the upper

right corner of the mounting frame. All wiring must be in

accordance to National and local Electrical Codes.

Refer to Table 1 for proper wire sizes.

NOTE:

If the wiring is to run through the wall, cut a hole in the

wall near the top of the back box. Run the supply wire

through this hole. Then remove the knockout from the top of

the box and proceed to step c.

b. Remove the knockout on the top side of the frame.

c. Feed the power supply cable through the frame allow-

ing 6" (152mm) of lead to remain inside the frame

d. Secure the power supply cable to the back box

(using cable clamps, connector, or other suitable strain

relief) allowing 6”(152mm) of lead to remain inside the

inner housing.

e. Ground the back box by connecting the supply ground

leadwire to the green ground screw located in the

inside top of the back box.

Installation of Heater Assembly and Grille

After back box is completely installed and no further con-

struction dirt is expected, clean debris from back box, remove

heater assembly from its carton, then refer to Figure 4 and

proceed as follows:

1. Insert the heater assembly into back box, placing

the four mounting holes (with key-hole slots) over the

screws in the back box. Tighten all screws securely.

2. If surface-mounting frame is used, ensure that the

frame is even with all four heater assembly tabs before

tightening screws.

3. Connect the lead wires from the disconnect switch to

the lead wires from the fan deck. (See wiring diagrams)

After connection, push wires back into opening.

4. Turn thermostat to the extreme counterclockwise

position.

5. Mount the grille using four (4) long screws provided.

The screws thread into holes located in the side

flanges of the back box.

6. Push thermostat knob onto thermostat shaft.

Operation

1. Turn power to heater on at main switch panel. Rotate the

thermostat knob fully clockwise. This should energize the

heating elements and the fan, causing air to flow from the

air discharge at the openings in the bottom of the grille.

2. After the discharge air has become warm, rotate the

thermostat knob to the desired position to obtain room

comfort.

NOTE:

For best results, the heater should be left ON con-

stantly during the heating season since the thermostat, when

properly set, will maintain the desired temperature.

IMPORTANT INFORMATION

Maintenance

TO RESET MANUAL RESET LIMIT

Your heater is equipped with a manual reset safety thermal

limit control that will automatically turn the heater off to pre-

vent a fire if the heater overheats. This control is located on

the fan panel assembly between the element and fan blade

and marked “reset.” The red reset button can be seen

through the front grille when the heater is installed. To reset,

allow the heater to cool, then push the red button that is vis-

ible through the hole in the fan panel. The heater should

immediately return to normal operation.

Fig. 3: Surface Mounting Installation

Fig. 4

HANG FRAME

ON BACK BOX

15-5/32"

(385mm)

19"

(482mm)

3-13/16"

(97mm)

MOUNT BACK BOX TO

WALL USING REAR

MOUNTING HOLES.

3

POWER

LEADS

RECESS BACK

BOX

HEATER

ASSEMBLY

THERMOSTAT

KNOB

GRILLE

4000 & 3000 WATT HEATERS

Full wattage heaters can be converted to half wattage by removing the red

jumper wire connecting the top and bottom element terminals.

WIRING DIAGRAMS

(ALL 1Ø)

DISCONNECT

CAUTION

OPERATION OF THE MANUAL RESET SAFETY THERMAL

LIMIT CONTROL IS AN INDICATION THAT THE HEATER HAS

BEEN SUBJECTED TO SOME ABNORMAL CONDITION. IT

IS RECOMMENDED THAT THE HEATER BE CHECKED BY A

REPUTABLE ELECTRICIAN OR REPAIR SERVICE TO

ENSURE THE HEATER HAS NOT BEEN DAMAGED.

!

Содержание FZL Series

Страница 1: ...combustible materials such as crates drapes etc away from heater Do not install behind doors furniture towels or boxes 7 A heater has hot and arcing sparking parts inside Do not use it in areas where gasoline paint or flammable liquids are used or stored 8 Use this heater only as described in this manual Any other uses not recommended by the manufacturer may cause fire electric shock or injury to ...

Страница 2: ...19 3 1950cm3 a Run a power supply cable into the area above the top of the wall opening All wiring must be in accordance with National and local Electrical Codes Refer to Table 1 for correct wire size b Install a cable clamp in the knockout in the top of back box c Insert power supply cable through cable clamp allow ing at least 6 152mm of cable length to remain inside the back box to facilitate c...

Страница 3: ...m the disconnect switch to the lead wires from the fan deck See wiring diagrams After connection push wires back into opening 4 Turn thermostat to the extreme counterclockwise position 5 Mount the grille using four 4 long screws provided The screws thread into holes located in the side flanges of the back box 6 Push thermostat knob onto thermostat shaft Operation 1 Turn power to heater on at main ...

Страница 4: ... Engineered Products THE ABOVE WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED AND ALL IMPLIED WARRANTIES OF MER CHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH EXCEED THE AFORESAID EXPRESSED WARRANTIES ARE HEREBY DISCLAIMED AND EXCLUDED FROM THIS AGREEMENT MARLEY ENGINEERED PRODUCTS SHALL NOT BE LIABLE FOR CONSEQUENTIAL DAMAGES ARISING WITH RESPECT TO THE PRODUCT WHETH...

Отзывы: