OPERATING INSTRUCTIONS 

MODELS: 12003, 12008, 12012, and 27708

READ CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE, OR SERVICE ADJUSTABLE 
SPEED CONTROLS!
RETAIN INSTRUCTIONS FOR FURTHER REFERENCE.

Description

Leading Edge  solid state adjustable speed controls are
engineered  and  designed  specifically  for  use  with
Leading  Edge  commercial/industrial  ceiling  fans.
Controls provide adjustable speed operation at any point
between minimum and maximum fan speeds. All models
have  a  hard  plastic  backing  to  protect  components  and
circuit board and dial on/off switch. 3 Amp control Model
features brushed aluminum wall plate. 8 and 12 Amp con-
trols  feature  a  finned  aluminum  heat  sink  plate,  wire
brushed  gold  finish  and  black  trim.  All  models  are  UL
Listed.

General Safety Information

WARNING:  DISCONNECT  POWER  SUPPLY  BEFORE
WIRING  CONNECTIONS  ARE  MADE  TO  PREVENT
POSSIBLE  ELECTRICAL  SHOCK  OR  DAMAGE  TO
EQUIPMENT.

WARNING:  READ  AND  FOLLOW  INSTRUCTIONS
CAREFULLY. FAILURE TO COMPLY WITH INSTRUC-
TIONS  COULD  RESULT  IN  FIRE,  ELECTRICAL
SHOCK, INJURY TO PERSONS, AND/OR DAMAGE TO
EQUIPMENT.

1. All  wiring  should  conform  to  the  National  Electrical

Code and local regulations.

2. Do not mount in an area which will allow the control

to come in contact with moisture.

3. Make certain the entire installation is grounded as a

precaution against possible electrical shock.

4. Do not exceed maximum amperage rating of the

control as overloading can result in damage to
ceiling fan and control.

Adjustable Speed

Controls

Models    12003

Models    12008

27708

Models    12012

3 Amps

8 Amps

12 Amps

MODEL 

NUMBER

12003
12008

12012

3

10
12

AMPS

3
8

12

VOLTS

120
120
120

2
6

10

2
6

10

1
4
8

SPECIFICATIONS AND
RECOMMENDED CONTROL
CALCULATIONS PER FAN MODEL

ECR 40490

12/16

5200-2405-00

3

CONTROLS

36"/120

36201A

UNITS

CONTROLS

48

"/120

48201A; 48201BA

UNITS

CONTROLS

56

"/120

56001A; 56001BA;

56001LCA; 

56011A; 56111A; 

56301RDP; 

56101A; 56201A

UNITS

CONTROLS

56

"/

220/277

56007A

UNITS

6

CONTROLS

60

"/

120

60001A; 

60111A; 

60101A

UNITS

27708

277

8

60

011

A