background image

I N C

MARKING METHODS, INC.

ELECTRO-CHEMICAL, LASER MARKING SPECIALISTS,

ALHAMBRA, CALIFORNIA

MARK   300

MODEL

AMPERES

AC.

5

10

15

20

25

0

1

2

3

4

5

MARK

GROUND

CLEANER

P

US

H TO

R ESET

OFF

DC

DEEP
ETCH

NORMAL

ETCH

AC

ON

(1) Plug the line cord connected to the back of the Power Unit into a 110/120
     VAC outlet only.  Converters are available on request for 220/240 VAC.
(2) Plug the BLACK cord into the BLACK (MARK) receptacle: the opposite
     end of the cord into the Bench Fixture.
(3) Plug the RED Cord into the RED (GROUND) receptacle; slide the alligator
     clip off the opposite end and slide on the Hand Ground.
(4) Set the AC-DC Switch on AC for most metals and DC for Aluminum and Black

Oxide.  AC produces a black mark;  DC produces a frosted or clear mark.

(5)  Set the Normal/Deep-Etch Switch on NORMAL.

    (6) Set the Rheostat on No.5.   Note: If the mark is blurred, turn the
        Rheostat to a lower position.
  (7) Place a clean Wick Pad on the graphite block in the Bench Fixture

(green side down) and secure the Wick with a Retainer Ring.

  (8) Saturate the Wick Pad with the proper Electrolyte.  Select the
        proper Electrolyte from the chart on page 5.
  (9) Place Stencil with the legend reading REVERSED over Wick Pad

and secure a second Retainer Ring. (Stencil may also be secured

        by a Locating Plate, which is milled to fit the part).*
(10)  Set the ON-OFF Switch to ON position.
(11) Place part to be marked in fixture and ground by touching part

with either the Hand Ground, Finger Ground, or with the alligator 
clip.   NOTE:  Etching may be accomplished by rolling the part
across the stencil with Hand Ground or by placing the part in the 
Locating Plate and grounding with the Hand Ground or Finger

        Ground.
(12) After marking each part, thoroughly clean the  parts with APC 

Cleaner by wetting a clean shop cloth with the Cleaner and

        rubbing the part, making sure that none of the Electrolyte is  left 

on the part, or by immersing the part in a small open container 

        filled with APC Cleaner.
(13) After cleaning the parts thoroughly, dry them with a clean dry cloth.
(14) After marking is completed, turn the ON-OFF switch to OFF.
        Unplug the BLACK and RED cords from their receptacles.
(15) Remove the Wick Pad from the graphite block and wash

 thoroughly with water.  Wick Pads are reusable if they wash out

        reasonably clean.

(16) With water, thoroughly rinse the Bench Fixture, Retainer Rings, Hand Ground and any other material that came in
       contact with the Electrolyte.
(17) Dry the above mentioned items with a clean, dry cloth.
(18) Discard all used Electrolyte and Cleaner.   NOTE:  Never pour used Electrolyte and Cleaner back into the bottles as
       the oxidation from the parts will contaminate the fresh solutions.
(19) After all these steps have been followed, your equipment and supplies will be ready for use the next time.

BENCH FIXTURES

INSTRUCTIONS for using BF1520, BF2045 & BF4060 BENCH FIXTURES 

with MARK 300 POWER UNIT

(NORMAL ETCH ONLY)

LOCATING
PLATE

WING NUT

RETAINER RING

STENCIL

WICK PAD

SPACER

MARKING
BLOCK

BENCH
FIXTURE
BASE

RECEPTACLE
BOLT

SCREWS

* See  back cover for Die-Impression Stencil instructions. 

-4-

Содержание MARK 300 SERIES

Страница 1: ... 576 7564 Email experts markingmethods com Website www markingmethods com MANUAL FOR ELECTRO CHEMICAL MARKING EQUIPMENT SUPPLIES ATTENTION PLEASE READ MANUAL CAREFULLY BEFORE OPERATING EQUIPMENT MARKING METHODS INC MODEL MARK 300 SERIES EQUIPMENT OPERATION ELECTROLYTE CHART SUPPLIES I N C ...

Страница 2: ...er unit is equipped with an AC DC switch The AC alternating current alternately etches out and redeposits back a combination of the metal oxide and electrolytic salts producing a black mark The DC direct current charges the applicator negatively cathodic which dissolves metal out etching a frosted or clear mark To prevent corrosion the parts must be thoroughly cleaned after marking to re move any ...

Страница 3: ...d in the Stencil with the Hand Pad for approximately 2 seconds then break contact by raising the Hand Pad from the part momentarily Continue the procedure until the desired darkness and or depth is obtained 12 To clean Stencil during marking place the Stencil on the Cleaner Tray Wick and blot over the image with the Hand Pad 13 After the desired darkness or depth is reached remove the Stencil from...

Страница 4: ...during marking as this can cause multiple marks The blotting action should be as follows 2 to 3 seconds dwell ON the part 1 second OFF the part This allows the gases to escape and affords a pulsing effect 12 After the desired depth is obtained remove the Stencil from the part and using the APC Cleaner thoroughly clean the part with a shop cloth by using a hard rubbing action making sure that none ...

Страница 5: ...round Finger Ground or with the alligator clip NOTE Etching may be accomplished by rolling the part across the stencil with Hand Ground or by placing the part in the Locating Plate and grounding with the Hand Ground or Finger Ground 12 After marking each part thoroughly clean the parts with APC Cleaner by wetting a clean shop cloth with the Cleaner and rubbing the part making sure that none of the...

Страница 6: ... MSC4 MSC5 MSC3 C10 MSC4 C10 MSC1 F10 C10 MSC4 MSC7 MSC7 MSC4 MSC4 59NC MSC4 MSC1 B10 B10 MSC1 MSC4 C10 MSC1 MSC4 C10 MSC3 F30 F20 B10 59NC MSC3 F30 MSC1 Allow a few seconds for color to develop before cleaning Black not possible unless lacquer filled Deep etch BEFORE anodizing minimum 002 Reduce amperage if blurring occurs Use low amperage oil part after cleaning Use low amperage If coating is he...

Страница 7: ...ch x 7 inch Heavy duty opaque BLUE 3 3 4 inch x 7 inch Heavy duty opaque BLUE 2 1 2 inch x 7 inch Heavy duty opaque GREEN BENCH FIXTURE WICK PAD 1 1 2 x 2 Pkg of 10 BENCH FIXTURE WICK PAD 2 x 4 1 2 Pkg of 10 BENCH FIXTURE WICK PAD 4 x 6 Pkg of 10 STENCIL CLEANER TRAY STENCIL CLEANER TRAY WICK PADS Pkg of 10 1 4 x 3 4 1 2 x 1 1 2 1 x 2 WICKS WICKS WICKS Pkg of 10 Pkg of 10 DEEP ETCH WICKS HPW 1 x 2...

Страница 8: ...ng desired depth and before moving stencil switch DC to AC and DEEP ETCH to NORMAL ETCH Then blot several more times Replace cord set Disconnect unit from wall socket immediately and call manufacturer Set the typewriter on stencil position or remove the ribbon Type on the colored side of the stencil then remove the backing to mark W ARRAN TY The MARK 300 POWER UNIT is warranted to be free from def...

Отзывы:

Похожие инструкции для MARK 300 SERIES