4

INSTALLATION

Kettle Installation & Utility Connection

KETTLE INSTALLATION

1.  Uncrate carefully.  Report any hidden freight damage 

to the freight company immediately.

2.  The pressure relief valve is located at the right rear of 

the unit.  This area should be kept clear and should 

not be in an area where operators will normally stand.  

The elbow on the relief valve should be turned toward 

the floor.  A maximum 3 foot, 3/4” diameter pipe may 

be used to extend to the floor, but must not be piped 

directly to a drain.  It must vent to the atmosphere.  

3.  Set the unit in place.  Be certain to maintain minimum 

clearances as stated above.

4.  To level the unit use a spirit level in all directions on 

the top of the kettle (lid up).  Adjust the bottom foot on 

each leg to overcome an uneven floor.

5.  Mark hole locations on floor through anchoring holes 

provided in flanged adjustable feet.

6.  Remove appliance and drill holes in locations marked 

on floor and insert proper anchoring devices.

7.  Set unit back in position and re-level left to right and 

front to back.

8.  Bolt and anchor appliances securely to the floor.
9.  Seal bolts and flanged feet with silastic or equivalent 

compound.

10. Appliance location must allow air supply to unit and 

obstruction free clearance for air opening into the 

combustion chamber.

11.  Make service connections as indicated.
12. Check the pressure gauge on the front panel before 

operating.  If the pressure gauge does not indicate 

green vacuum zone (below 0 psi), see “Re-establish-

ing Vacuum” section under SERVICE, after complet-

ing installation instructions.

GAS CONNECTION

The serial plate on the lower right side of the unit indicates 

the type of gas your unit is equipped to burn.  Do NOT 

connect to any other gas type.
A 3/4” NPT line is provided at the rear for the connection.  

Each unit is equipped with an internal pressure regulator 

which is set for 3.5” W.C. manifold pressure for natural 

gas and 4.0” W.C. for propane gas.  Use 1/8” pipe tap on 

the downstream side of the combination valve for check-

ing pressure.

An adequate gas supply is imperative.  Undersized or low 

pressure lines will restrict the volume of gas required for 

satisfactory performance.  A steady pressure, minimum 6” 

W.C. for natural gas and minimum 11” W.C. for propane 

gas, is recommended.  With all units operating simultane-

ously, the manifold pressure on all units should not show 

any appreciable drop.  Fluctuations of more than 25% 

on natural gas, and 10% on propane gas, will create pi-

lot problems and affect burner operating characteristics.  

Contact your gas company for correct supply line sizes.  
Purge the supply line to clean out any dust, dirt, or other 

foreign matter before connecting the line to the unit.  It is 

recommended that an individual manual shut off valve be 

installed in the gas supply line to the unit.  Use pipe joint 

compound which is suitable for use with LP gas on all 

threaded connections.  Test pipe connections thoroughly 

for gas leaks.

   WARNING

All connections must be checked for leaks, 

after the unit has been put in operation.  Use 

soapy water only for testing on all gases.  

Never use an open flame to check for gas 

leaks.

 NOTICE

If applicable, the vent line from the gas appli-

ance pressure regulator  shall be installed to 

the outdoors in accordance with local codes 

or, in the absence of local codes, with the Na-

tional Fuel Gas Code, ANSI Z223.1/NFPA 54, or 

the Natural Gas and Propane Installation Code 

CSA B149.1, as applicable.

 NOTICE

If this equipment is being installed at over 

2,000 feet altitude and was not so specified on 

order, contact service department.  Failure to 

install with proper orifice sizing may void the 

warranty.

Содержание FT-40GLS

Страница 1: ...FT 40GLS SHORT HEIGHT GAS TILTING KETTLE INSTALLATION OPERATION MAINTENANCE Telephone 802 658 6600 Fax 802 864 0183 www marketforge com PN 14 0573 Rev A 4 15 2015 Market Forge ...

Страница 2: ...Your Service Agency s Address Model Serial number Kettle installed by Installation checked by ...

Страница 3: ... before in stalling or servicing this equip ment INSTRUCTIONS TO BE FOL LOWED IN THE EVENT THE USER SMELLS GAS MUST BE POSTED IN A PROMINENT LO CATION This information may be obtained by contacting your local gas supplier FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance Do not obstruct the flow of com bustion and venti...

Страница 4: ...STALLATION CLEARANCE Left Side Right Side Rear 0 0mm 0 0mm 4 102mm BTU Hour 125 000 kW Hour 36 63 Gas Supply Supply Pipe Pressure W C Natural 6 14 152 356mm Propane 11 14 279 356mm Use on non combustible floors only Shown with option faucet cover and draw off Ø7 16 11mm HOLES 2 EQUALLY SPACED ON 2 5 63mm B C REAR FLANGED FOOT DETAIL 6 38 162 36 914 WATER LEVEL PRESSURE COOK TEMP LOW WATER COOKING ...

Страница 5: ...led at an angle of 45 degrees or more with the horizontal This position prevents drip ping of grease and facilitates collecting the run off grease in a drip pan usually installed with the filter A strong ex haust fan tends to create a vacuum in the room and may interfere with burner performance or may extinguish pilot flames Makeup air openings approximately equal to the fan area will relieve such...

Страница 6: ...other gas type A 3 4 NPT line is provided at the rear for the connection Each unit is equipped with an internal pressure regulator which is set for 3 5 W C manifold pressure for natural gas and 4 0 W C for propane gas Use 1 8 pipe tap on the downstream side of the combination valve for check ing pressure An adequate gas supply is imperative Undersized or low pressure lines will restrict the volume...

Страница 7: ...ounded receptacle A separate 15 amp supply is needed for each unit 2 208 240 VAC 60 Hz Single and Three Phase Units with this electrical rating are factory equipped with a transformer To connect supply wires remove cover from right console Route supply wires and ground wire through the hole in the console with a strain relief fit ting Connect wires to the terminal block in the rear of the right co...

Страница 8: ...ght posi tion turn power switch ON 3 Set thermostat to maximum initiating a 30 second pre purge Red COOKING pilot will come on and after 30 seconds the green IGNITION pilot will come on lighting the main burners If after 36 seconds the burner fails to ignite or the ignition light goes out the system goes into Safety Lockout De energize the system by setting the ther mostat to OFF for five minutes ...

Страница 9: ...at must be set at a desired setting in order for the burner to ignite For Reference DIAL SETTING C F 1 15 60 2 27 81 3 40 104 4 53 127 5 67 153 6 81 178 7 95 203 8 108 226 9 122 252 10 135 275 PRESSURE GAUGE The pressure gauge indicates the internal operating pres sure of the kettle When cold the gauge should point to the green vacuum zone If it does not refer to Re estab lishing Vacuum section Un...

Страница 10: ...o prevent pitting Do not use salt to clean the kettle This will scratch the surface If using salt water to cook shellfish be sure to rinse and wash the kettle thoroughly after use Bring milk and egg products slowly up to tempera ture in a cold kettle to prevent product from adhering to the sides When preparing milk based products do not preheat the kettle When planning actual cooking capacity allo...

Страница 11: ...rd surfaces as it can be damaged and cause valve leakage Wash the valve stem disk and handle Insert a nylon brush wet with detergent and water into the valve body and tangent draw off tube Brush vigorously 2 Replace the valve stem assembly and turn the hex nut until snug Rinse the kettle with clean warm wa ter 3 Leave the draw off valve open when the kettle is not in use Dairy Draw Off Valve Clean...

Страница 12: ...on the metal in the direction of the polishing lines Rubbing cleanser as gently as possible in the direction of the polished lines will not mar the finish of the stainless steel NEVER RUB WITH A CIRCULAR MOTION Soil and burn deposits which do not respond to the above procedure can usually be removed by rubbing the surface with SCOTCH BRITE scouring pads or STAINLESS scouring pads DO NOT USE ORDINA...

Страница 13: ...ir vent should be cleansed if an accumulation of dust or lint is obvious Twice a Year minimum 1 Have an authorized service person clean and adjust the unit for maximum performance 2 The unit venting system should be examined and cleaned 3 Grease the screw jack tilt mechanism via the lubricat ing nipple Use Petro Canada type OG 2 or equiva lent Annually 1 Have an authorized service person inspect t...

Отзывы: