Markilux 710 Скачать руководство пользователя страница 2

30

Additional features

Technical highlights

Design features

markilux 710 / 810

• hard-wired motor operation 

(optionally with automatic 

weather controls) for 

straightforward and 

easy operation

• radio-controlled motor 

with radio remote control 

for ease of use

• an easily installed, radio 

control light and wind 

sensor guarantees comfort 

and a degree of safety - 

even in your absence

• handle for interior operation, 

for manual operation 

from inside the room

• the cover is guided down 

plastic-coated cables

• robust, self-supporting cassette 

made of extruded aluminium

• operation by means of a smooth 

gearbox and universal joint

• extremely sturdy, stainless 

steel side cheek sheathed in 

plastic and powder coated

• also available as a coupled 

unit to span large widths

• vertical blind, complete 

protection from the sun 

and inquisitive glances 

• markilux 710: compact, square 

and discreet, the cassette profi le 

made of extruded aluminium 

is only 95 mm in height

• for long-lasting attractiveness 

the awning has been 

powder coated

• when retracted the cover is 

protected from the weather 

by the cassette, which 

encloses it completely

• one-piece covers made from 

widely woven, plain awning 

fabrics make it possible to do 

away with seams entirely 

The vertical cassette blinds with lateral guide cables, proven and 

practical, classic and classy

markilux 

710 / 810

rated to wind resistance class 2

(corresponds to Beaufort 5)

Содержание 710

Страница 1: ... markilux 893 markilux 745 845 markilux 740 840 markilux 791 891 markilux 730 830 markilux 760 860 markilux 750 850 markilux 725 825 markilux 720 820 markilux 710 810 Specification markilux Collection The Vertical cassette blinds with lateral guide cables proven and practical classic and classy markilux 710 810 ...

Страница 2: ... and universal joint extremely sturdy stainless steel side cheek sheathed in plastic and powder coated also available as a coupled unit to span large widths vertical blind complete protection from the sun and inquisitive glances markilux 710 compact square and discreet the cassette profile made of extruded aluminium is only 95 mm in height for long lasting attractiveness the awning has been powder...

Страница 3: ...0 810 Specification markilux Collection manual operation from inside the building manual operation from the rear hard wired or radio controlled motor with remote control light and wind sensor coupled units non standard powder coated finish markilux 710 810 manual operation handle with bayonet fitting bonded awning cover sunsilk snc fabric sunsilk snc signature fabric acrylic fabric 34 widely woven...

Страница 4: ... can only be employed on single units We therefore recommend the use of a radio controlled motor Manual operation using a universal joint and from the rear This operation type should be used in installations when the system can be approached from the rear e g on balconies In the case of manual operation it takes approximately 24 turns per metre of overall unit height to extend the system Extension...

Страница 5: ...Face fixture bracket assembly with fishplate for lateral fixture right N B Not for the operation side interior operation operation from the rear 50 mm 50 mm 78726 78727 78748 Face fixture bracket assembly with fishplate for lateral fixture left N B Not for the operation side interior operation operation from the rear Face fixture bracket assembly for central fixture coupled unit 78749 78745 markil...

Страница 6: ...markilux 710 810 markilux 710 810 Spreader plate assembly for face universal bracket Accessory pack for 2 guide cables Accessory pack for a coupled cable clamp 100 x 120 x 10 mm 78982 78761 78910 Reducing bolt assembly M 10 M 6 SW 13 30 mm length please refer to the section Technical Information 753211 ...

Страница 7: ... 710 810 Dimension overview Face fixture Top and reveal fixture AH unit height H drop M overall blind awning width HT bracket AU exterior IN interior TB cover width MF centre of the cable guide centre of the stainless steel guide rod fixture width 95 50 min 50 max 200 32 10 105 135 7 42 min 135 3 27 9 3 107 9 95 45 35 6 95 98 95 10 105 50 9 3 max 200 32 107 50 29 27 45 35 95 9 6 20 15 15 6 42 98 3...

Страница 8: ...er width MF centre of the cable guide centre of the stainless steel guide rod fixture width M MF AH 105 6 111 50 50 40 40 TB 100 15 55 8 60 40 15 10 30 6 50 48 NB 30 30 22 22 HT Reveal fixture for gearbox motor 6 73 85 6 5 22 m in 1 2 4 35 42 32 3 95 98 128 31 1 7 12 95 105 max 450 10 BD Face fixture with interior operation How to install the markilux 710 ...

Страница 9: ...arkilux 750 850 markilux 725 825 markilux 720 820 markilux 710 810 Specification markilux Collection markilux 710 810 SK chase out depth 85 6 4 1 73 5 5 90 33 12 22 ca 500 14 32 5 5 4 6 6 2 6 4 16 31 4 SK M5 12 28 41 6 Winding handle for interior operation Ø 16 mm up to a vertical angle of 90 and a horizontal angle of 5 47 47 14 Cable exit point in the case of motor driven units How to install the...

Страница 10: ...38 dimensions in mm markilux 710 810 33 22 24 32 96 105 8 6 3 50 9 32 9 96 105 35 45 27 Operation from the rear How to install the markilux 710 ...

Страница 11: ...0 810 Face fixture Dimension overview Top and reveal fixture AH unit height H drop M overall blind awning width HT bracket AU exterior IN interior TB cover width MF centre of the cable guide centre of the stainless steel guide rod fixture width 84 20 42 min 155 8 123 115 50 30 min 50 max 200 8 34 40 8 115 135 115 167 20 95 50 50 2 125 min 50 max 200 33 35 27 32 9 9 6 6 115 8 15 15 20 115 117 10 11...

Страница 12: ...eal width BD horizontal drill hole TB cover width MF centre of the cable guide centre of the stainless steel guide rod fixture width HT Reveal fixture for gearbox motor m in 12 4 max 450 125 28 2 41 24 12 22 6 73 36 42 85 6 5 10 115 149 117 115 BD Face fixture with interior operation How to install the markilux 810 ...

Страница 13: ...arkilux 750 850 markilux 725 825 markilux 720 820 markilux 710 810 Specification markilux Collection markilux 710 810 SK chase out depth 85 6 4 1 73 5 5 90 33 12 22 ca 500 14 32 5 5 4 6 6 2 6 4 16 31 4 SK M5 12 28 41 6 Winding handle for interior operation Ø 16 mm up to a vertical angle of 90 and a horizontal angle of 5 23 103 13 Cable exit point in the case of motor driven units How to install th...

Страница 14: ...42 dimensions in mm markilux 710 810 MB bracket fixture range 50 84 9 136 168 117 19 115 41 20 30 34 min 52 29 Operation from the rear How to install the markilux 810 ...

Отзывы: