MARKS USA i-Qwik LITE Series Скачать руководство пользователя страница 7

Marks USA 

• www.marksusa.com • 631-225-5400 • 800-526-0233 • Fax: 631-225-6136 • 

© 2009, Marks USA

 

 

 

Yellow 

Black 

BATTERY  INFORMATION

 

THE i-QWIK LITE IS SHIPPED WITH 4 

“AA” ALKALINE BATTERIES: 

The life span of the batteries has been tested in two different ways. The first test was performed to 

see how many operations could be performed repeatedly before a failure. The test averaged 150 thousand operations. The second test was performed over time for normal 
operations. This test revealed that the i-Qwik LITE batteries would last approximately 4 years at 80-90 thousand operations. Using the factory settings, the lockset is set for 
optimized power usage. 

CHANGE THE BATTERIES: 

The batteries should not be disconnected longer than 10 minutes or there is a risk of affecting the lock's memory. 

IT IS RECOMMENDED TO USE ONLY ALKALINE BATTERIES: 

The alkaline battery has a gradual curve in the drop off voltage. This curve determines the power settings for 

the two stages of battery warnings and the Fail Secure settings. A lithium battery differs from an alkaline battery in the life cycle of the battery cell. A lithium battery has a very 
sharp drop off voltage, going from fully charged to a dead cell quickly. This makes monitoring the voltage settings impossible. 

TWO STAGE LOW BATTERY WARNING: 

The i-Qwik LITE has a two-stage low battery warning. The first warning stage will add a double beep and Red LED when the user 

enters their code. The second warning stage will be a double beep every hour. BATTERIES SHOULD BE CHANGED IMMEDIATELY. Double beeps will occur until the 
batteries fail. 

 

CONNECTION  DIAGRAM

 

 

 

 

RESET THE LOCK

 

 

Reset The i-Qwik LITE Back To Factory Default:

 

• Open battery cover (top of housing on inside of door) 
• Disconnect the batteries 
• Locate the Yellow and Black cable (behind battery pack) 
• Insert both ends of the reset wire (or paper clip) into the holes of the connector on the yellow and black cable. 
• With the reset wire in place, reconnect the batteries. (The LED will go GREEN) 
• Press the # key (The LED will go RED and then back to GREEN) 
• Remove the reset wire 
• The lock is now reset 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание i-Qwik LITE Series

Страница 1: ...PROGRAMMING GUIDE MARKS USA 365Bayview Ave Amityville NY 11701 631 225 5400 1 800 526 0233 Fax 631 225 6136 ...

Страница 2: ... Groups Page 1 To Add Users Page 1 To Delete Users Page 1 Pin Only Entry Page 2 Change User Pin Page 2 Define Open Time Page 2 Lock Audio Page 2 Terminator On Off Page 2 Manual Passage Mode Page 3 Temporary User Schedule Page 3 Set Time Page 3 Set Date Page 3 Double Code Entry Page 3 Privacy Mode Secretary Mode Page 4 Disable Enable Three Strike Lockout Page 4 Clear Memory Page 4 Battery Check Sta...

Страница 3: ...ithin 5 seconds CREATE MASTER CODE This code is required to perform all programming functions The number of digits used for the User ID and PIN of each additional usermustbethesameastheMasterCode Enter 9991234 UserID PIN UserIDandPINfollowedby willopenthelock GROUPS ALL USERS MUSTBE ASSIGNED TO A GROUP Users in the same group will have the same access rights Eachgroupisassigneda2digitgroupnumberfr...

Страница 4: ...illstayunlockedafteravalidUsercodehasbeenentered Theopentimecanbesetfrom1to9seconds Defaultsettingis3seconds Enter MASTER CODE 18 SingleDigit1 9Seconds LOCK AUDIO Whentheaudioissetto ON thelockwillbeepwitheachkeypressed Onbydefault AUDIO OFF Enter MASTER CODE 34 0 AUDIO ON Enter MASTER CODE 34 1 TERMINATOR ON OFF This function will switch the Terminator On or Off Selecting off automatically sets l...

Страница 5: ...ned or access repeats annually This function requires setting the date in the lockset see Set Date below Enter MASTER CODE 06 UserID MMDD Start Date MMDD EndDate SETTIME Thisfunctionwillsetthetime HHMM Timeissetin24hourformat Example 3 30pm 1530 Enter MASTER CODE 12 HHMM Daylightsavingstimeisenabledbydefault Todisabledaylightsavingsadda 0 zero attheendofthetimeentry Example 3 30pm 15300 SET DATE T...

Страница 6: ...e to 40 seconds maximum Disabling this feature allows an unlimited number of incorrect codes to be entered without a lockout DISABLE Enter MASTER CODE 40 0 ENABLE Enter MASTER CODE 40 1 CLEAR MEMORY If it becomes necessary to reset the memory of the i Qwik LITE there are two options other than the Full Reset option DELETEALLUSERS SCHEDULES Enter MASTER CODE 16 16 0 DELETE ONLY SCHEDULES Enter MAST...

Страница 7: ...rve determines the power settings for thetwostagesofbatterywarningsandtheFailSecuresettings Alithiumbatterydiffersfromanalkalinebatteryinthelifecycleofthebatterycell Alithiumbatteryhasavery sharp drop off voltage going from fully charged to a dead cell quickly This makes monitoring the voltage settings impossible TWO STAGE LOW BATTERY WARNING The i Qwik LITE has a two stage low battery warning The...

Страница 8: ... product line templatesandmanuals visitourwebsite www marksusa com For i Qwik i Que Tech Support Call Toll Free 800 526 0233 In N Y 631 225 5400 Fax 631 225 6136 LIVE TECH SUPPORT 8am to 8pm EST Mon Fri Email techsupport marksusa com IP101 IQWIKLITE 03 09 2009 MARKSUSA Distributed by ...

Отзывы: