Markilux 710 Скачать руководство пользователя страница 4

Dimensions and configuration options

32

markilux 710 / 810

Operation

manual operation; handle with bayonet fitting

manual operation from inside the building

manual operation from the rear

hard-wired motor

radio-controlled motor

○*

Covers

sunsilk snc (fabric series 324xx/329xx)

1

sunsilk snc signature (fabric series 369xx)

1

acrylic 34 (fabric series 341xx-347xx)

2

widely woven acrylic (fabric series 349xx)

3

sunsilk perla FR (fabric series 374xx/379xx)

4

perfotex (fabric series 333xx)

2

transolair (fabric series 339xx)

5

Soltis 92

6

Miscellaneous

light and wind sensor

cover profiles for gap between tracks and cover

wedge-in accro bars

markilux PVC windows

Coupled units

coupled unit, 2 fields

coupled unit, 3 fields

● = standard specification

○ = optional accessories

– = not available

○* = radio-controlled motor using 433 MHz technology

1

= in the case of the markilux 710 the maximum unit height is 300 cm

2

= in the case of the markilux 710 the maximum unit height is 250 cm

3

= from an overall width of 329 cm and a unit height of 316 cm with 

horizontal seam

4

= in the case of the markilux 710 the maximum unit height is 250 cm

5

= cover seamless, from an awning width of 261 cm and a unit height of 248 

cm with horizontal seam.

6

= cover seamless, from an awning width of 186 cm and a unit height of 173 

cm with horizontal seam

Frame colours

traffic white - RAL 9016

white aluminium - RAL 9006

grey brown - similar to RAL 8019

non-standard powder-coated finish

The  width  of  the  awning  cover  is  always 

less

  than  the  width  of  the  awning. 

Coupled units on request.

Standard  manual  operation  with  bayonet  fitting  and  universal  joint  made  of 

stainless steel is operated from outside the building (winding handle lengths 110, 

140, 160, 180 or 220 cm).
Manual interior operation with universal joint:

 this operation type requires exact 

fixture, usually means high (labour) costs for the end consumer and can only be 

employed on single units. We therefore recommend the use of a radio-controlled 

motor. 

Manual operation using 

a universal joint 

and from the rear: 

This operation type 

should be used in installations when the system can be approached from the rear 

(e.g. on balconies).
In  the  case  of  manual  operation  it  takes  approximately  24  turns  per  metre  of 

overall unit height to extend the system.

Extension when using a motor

 takes approximately 15 seconds per metre.

N.B.!

 

If  the  motor  is  used  continuously 

it  will  stop  automatically  after  3  to  4 

minutes 

to prevent overheating.

In the case of a bank of awnings operating simultaneously,

 the same speed of 

rotation  of  the  motors  cannot  be  guaranteed  because  of  tolerances  within  the 

motors themselves.

If 

a number of single blinds

 are to be installed 

next to one another

 there must be 

a distance of at least 25 mm between the blinds in the case of the markilux 710 

and 30 mm in the case of the markilux 810.
If coupled blinds are fitted into a 

recess

 or 

reveal

 the overall width of the coupled 

awning must be at least 6 cm less than the width of the opening to allow the 

awning to be coupled. Make a special note if an awning is to be fitted into a recess 

or reveal and note the recess/reveal dimensions separately on the order.
Coupled units are only available with motor (surcharge)
Maximum width of coupled units: 2 x 500 cm

= available, 3 brackets per cassette

= available, 2 brackets per cassette

blind width

minimum 

width

unit 

height

75

100 125 150 175 200 225 250 275 300 325 350 375 400 425 450 475 500

hard-wired

motor

radio-

controlled

motor

71-75 76-100 101-125 126-150 151-175 176-200 201-225 226-250 251-275 276-300 301-325 326-350 351-375 376-400 401-425 426-450 451-475 476-500

120

75

74

160
200
250
300
350

dimensions in cm

Colours similar to the RAL chart - these may differ slightly from those depicted in 

both hue and finish.

Housing tolerances / Awning cover dimensions

Width

unit 

height

housing tolerance

+5 / -10 

awning cover width = width less 

80

blind/awning cover length = unit height

±0

dimensions in mm

Содержание 710

Страница 1: ... markilux 893 markilux 745 845 markilux 740 840 markilux 791 891 markilux 730 830 markilux 760 860 markilux 750 850 markilux 725 825 markilux 720 820 markilux 710 810 Specification markilux Collection The Vertical cassette blinds with lateral guide cables proven and practical classic and classy markilux 710 810 ...

Страница 2: ... and universal joint extremely sturdy stainless steel side cheek sheathed in plastic and powder coated also available as a coupled unit to span large widths vertical blind complete protection from the sun and inquisitive glances markilux 710 compact square and discreet the cassette profile made of extruded aluminium is only 95 mm in height for long lasting attractiveness the awning has been powder...

Страница 3: ...0 810 Specification markilux Collection manual operation from inside the building manual operation from the rear hard wired or radio controlled motor with remote control light and wind sensor coupled units non standard powder coated finish markilux 710 810 manual operation handle with bayonet fitting bonded awning cover sunsilk snc fabric sunsilk snc signature fabric acrylic fabric 34 widely woven...

Страница 4: ... can only be employed on single units We therefore recommend the use of a radio controlled motor Manual operation using a universal joint and from the rear This operation type should be used in installations when the system can be approached from the rear e g on balconies In the case of manual operation it takes approximately 24 turns per metre of overall unit height to extend the system Extension...

Страница 5: ...Face fixture bracket assembly with fishplate for lateral fixture right N B Not for the operation side interior operation operation from the rear 50 mm 50 mm 78726 78727 78748 Face fixture bracket assembly with fishplate for lateral fixture left N B Not for the operation side interior operation operation from the rear Face fixture bracket assembly for central fixture coupled unit 78749 78745 markil...

Страница 6: ...markilux 710 810 markilux 710 810 Spreader plate assembly for face universal bracket Accessory pack for 2 guide cables Accessory pack for a coupled cable clamp 100 x 120 x 10 mm 78982 78761 78910 Reducing bolt assembly M 10 M 6 SW 13 30 mm length please refer to the section Technical Information 753211 ...

Страница 7: ... 710 810 Dimension overview Face fixture Top and reveal fixture AH unit height H drop M overall blind awning width HT bracket AU exterior IN interior TB cover width MF centre of the cable guide centre of the stainless steel guide rod fixture width 95 50 min 50 max 200 32 10 105 135 7 42 min 135 3 27 9 3 107 9 95 45 35 6 95 98 95 10 105 50 9 3 max 200 32 107 50 29 27 45 35 95 9 6 20 15 15 6 42 98 3...

Страница 8: ...er width MF centre of the cable guide centre of the stainless steel guide rod fixture width M MF AH 105 6 111 50 50 40 40 TB 100 15 55 8 60 40 15 10 30 6 50 48 NB 30 30 22 22 HT Reveal fixture for gearbox motor 6 73 85 6 5 22 m in 1 2 4 35 42 32 3 95 98 128 31 1 7 12 95 105 max 450 10 BD Face fixture with interior operation How to install the markilux 710 ...

Страница 9: ...arkilux 750 850 markilux 725 825 markilux 720 820 markilux 710 810 Specification markilux Collection markilux 710 810 SK chase out depth 85 6 4 1 73 5 5 90 33 12 22 ca 500 14 32 5 5 4 6 6 2 6 4 16 31 4 SK M5 12 28 41 6 Winding handle for interior operation Ø 16 mm up to a vertical angle of 90 and a horizontal angle of 5 47 47 14 Cable exit point in the case of motor driven units How to install the...

Страница 10: ...38 dimensions in mm markilux 710 810 33 22 24 32 96 105 8 6 3 50 9 32 9 96 105 35 45 27 Operation from the rear How to install the markilux 710 ...

Страница 11: ...0 810 Face fixture Dimension overview Top and reveal fixture AH unit height H drop M overall blind awning width HT bracket AU exterior IN interior TB cover width MF centre of the cable guide centre of the stainless steel guide rod fixture width 84 20 42 min 155 8 123 115 50 30 min 50 max 200 8 34 40 8 115 135 115 167 20 95 50 50 2 125 min 50 max 200 33 35 27 32 9 9 6 6 115 8 15 15 20 115 117 10 11...

Страница 12: ...eal width BD horizontal drill hole TB cover width MF centre of the cable guide centre of the stainless steel guide rod fixture width HT Reveal fixture for gearbox motor m in 12 4 max 450 125 28 2 41 24 12 22 6 73 36 42 85 6 5 10 115 149 117 115 BD Face fixture with interior operation How to install the markilux 810 ...

Страница 13: ...arkilux 750 850 markilux 725 825 markilux 720 820 markilux 710 810 Specification markilux Collection markilux 710 810 SK chase out depth 85 6 4 1 73 5 5 90 33 12 22 ca 500 14 32 5 5 4 6 6 2 6 4 16 31 4 SK M5 12 28 41 6 Winding handle for interior operation Ø 16 mm up to a vertical angle of 90 and a horizontal angle of 5 23 103 13 Cable exit point in the case of motor driven units How to install th...

Страница 14: ...42 dimensions in mm markilux 710 810 MB bracket fixture range 50 84 9 136 168 117 19 115 41 20 30 34 min 52 29 Operation from the rear How to install the markilux 810 ...