![Mark SIDIUS LED 285/4 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/mark/sidius-led-285-4/sidius-led-285-4_user-manual_1727543008.webp)
7.2
Power Connection
The equipment must be operated by professionals; Make sure that the voltage of
power supply must be comply with the voltage identified on the device, and must have an
overload or leakage electrical protection.
ATTENTION!
The equipment directly connected to the power supply.
Factory has equipped the standard 3 pin plug socket. Connect the power supply as below table.
Yellow and green wire could be connect to ground.
If the cable of the fixture is damaged, replacement should be operate by factory or qualified staff.
Wire Colour
Plug
Mark
Brown
Live wire
L
Blue
Null
N
Green
Ground wire
8.
CONTROL PANEL MENU OPERATE
1: The indicating arrow in the right below is enter the menu (click the menu).
2: The touch screen display have four operation key : Exit, Upward, Downward, Enter, press it will
execute orders accordingly.
3: Can change the parameter Settings directly on the touch screen
4: Also can use the wheel on the left side of touch screen to change the parameter Settings
5: The equipment have built-in temperature sensor, the temperature will display
on the bottom left
corner of touch screen. When over the rated temperature, the equipment will start the automatic
protection function.
6: When the equipment receive the DMX512 signal,the blue ligh t on the top right lights up, the
left side show have connected the XLR Socket.
.
CONTROL PANEL MENU OPERATE
Address
DMX Address number set
001-512
Transfer Rate
029
Data
506
Signal quality
100%
Start Code
000
Fixed ID set
0-4096
Return
Special
White Balance
Off
SIDIUS LED 285/4 User Manual/Manual de uso 7
EN