5

INSTALLATION

Kettle Installation & Utility Connection

WATER CONNECTION

On units equipped with an optional water fill valve connect 

a water line (minimum 1/4”) to the valve with a 1/4” NPT 

female fitting.  Units with dual (hot and cold) valves must 

have the hot water line connected to side with the hot wa-

ter valve (red) and cold water line to the cold water valve 

(blue).  Plastic or rubber hose is not recommended, as it 

may melt against the hot kettle side.

ELECTRICAL CONNECTION

   WARNING

Do not connect the kettle to the electrical sup-

ply until after the gas connection has been 

made.

1.  120 VAC - 60 Hz - Single Phase

   WARNING

ELECTRICAL GROUNDING INSTRUCTIONS
This appliance is equipped with a three-prong 

(grounding) plug for your protection against 

shock hazard and should be plugged directly 

into a properly grounded three-prong recep-

tacle.  Do not cut or remove the grounding 

prong from this plug.  (120V units only).

Units with this electrical rating are factory supplied with a 

three-wired cord and three-prong plug which fits any stan-

dard 120V, three-prong grounded receptacle.  A separate 

15 amp supply is needed for each unit.

2.  208/240 VAC - 60 Hz - Single and Three Phase
Units with this electrical rating are factory equipped with 

a transformer. To connect supply wires, remove cover 

from right console.  Route supply wires and ground wire 

through  the  hole  in  the  console  with  a  strain  relief  fit-

ting.  Connect wires to the terminal block in the rear of 

the right console. Connect ground wire to lug. Replace 

cover.  Three-phase units are wired as above, using only 

two supply wires.  The third supply wire is not connected 

and must be properly terminated.

3.  220 VAC - 50 Hz - Single Phase
Units equipped with this voltage ratings should be wired 

exactly as in (2.) above.

PERFORMANCE CHECK

The following items should be checked before or within 

the first 30 days of operation by a qualified service techni-

cian.
1.  Verify correct gas type against rating plate on unit.
2.  Verify correct voltage, cycle and phase against rating 

plate on unit.

3.  Gas pressure.
4.  Internal gas connections.
5.  Internal electrical connections.
6.  Burners - adjustment and ignition.
7.  Thermostat - cycle for operation check.  
8.  Gas supply valve - check for operation.
9.  Check hinge and lid assembly.
10. Draw-off valve - check operation.
11.  Advise user on cleaning procedure.  

Содержание FT-40GLS

Страница 1: ...FT 40GLS SHORT HEIGHT GAS TILTING KETTLE INSTALLATION OPERATION MAINTENANCE Telephone 802 658 6600 Fax 802 864 0183 www marketforge com PN 14 0573 Rev A 4 15 2015 Market Forge ...

Страница 2: ...Your Service Agency s Address Model Serial number Kettle installed by Installation checked by ...

Страница 3: ... before in stalling or servicing this equip ment INSTRUCTIONS TO BE FOL LOWED IN THE EVENT THE USER SMELLS GAS MUST BE POSTED IN A PROMINENT LO CATION This information may be obtained by contacting your local gas supplier FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance Do not obstruct the flow of com bustion and venti...

Страница 4: ...STALLATION CLEARANCE Left Side Right Side Rear 0 0mm 0 0mm 4 102mm BTU Hour 125 000 kW Hour 36 63 Gas Supply Supply Pipe Pressure W C Natural 6 14 152 356mm Propane 11 14 279 356mm Use on non combustible floors only Shown with option faucet cover and draw off Ø7 16 11mm HOLES 2 EQUALLY SPACED ON 2 5 63mm B C REAR FLANGED FOOT DETAIL 6 38 162 36 914 WATER LEVEL PRESSURE COOK TEMP LOW WATER COOKING ...

Страница 5: ...led at an angle of 45 degrees or more with the horizontal This position prevents drip ping of grease and facilitates collecting the run off grease in a drip pan usually installed with the filter A strong ex haust fan tends to create a vacuum in the room and may interfere with burner performance or may extinguish pilot flames Makeup air openings approximately equal to the fan area will relieve such...

Страница 6: ...other gas type A 3 4 NPT line is provided at the rear for the connection Each unit is equipped with an internal pressure regulator which is set for 3 5 W C manifold pressure for natural gas and 4 0 W C for propane gas Use 1 8 pipe tap on the downstream side of the combination valve for check ing pressure An adequate gas supply is imperative Undersized or low pressure lines will restrict the volume...

Страница 7: ...ounded receptacle A separate 15 amp supply is needed for each unit 2 208 240 VAC 60 Hz Single and Three Phase Units with this electrical rating are factory equipped with a transformer To connect supply wires remove cover from right console Route supply wires and ground wire through the hole in the console with a strain relief fit ting Connect wires to the terminal block in the rear of the right co...

Страница 8: ...ght posi tion turn power switch ON 3 Set thermostat to maximum initiating a 30 second pre purge Red COOKING pilot will come on and after 30 seconds the green IGNITION pilot will come on lighting the main burners If after 36 seconds the burner fails to ignite or the ignition light goes out the system goes into Safety Lockout De energize the system by setting the ther mostat to OFF for five minutes ...

Страница 9: ...at must be set at a desired setting in order for the burner to ignite For Reference DIAL SETTING C F 1 15 60 2 27 81 3 40 104 4 53 127 5 67 153 6 81 178 7 95 203 8 108 226 9 122 252 10 135 275 PRESSURE GAUGE The pressure gauge indicates the internal operating pres sure of the kettle When cold the gauge should point to the green vacuum zone If it does not refer to Re estab lishing Vacuum section Un...

Страница 10: ...o prevent pitting Do not use salt to clean the kettle This will scratch the surface If using salt water to cook shellfish be sure to rinse and wash the kettle thoroughly after use Bring milk and egg products slowly up to tempera ture in a cold kettle to prevent product from adhering to the sides When preparing milk based products do not preheat the kettle When planning actual cooking capacity allo...

Страница 11: ...rd surfaces as it can be damaged and cause valve leakage Wash the valve stem disk and handle Insert a nylon brush wet with detergent and water into the valve body and tangent draw off tube Brush vigorously 2 Replace the valve stem assembly and turn the hex nut until snug Rinse the kettle with clean warm wa ter 3 Leave the draw off valve open when the kettle is not in use Dairy Draw Off Valve Clean...

Страница 12: ...on the metal in the direction of the polishing lines Rubbing cleanser as gently as possible in the direction of the polished lines will not mar the finish of the stainless steel NEVER RUB WITH A CIRCULAR MOTION Soil and burn deposits which do not respond to the above procedure can usually be removed by rubbing the surface with SCOTCH BRITE scouring pads or STAINLESS scouring pads DO NOT USE ORDINA...

Страница 13: ...ir vent should be cleansed if an accumulation of dust or lint is obvious Twice a Year minimum 1 Have an authorized service person clean and adjust the unit for maximum performance 2 The unit venting system should be examined and cleaned 3 Grease the screw jack tilt mechanism via the lubricat ing nipple Use Petro Canada type OG 2 or equiva lent Annually 1 Have an authorized service person inspect t...

Отзывы: