Markilux 779 Скачать руководство пользователя страница 14

14

9  Disassembly and disposal

9.1  Dismantling

9.2  Disposal

Packaging

Batteries

Electrical units

The awning must be removed only by a markilux specialist company.

The packaging protects the product from transport damage. The packaging materials are selected according to 
environmental and disposal aspects and are therefore recyclable.

Returning the packing to the materials circuit saves raw materials and reduces the accumulation of waste. 

It is therefore essential that you dispose of packaging materials that are no longer required in accordance with the 
applicable legal regulations.

Electrical units are not worthless waste. Valuable raw materials can be recovered through environmentally friendly 
disposal. 

This product is marked in accordance with Directive 2012/19/EU on Waste Electrical and Electronic Equipment 
(WEEE)

At the end of its service life, this product must not be disposed of with normal household waste, but must be taken 
to a collection point for the recycling of electrical and electronic equipment. The symbol on the product, the 
instructions for use or the packaging indicates this. 

By reusing, recycling or other forms of recycling electrical units, you make an important contribution to the 
protection of our environment.

It is therefore essential that you dispose of electrical units in accordance with the applicable legal regulations.

Batteries and battery packs can contain toxins that are harmful to the environment. Batteries and battery packs 
must not be disposed of in normal household waste 

It is therefore essential that you dispose of batteries and battery packs in accordance with the applicable legal 
regulations. 

markilux 779 tracfix / 879 tracfix

markilux.com

Operation manual

Содержание 779

Страница 1: ... during extension 3 tracfix cover guide without gap to the guide track 1 front profile finishes flush with the ends of the guide tracks 4 5 LED Line fitted to the guide track and cover support tube 1 LED line to guide rail and LET spotlights on cover support tube 1 LED line to guide rail 1 cover support stainless steel wire 8 6 7 1 Optional configuration Operation manual ...

Страница 2: ...Reading the instructions 7 2 Awning with manual operation 7 3 Awning with motorised operation 8 4 Awning with shadeplus 8 5 Modification or retrofitting 9 6 Awning with lighting optional 10 7 Replacement of a faulty illuminant for lighting 12 7 1 Overview spare parts lighting LED Spots 12 7 2 LED line 12 8 Maintenance and care 13 8 1 Cleaning the guide tracks 13 8 2 Risk of injury from defective c...

Страница 3: ...ing is not extended entirely then it must not be burdened by rainwater If this is the case there is a risk of the formation of water troughs in the awning cover and the awning may become damaged or even detached from the wall Alterations like rebuilding or enlargements which are not intended by the manufacturer may only be carried out with the markilux manufacturers written approval Additional awn...

Страница 4: ...ation behind the awning must be avoided by installing a snow guard snow fence or similar or by regularly removing the snow load In the awning extension area no obstacles may be located There is danger for persons to be squashed in there In order to avoid this a safety distance of at least 50 cm has to be observed A motor driven awning cannot be retracted without electricity In very windy areas wit...

Страница 5: ...such installations 13 Metallic and pearl glimmer coatings of the awning frame The look of plastic coatings of metal and plastic parts in metallic and or pearl glimmer colour vary These visual differences concern in particular the intensity and characteristic of the metallic effect which may also lead to a change in the perception of the basic shade 14 Disassembly and disposal Attention Risk of inj...

Страница 6: ...d uncoiling of the cover on the roller This effect can be explained by the fact that the material is thicker close to the seams coils more loosely between the seams of the cover This effect can occur both directly next to the seam as well as also in the middle of web Other irregularities Irregularities caused by the production process which cannot be avoided such as Knots thread thickening and thi...

Страница 7: ...the opposite If the crank rod should remain in the gear eyelet it must be secured against uncontrolled movement e g in case of wind Awnings with manual operation have a transmission end stop to limit the extension path It prevents incorrect coiling of the cover onto the roller tube The transmission end stop must never be approached with force Shortly before reaching the end position in the extendi...

Страница 8: ...by pressing the buttons button for extension retraction With radio controlled operation your markilux specialist must exactly explain the functions on the radio remote control to you since depending on the equipment he can set these for you individually Observe here the separate operating instructions of the motor and if available of the controller manufacturer The end stop for extension retractio...

Страница 9: ...s of rotation are exactly the opposite When retracting and extending the awning the crank rod must be removed from the gear eye as otherwise the cover support tube and the front profile of the awning suffer damage Remove the crank rod from the gear eye after retraction or extension and store the crank rod in a safe place If the crank rod should remain in the gear eyelet it must be secured against ...

Страница 10: ...lighting in the guide rails without cover support tube 10 LED Line in the guide rails 11 LED Line in cover support tube 12 LED Spots in the cover support tube Pivotable LED spotlights in the cover support tube and or the cover cassette LED line laterally on the guide tracks and or in the cover support tube and or in the cover cassette 11 10 12 12 11 10 12 9 13 9 13 LED line laterally on the guide ...

Страница 11: ...e ensured whether the electrician has protected the connection of your lighting via an RCCB 30mA so that any eventual cable breakage does not pose any hazard For safety reasons the electronic transformer switches off automatically at a temperature of 80 C and on again after an appropriate cooling down phase Automatic switchoff Thanks to the integrated timer the spotlights switch off automatically ...

Страница 12: ... cable connections have been established completely chapter Lighting type Article no 7 2 1 piece LED spotlight with plug in the front profile 714881 1 2 3 4 714881 1 2 3 1 Loosen the hexagon nut 2 with a SW 13 spanner Afterwards turn the defective LED spotlight 1 by 90 to the left to bring the pincher carriage 3 direction of the groove and pull it out 2 Disconnect the plug 4 of the defective spot ...

Страница 13: ...revent noises When the front profile is inclined during the extension phase of the awning there is the risk of falling components Stop the awning immediately and contact your specialist partner The awning must no longer be operated If the awning has a motor drive the power supply must be interrupted A tensioning belt included in the awning is possibly defective and causes possible major damage The...

Страница 14: ...Directive 2012 19 EU on Waste Electrical and Electronic Equipment WEEE At the end of its service life this product must not be disposed of with normal household waste but must be taken to a collection point for the recycling of electrical and electronic equipment The symbol on the product the instructions for use or the packaging indicates this By reusing recycling or other forms of recycling elec...

Отзывы: