background image

METALS, ALLOYS & PLATINGS

ELECTROLYTE

               FOR

       NORMAL ETCH

POWER UNIT 

SETTING

COLOR

 OF MARKELECTROLYTE

            FOR 

            DEEP ETCH *

COMMENTS

Aluminum (most alloys)

Aluminum with high magnesium or silica

Aluminum (to be anodized)

Aluminum Bronze

Beryllium

Beryllium Copper

Black Oxide on Steel

Black Oxide on Stainless

Black Phosphate

Brass & Bronze

Cadmium Plate on Steel

Carbides

Chrome Plate-hard

Chrome Plate-decorative

Cobalt Alloys, Stellites

Copper & alloys

Copper Nickel ( cupro-nickel)

Damascus

Discaloy

Dow coating  (Parkerized)

Electroless Nickel Plate

Gold and Gold Plate

Gold and Gold Plate

Hastelloy

Haynes 25  (Stellite)

Haynes 188

Inconnel

Inconnel 718 & 750

Invar

Iron

Lead and alloys

Magnesium & alloys

Molybdenum

Monel & K Monel

Nickel & alloys

Nickel Plating on Brass & Copper

Nickel Plating on Steel & Aluminum

Nickel  Silver

Niobium

Nitraloy

Silver & Sterling

Silver Plate

Sintered Copper Tin

Stainless Steel (300 & 400 series)

Steels-low carbon & mild

Steels-high alloy, tool & saw steel

Tin & Tin Plate

Titanium

Titanium Nitrate

Tungsten (pure)

Tungsten Carbide

Waspaloy

Zinc & Zinc Plate

Zirconium

A10

MSC1, MSC5

B20, B10

B20, MSC7, F10

B20

MSC3, F30

MSC1

F30

B20, MSC5, B10

MSC5,B20, B10, F20

C30, C10, MSC4

MSC1, MSC7

MSC1, MSC4, MSC7

MSC1, F10, F30, MSC7

B20,B10,MSC3,MSC5

MSC5, F30, F20, B20

C10 , MSC4

MSC4, F30

MSC7 OR F30

MSC1, F10, C10

MSC4, MSC3, F20

MSC7, MSC1,MSC4

MSC5, F10

MSC4, C10, F20

MSC4, F30, F10

MSC4, MSC7, MSC1,F30

MSC4, F10

MSC3, F30

MSC5, MSC1

F10, C10

MSC1, C10

MSC7, F30

MSC7, B20, C10

MSC4, F30, F20

MSC5, B20, F20

MSC3, T10

MSC4, C10

MSC8, B10

B10, B20

MSC1, MSC4, MSC7,B20

MSC4, MSC1, C10, B20

MSC4, C10

MSC5, F20

T10, MSC7, C10

MSC2

T10, F20, C30

C30, MSC4

MSC3, B10

MSC2, MSC1, B10, F20

T10, C10

DC

DC

DC

AC

AC

AC

DC

DC

DC

AC

AC

AC

DC

AC

AC

AC

AC

AC

AC

DC

AC

AC

DC

AC

DC

AC

AC

AC

AC

AC

AC

AC

AC

AC

AC

AC

AC

AC

AC

AC

DC

AC

AC

AC

AC

AC

AC

AC

AC

AC

AC

AC

AC

AC

Black

White

Black

Black

Black

Black

White

White

White

Black

Black

Black

Clear

Black

Black

Black

Black

Dark

Black

Clear

Dark

Dark

Clear

Black

Clear

Black

Black

Black

Dark

Black

Black

Clear

Black

Black

Black

Black

Black

Black

Dark

Black

Black

Black

Black

Black

Black

Black

Dark

Dark

Dark

Dark

Dark

Black

Dark

MSC1

MSC1

MSC1

MSC3, MSC5

MSC3, MSC5

MSC3, MSC7

MSC3, MSC5

F30

F30

MSC7, MSC4

MSC5, MSC3

C10, MSC4

C10

MSC1,F10,C10

MSC4

MSC7

MSC7

MSC4

MSC4, 59NC

MSC4

MSC1

B10

B10

MSC1

MSC4, C10, MSC1

MSC4, C10

MSC3,F30,F20

B10,59NC,MSC3,F30

MSC1

Allow a few seconds for color to develop before cleaning

Black not possible unless lacquer filled

Deep etch BEFORE anodizing (minimum .002)

Reduce amperage if blurring occurs

Use low amperage, oil part after cleaning

Use low amperage

If coating is heavy, parts should be deep etched

Allow time for oxide to stabilize before cleaning

Blotting action improves frosted contrast

Deep etch BEFORE unless coating is very thin

Dark mark usually not stable

Use minimum amount of Electrolyte (work dry)

Use high amperage

Use low amperage, work dry, wait before cleaning

Use low amperage & minimum Electrolyte

Use low amperage & minimum Electrolyte

Use DC if AC not dark enough & minimum Electrolyte

Use DC if AC not dark enough

Allow time for oxide to stabilize before cleaning

©

COPYRIGHT 1975

ELECTROLYTES

MARKING METHODS' laboratory controlled Electrolytes are the result of years of research and development. They are carefully
formulated and cataloged by formula and batch number to mark varied metals and surface treatments.

The Electrolytes are

buffered salt solutions, pH balanced, and are completely harmless to parts and surrounding equipment when used as directed.

NUCLEAR GRADE ELECTROLYTES (non-chloride or halogen free) can be furnished that contain less then 250 ppm of chlorides (halogens), sulfur, mercury, copper, zinc, and
lead. These Electrolytes can be certified to meet MIL STD's 767 and 792 when requested.
Use a light oil film (CPO) prior to marking on sand or grit blasted surfaces to prevent blurring. Oil fills the open grain surface of the metal. This procedure is also very effective
before marking metals or plating that stain easily. Do not use gold (DF2) stencil for this application.
Submit sample parts to our laboratory for Electrolyte evaluation of particularly difficult applications.
*NOTE: POWER UNIT SETTINGS FOR ALL DEEP ETCH MARKING SHOULD BE DC AND DEEP ETCH WITH RHEOSTAT AT 3 OR HIGHER.  AMPLE  ELECTROLYTE MUST
ALWAYS BE USED. DEEP ETCHING MAY PRODUCE A FUZZY OR BLURRED MARK.  A LIGHT BUFFING AFTER CLEANING WILL SHARPEN THE LINE DEFINITION.

MARKING METHODS, INC.    ALHAMBRA,CA 91803-1531 

 626-282-8823 

 FAX 626-576-7564 

 email: [email protected] 

 VISIT OUR WEB SITE AT: www.markingmethods.com

______________________________

See

applicable

MSDS

for

safety

information.

®

Содержание MARK 300 SERIES

Страница 1: ... 576 7564 Email experts markingmethods com Website www markingmethods com MANUAL FOR ELECTRO CHEMICAL MARKING EQUIPMENT SUPPLIES ATTENTION PLEASE READ MANUAL CAREFULLY BEFORE OPERATING EQUIPMENT MARKING METHODS INC MODEL MARK 300 SERIES EQUIPMENT OPERATION ELECTROLYTE CHART SUPPLIES I N C ...

Страница 2: ...er unit is equipped with an AC DC switch The AC alternating current alternately etches out and redeposits back a combination of the metal oxide and electrolytic salts producing a black mark The DC direct current charges the applicator negatively cathodic which dissolves metal out etching a frosted or clear mark To prevent corrosion the parts must be thoroughly cleaned after marking to re move any ...

Страница 3: ...d in the Stencil with the Hand Pad for approximately 2 seconds then break contact by raising the Hand Pad from the part momentarily Continue the procedure until the desired darkness and or depth is obtained 12 To clean Stencil during marking place the Stencil on the Cleaner Tray Wick and blot over the image with the Hand Pad 13 After the desired darkness or depth is reached remove the Stencil from...

Страница 4: ...during marking as this can cause multiple marks The blotting action should be as follows 2 to 3 seconds dwell ON the part 1 second OFF the part This allows the gases to escape and affords a pulsing effect 12 After the desired depth is obtained remove the Stencil from the part and using the APC Cleaner thoroughly clean the part with a shop cloth by using a hard rubbing action making sure that none ...

Страница 5: ...round Finger Ground or with the alligator clip NOTE Etching may be accomplished by rolling the part across the stencil with Hand Ground or by placing the part in the Locating Plate and grounding with the Hand Ground or Finger Ground 12 After marking each part thoroughly clean the parts with APC Cleaner by wetting a clean shop cloth with the Cleaner and rubbing the part making sure that none of the...

Страница 6: ... MSC4 MSC5 MSC3 C10 MSC4 C10 MSC1 F10 C10 MSC4 MSC7 MSC7 MSC4 MSC4 59NC MSC4 MSC1 B10 B10 MSC1 MSC4 C10 MSC1 MSC4 C10 MSC3 F30 F20 B10 59NC MSC3 F30 MSC1 Allow a few seconds for color to develop before cleaning Black not possible unless lacquer filled Deep etch BEFORE anodizing minimum 002 Reduce amperage if blurring occurs Use low amperage oil part after cleaning Use low amperage If coating is he...

Страница 7: ...ch x 7 inch Heavy duty opaque BLUE 3 3 4 inch x 7 inch Heavy duty opaque BLUE 2 1 2 inch x 7 inch Heavy duty opaque GREEN BENCH FIXTURE WICK PAD 1 1 2 x 2 Pkg of 10 BENCH FIXTURE WICK PAD 2 x 4 1 2 Pkg of 10 BENCH FIXTURE WICK PAD 4 x 6 Pkg of 10 STENCIL CLEANER TRAY STENCIL CLEANER TRAY WICK PADS Pkg of 10 1 4 x 3 4 1 2 x 1 1 2 1 x 2 WICKS WICKS WICKS Pkg of 10 Pkg of 10 DEEP ETCH WICKS HPW 1 x 2...

Страница 8: ...ng desired depth and before moving stencil switch DC to AC and DEEP ETCH to NORMAL ETCH Then blot several more times Replace cord set Disconnect unit from wall socket immediately and call manufacturer Set the typewriter on stencil position or remove the ribbon Type on the colored side of the stencil then remove the backing to mark W ARRAN TY The MARK 300 POWER UNIT is warranted to be free from def...

Отзывы:

Похожие инструкции для MARK 300 SERIES