12
5.9 Change language selection
Language options: NL, EN, DE, FR, IT, PL, RO, LT.
5.10 Calibration
If the assembly site is not suitable for the external sensor, a defect may occur in the temperature
actually measured by the PinTherm Infra II. This temperature difference can be compensated by
setting a correction value with this calibration function.
Example: The temperature measured amounts to 18°C, the screen on the PinTherm Infra II
indicates 20°C. The difference in this example therefore amounts to 2°C too high
the correction value must therefore be set to -2°C.
5.11 Changing high/low setting
High/low setting can be adjusted to
- High/low manual
- High/low automatic 1K
- High/low automatic 2K
- High/low automatic 3K
In the automatic position, the Infra will automatically go 1.2 or 3K under the required
temperature to operating position low.
ENGLISH
SELECT LANGUAGE
back to the
menu
select the desired
language
select
OK
OK
CHANGE LANGUAGE
CALIB. TEMP.
CALIB. TEMP.
Correctionvalue is adjustable
back to the
menu
select
changes the
flashing digit
to go one digit up
OK
OK
+ 0.0°C
from -3,5°C to +3,5°C
back to the
menu
select
change setting
OK
SETTING
HIGH/LOW
HIGH/LOW
MANUAL
OK