8.3 Lighting with On/Off switch
(6)=Not used!
8.3.1
The cable for the lighting connection is
marked with this sticker.
The wiring diagram must definitely be observed, a
faulty connection can lead to the destruction of the
device!
Wire color
Terminal
(1) gray
Not used!
(2) black
Not used!
(3) brown
230 V~ voltage supply phase
(4) blue
230 V~ voltage supply neutral
conductor
(5)
green/yellow
230 V~ voltage supply protective
conductor
8.3.2
For the connection of the supply and control
cable, 5 approved screw terminals or non-screwed
terminals with a rated voltage of at least 230 V~
are required.
Attention Danger to Life:
Electrical operation
without protective conductor connection is not
permitted! It is to be observed, that during operation
the protective conductor (5) green/yellow is neither
interrupted in/on the product nor by the mains cable.
All electrical connections and connection leads must
definitely be checked after being connected and
before the first trial operation!
8.3.3
Technical data of a lamp:
Power supply:
230 VAC 50 Hz
(10/16A)
Max. wattage:
39 W
Lamp:
OSRAM FQ39W/827
System of protection:
IP 54
Supply cable cross-section: min. 1.0 mm²
9. Awning with Shadeplus and Motor Drive
with radio (433 MHz):
U = 230 V ~ / 100 W, 50 Hz, I = 0,80 A
The electrical connection for motor drive Shadeplus
is to be carried out as prescribed by the motor and
controller manufacturer. Modifications, in particular
concerning the motor, the controller and the
connection lead require written authorization.
The installation and setting guide for the motor is
enclosed with the fitting instructions.
The integrated motor has learnt end positions. This
setting is carried out at works. If it needs to be
altered or corrected, one must proceed according to
the motor guide (with radio: portable transmitter)
without radio:
U = 230 V ~ / 80 W, 50 Hz, I = 0,40 A