GEnEral troublshootinG GuidE
problEm
probablE causE
rEmEdY
DOOR LEAKS.
a. Damaged door gasket.
b. clogged compartment drain.
a. check gasket for cuts and replace.
b. Remove screen and clean drain line
or plumbing.
WATER FLOWS inTO
cOOKing cOmPARTmEnT.
a. Level control has failed.
b. Water has very high resistance
c. Scale build-up on probe.
d. Water fill solenoid valve.
a. Replace.
b. Replace level control with high sen-
sitivity control.
c. clean all probes
d. Plugged, defective, clean or re-
place.
NOTE: THESE PROBLEMS ARE AN INDICATION OF SEVERE WATER CONDITIONS WHICH SHOULD BE COR-
RECTED IMMEDIATELY TO AVOID DAMAGE TO THE COMPONENTS AND PERFORMANCE OF THE
STEAMER. CALL YOUR SERVICE AGENCY FOR ASSISTANCE.
WATER AccUmULATES in
cOmPARTmEnT.
a. Plugged compartment drain
a. Remove screen and clean drain
line.
WATER FLOWS inTO DRAin
DURing ShUTDOWn.
a. cooling valve does not close.
a. check valve for foreign material or
damage.
WATER nOT BEing SUP-
PLiED TO gEnERATOR.
a. Water supply off.
b. Supply water pressure too low.
c. Defective water solenoid valve.
d. Level Probe shorted.
e. Defective water level control.
f. Drain valve is open.
a. check incoming water valve is on.
b. call supply agency.
c. Replace or clean.
d. check and correct.
e. Replace.
f. check valve, clean or replace.