Mark 0662551 Скачать руководство пользователя страница 19

19

10.4 Disassembly FBA-K Ultra

1. Turn off the main switch and lock it.
2. Remove the power supply and electrical connection 
in the junction box “K”.
3. Close the hot water supply.
4. Remove the condensate hose.
5. Disassemble the heating medium.
6. Loosen the ceiling screws and remove the unit.
7. Loosen the grid on the left and right of the pump.
8. Remove the pump from the holder plates.
9. Remove the sheet metal screws 

[1]

 (12x).

10. Remove rear with attached fan, unit is now still 
attached to rear wall.
11. Remove fixing screws 

[2]

 (3x) for heater.

12. Remove the heater and the mounting plates.

10.5 Removal and destruction
To disassemble the air heater it must be without power. All power cables must be removed by a 
qualified electrician. 
More-over, all fluid-carrying parts must be completely empty. This must be done by a professional 
company that properly draines the water with anti-freeze.
After that, the air heater can be disassembled at the scene. This should also be carried out by a 
specialised company that has knowledge of the environmentally friendly removal of parts. 

In the handling of dust-sensitive components (filters) and parts of mineral wool it is wise to wear appropriate 
respiratory protection. 

Destruction

In our FBA devices, the following material is used:

Housing and attachments:
• 

Galvanized steel

• 

Stainless steel 1.4301

• 

Aluminum AIMg

• 

Copper

Sealants:
• 

Polyurethane waste code: 55908, 080404

Isolation material:
• 

Mineral wool waste code: 31416

• 

Soundproofing

All materials can be disposed through the appropriate waste collection services.

 EN

Содержание 0662551

Страница 1: ...Technical manual EN MARK TANNER FBA ULTRA 0662551...

Страница 2: ...2...

Страница 3: ...hat they do not play with the appliance Index 1 Intended use 4 2 Safety 5 3 Receiving of the goods 6 3 1 Damage in transport 6 3 2 Transport packaging 6 4 Mounting 6 4 1 Ceiling mounting 6 4 2 Mountin...

Страница 4: ...are suitable for Transport of air that is Dust free Without harmful substances Non agressive Non corrosive Not flammable Purification of air for Filtering Heating Cooling Consultation with or consent...

Страница 5: ...stopped The components have been cooled down to room temperature Note Only qualified personnel should perform maintenance on the electrical components Consider the local regulations Changes or additi...

Страница 6: ...4 1 Ceiling mounting Fastening the FBA device to the ceiling must be done with officially approved fasteners In the dimensioning of the fastening the following gear weights should be taken into accoun...

Страница 7: ...on the outside to prevent condensation 4 3 Roof mounting The mounting of roof accessories raincover or channels can be performed at the scene Slabs are not included 4 4 Louvre adjustment When adjustin...

Страница 8: ...heat exchanger When decommissioning the frost protection thermostat should be connected to the air outlet side of the heat exchanger 4 6 Air valve and drain valve When using an air valve you must mak...

Страница 9: ...ing unit 685 52 54 E TK Thermocontact TK Thermocontact Fan engine 1 Fan engine 2 o X TK Thermocontact TK Thermocontact Fan engine 1 Fan engine 2 o X Switching unit 685 55 58D 683 56D 58D 7 wire 7 wire...

Страница 10: ...5 685 55D 5 2 1 685 56D 10 4 2 685 57D 20 8 5 685 58D 35 14 10 5 wire 5 wire 9 wire 4 wire 4 wire 9 wire RT Room thermostat TK Thermocontact RT Room thermostat TK Thermocontact Location supply fuses...

Страница 11: ...ocontact Location supply fuses 1 U 2 U 11 685 54E 12 14 N L L RT RT 250 V AC max 2A 250 V AC max 1A RT FS FS TK TK L1 N FS TK M 1 1 U 2 U 11 685 52 53E 12 14 1 2 3 6 7 250 V AC max 2A 250 V AC max 1A...

Страница 12: ...ostat and actuator on off 517 Switching unit Position 0 Servomotor Position Closed Position 0 Servomotor Position Closed 13 14 21 22 13 14 21 22 707 OPEN CLOSE N 14 12 671 N 685 54 E 685 55 58 D 1 2 6...

Страница 13: ...will end the warranty of the engine Important switching capacity 10 A with cos 1 0 6 A with cos 0 6 Voltage 250 V Voltage power 2000 V eff If the engine protection is in operation the engine can only...

Страница 14: ...of engines switches and other electrical accessories should be done in accordance with the relevant standards VDE 0100 EMC act rules of RU For speed control a frequency converter cannot be used since...

Страница 15: ...ordance with the technical data The condensate pump lies in the drip tray In the inlet of the pump a round filter has been inserted See figure 2 The condensate pump is designed for continuous use For...

Страница 16: ...he filter must definitely be cleaned or if necessary replaced In the abscence of maintenace the warranty expires 9 Maintenance 9 1 Warranty Our warranty does not cover damage caused by improper use or...

Страница 17: ...the heat exchanger by blowing compressed air onto it Take care of oil containing dust with an oil soluble detergent Use a steam cleaner to remove sticky surface Note Use low pressure as well as an in...

Страница 18: ...g screws and remove the unit 8 Disassemble the rear wall after screws on position 4 4x position 3 3x and if necessary position 1 3x have been removed and remove the engine 9 Pull the heat exchanger fr...

Страница 19: ...er cables must be removed by a qualified electrician More over all fluid carrying parts must be completely empty This must be done by a professional company that properly draines the water with anti f...

Страница 20: ...ELGIQUE TELEFOON 32 0 3 6669254 FAX 32 0 3 6666578 info markbelgium be www markbelgium be MARK DEUTSCHLAND GmbH MAX PLANCK STRASSE 16 46446 EMMERICH AM RHEIN DEUTSCHLAND TELEFON 49 0 2822 97728 0 TELE...

Отзывы: