![Marksman MCU-100N Скачать руководство пользователя страница 68](http://html1.mh-extra.com/html/marksman/mcu-100n/mcu-100n_user-manual_1729324068.webp)
68
General maintenance
u
Use the dry air without the high moisture
u
Check the putting to earth ground
u
Check the connection of connector
u
Be careful of the trespass of paint, metal chip & dust into MCU
u
Checking the exhaust fan & filter
u
Increase of misprint, check in the pin assembly
Servicing the Marksman
When Marking machine doesn`t work :
Symptom
Checklist
The lamp on the front panel doesn`t ON
Check the electric of main power (100V
–
220V)
All functions are working well but it doesn`t mark
after giving the start signal.
In case there`s the value to MARK UP
TO[00000000]on F2 (Refer to Pg11 F2 mode)
STATUS [ X-DRV. FAULT] Comes out
It is the problem of X-axis of Stepping driver or
motor. Or breaking of a wire for X-axis motor.
STATUS [Y-DRV. FAULT] Comes out
It is the problem of Y-axis of Stepping driver or
motor. Or breaking of a wire for Y-Axis motor.
STATUS [@G@>Input] Comes out
Entered data is less than set of digit when ASCII
code is input.
STATUS [@G@<Input] Comes out
Entered data is more than set of digit when ASCII
code is input..
STATUS [LIMIT ERROR] Comes out
Home sensor is detected during the marking.
-> Set the value of X and Y more than current
value.
Or check the direction of marking.(A:000)
If the LCD displays the misspell or the cursor moves by one self
:
Symptom
Checklist
If the LCD displays the misspell or the cursor
moves by one self
If
“
Caps Lock
”
is ON on the keyboard, it may
malfunction.
In case letter on LCD is broken and doesn`t work
correctly.
In case there`s no letter on the LCD display
Please clear all memory on the front panel, and
input the data and start the machine again. Still
have a problem, please contact our distributor.
Содержание MCU-100N
Страница 8: ...8 F1 MANUAL MARK MODE...
Страница 10: ...10 F2 AUTO MARK MODE...
Страница 35: ...35 F4 DATA MODE...
Страница 39: ...39 F5 SETUP MODE...
Страница 47: ...47 F6 TEST MODE...
Страница 49: ...49 F7 FILE LODE MODE...
Страница 52: ...52 F8 COMMUNICATION MODE...
Страница 59: ...59 How to Create PLT file by standard AUTO CAD 2006...
Страница 73: ...73...
Страница 79: ...79...
Страница 80: ...80...
Страница 81: ...81 etc Sheet material O MODEL DWG NO Description item Quantity JEIL MTECH CO LTD 2003 2 13 Edition MCU 100D...
Страница 94: ...94 How to Modify the data of block and modify the time of the controller...