4.1 ANTI -HIGH TEMPERATURE

 

t

a

 =40°C 

Please don’t use the equipment if the temperature above 40

 

 

4.2 TO PREVENT FALLING WOUNDING  

 

When Hang the fixture, please must verify that the facilities to be able to withstand at least 10 

times or more weight of fixtures.

 

Please make sure the Mounting hardware is strong enough no any damage, and insurance for

 

the safety rope as auxiliary security fixed in other facilities will need to verify before installation. 

Installing or removing the equipment, to make the pulley below the work location

 

 

4.3 UA PROTECTION  

 

  Forbid straight viewpoint with exposed bulbs to avoid UV damage to the eyes;

 

Do not use the equipment without the lens screen and the lid;

 

The lens and the light head covers should be timely replaced if any damage to rupture

 

4.4 PREVENTION OF ELECTIC SHOCK  

 

The electrical connection must only be carried out with corresponding qualifications;

 

Before  installing,  make  sure  you  use  the  power  voltage  must  comply  with  the 

identified power, voltage and have an overload or leakage protection;

 

Each fixture must be properly grounded, installed in accordance with the relevant standards; 

Cut off the power when stall or replace the lamp and the fuse; 

 

Forbid using the fixture in storm or wet environment.

 

 

4.5 TO PREVENT BURNING OR FIRE

 

     1. The fixture can't be mounted directly on the surface of ordinary combustible material.

 

2. The equipment must be installed away from inflammable and explosive materials.

 

3. The highest temperature is 40 ° C when the equipment is in stable state.

 

4. The equipment can not have an obstacle at least in the range of 0.5 meters. 

5. Do not replace the non-original parts. 

 

5. Packing and Shipping

 

5.1 ATTACHMENT 

Attach follow accessory.

 

    

Content 

Quantity 

User Manual

 

DMX Cable 

Safety Rope( charge)

 

SIDIUS LED 285/4            User Manual/Manual de uso       3

EN

Содержание SIDIUS LED 285/4

Страница 1: ...Rev 15 06 01 SIDIUS LED 285 4 User Manual Instrucciones de Usuario...

Страница 2: ...justment rich color changes Through the menu calls the built in program for scenario editor and setting sound master slave control mode can do rainbow variable strobe and electric dimming effect SIDIU...

Страница 3: ...IP20 protection class Lamps should be kept dry to avoid Moisture overheating or dusty environment Prevent lamps come into contact with water or any other liquid Please read the instructions before use...

Страница 4: ...The electrical connection must only be carried out with corresponding qualifications Before installing make sure you use the power voltage must comply with the identified power voltage and have an ov...

Страница 5: ...is a secure connection Please let professionals to checkits electrical parameters before installation Make sure the related experts check these installation once a year 6 1 Rigging Installation SIDIUS...

Страница 6: ...10 times the weight of the equipment 5 Make sure the X Y protect locks are opened Verify that within 0 5 meters there is no combustibles 6 3EQUIPMENT CONNECT Attention One product only can accept one...

Страница 7: ...he 2 and 3 pin of 3pin or 5 pin socket 6 4CABLE CONNECTION Connect the DMX data from the controller to the nearest controller equipment 3pin or 5pin socket and then from this equipment output connecte...

Страница 8: ...is enter the menu click the menu 2 The touch screen display have four operation key Exit Upward Downward Enter pressit will execute orders accordingly 3 Canchange the parameter Settings directly on th...

Страница 9: ...Annu Return InfoSee Total Tim 00048 00 WorkHour 00000 03 Times 0000 61 ClearTim ClearTim Touch Screen_ Control Vtft 01 Software version XY _Control Software version LED _Control Software version Retur...

Страница 10: ...de Simple mode Standard mode Extended mode 9 Each led RGBWcan be individual control 256 level of brightness control 10 With sound and master slave mode control function Many strobe and rainbow effect...

Страница 11: ...Green Fine Channel 5 Channel5 Channel 5 0 255 Blue darkest brightest Channel 6 Channel6 Channel 6 0 255 Blue F ine Channel 7 Channel7 Channel 7 0 255 White darkest brightest Channel 8 Channel8 Channel...

Страница 12: ...lour 34 MediumPink 185 189 Colour 35 LightPink 190 194 Colour 36 SunriseRed 195 199 Colour 37 DarkAmber 200 204 Colour 38 MediumAmber 205 215 Colour Forward Jump Fast Slow 216 228 Colour Forward Jump...

Страница 13: ...0 255 LED graphic display Channel22 Channel22 0 255 Auto program selection Channel23 Channel23 0 255 Auto program speed setting Channel24 Channel24 0 255 Auto program fade in Channel25 Channel25 0 25...

Страница 14: ...be clean gently coating surface is very fragile it is easy to scratch keep theacrylic plateclean or will affect the brightness of the fixture don t use destructive solvent otherwise it will damage the...

Страница 15: ...ejecuci n por audio o mediente el modo master slave dispone adem s de efecto rainbow strobo variable y dimmerizaci n SIDIUS LED 285 4 dispone de una r pida respuesta de movimiento es resistente a los...

Страница 16: ...idad compruebe el embalaje por si ha sufrido da os durante el transporte Si detecta da os no utilice la unidad y contacte inmediatamente con su distribuidor lo antes posible Este producto est dise ado...

Страница 17: ...via No se exponga a la luz directa de la fuente lum nica para evitar da os en los ojos No se esta unidad sin las lentes que integra Las lentes y cubiertas deben ser reemplazadas si sufren da os La con...

Страница 18: ...ci n no permanezca debajo Aseg rese que la unidad est correctamente fijada Por favor deje en manos de profesionales las comprobaciones de conexionado el ctrico SIDIUS LED 285 4 puede situarse sobre un...

Страница 19: ...0 veces el peso del dispositivo 5 Aseg rese que las protecciones de bloqueo X e Y est n abiertas Verifique que no hay meteriales combustibles a 0 5 m a la redonda del dispositivo ATENCION Este product...

Страница 20: ...minador consiste en una resistencia de 120 ohm soldada entre los terminales 2 y 3 del conector Conecte el cable DMX Desde la salida del controlador a la entrada DMX del dispositivo m s cercano a la to...

Страница 21: ...e 3 polos Conecte los cables como indica la tabla adjunta El cable amarillo verde debe ser conectado a tierra Si el cable se da a debe ser sustituido por personal cualificado 1 La flecha indicadora de...

Страница 22: ...xec Annu Return InfoSee Total Tim 00048 00 WorkHour 00000 03 Times 0000 61 ClearTim ClearTim Touch Screen_ Control Vtft 01 Software version XY _Control Software version LED _Control Software version R...

Страница 23: ...puede controlarse individualmente 256 niveles de brillo 10 Funci n de control por audio o master slave 11 Efectos strobo y rainbow Varios programas incorporados en modo sencillo Cada color y gobo pued...

Страница 24: ...nal 6 0 255 Azul fino Canal 7 Canal 7 Canal 7 0 255 Blanco Canal 8 Canal 8 Canal 8 0 255 Blanco fino Canal 9 Canal 9 Canal 9 0 255 Control temperatura de color Canal 10 Canal 10 Canal 10 Color macro 1...

Страница 25: ...n 18 0 184 Color 34 Medium Pink 185 189 Color 35 LightPink 190 194 Color 36 Sunrise Red 195 199 Color 37 Dark Amber 200 204 Color 38 Medium Amber 205 215 Color Adelante r pido lento Adelante lento r p...

Страница 26: ...to program speed setting Canal 24 Canal 24 0 255 Auto program fade in Canal 25 Canal 25 0 255 Auto program Red Canal 26 Canal 26 0 255 Auto program Green Canal 27 Canal 27 0 255 Auto program Blue Cana...

Страница 27: ...entos pticos Los componentes pticos deben ser limpiados con cuidado ya que la superficie es fr gil y es f cil que se raye Mantenga la placa acr lica limpia para que no se vea afectada por el brillo de...

Страница 28: ...EQUIPSON S A Avda El Saler 14 Pol Ind L Alter 46460 Silla Valencia Spain Tel 34 96 121 63 01 Fax 34 96 120 02 42 www equipson es support equipson es...

Отзывы: