A. IF GAS PRESSURE IS LOW:
Check your gas supply line for a restriction. If no restriction exists, check with your Natural
gas supplier to provide at least 5” of water column pressure in the gas supply line. If no
restriction exists and Propane gas is being used, the tank pressure regulator should be ad
-
justed to supply at least 11” of water column pressure in the gas supply line. If this adjust
-
ment cannot be made to your satisfaction, the gas supplier should be notified.
B. IF GAS PRESSURE IS TOO HIGH:
Adjust the pressure regulator on the boiler gas valve to reduce the pressure if Natural gas
is being used. If Propane gas is being used, adjust the pressure regulator supplied by the
gas supplier. If the regulator cannot be adjusted, notify the gas supplier.
ADJUSTMENTS
____________________________________________________________________________