Operation
2.3 Setting the Running
Characteristics
1. Removing the roof
(unscrew whistles, push the roof
back and then remove. => Page 39).
2. You can change the locomotive’s
running characteristics by changing
the settings for the potentiometers
on the lower circuit board. These
potentiometers have a stop at the
end positions. When you encounter
resistance when turning the “pots”,
do not try to turn them further with
force.
P1: Acceleration/braking delay
(together)
Left stop:
minimum delay
Right stop: maximum delay
P2: Maximum speed
Left stop:
lowest maximum speed
Right stop: highest maximum speed
Important:
Do not confuse the two potentio-
meters for setting the running cha-
racteristics on the lower digital cir-
cuit board with the potentiometer
for adjusting the volume of the
sound effects on the upper circuit
board.
P2
P1