![Mark 7 DecapSense 1050 Super Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/mark-7/decapsense-1050-super/decapsense-1050-super_instruction-manual_1727609003.webp)
DECAPSENSE INSTRUCTION MANUAL VERSION 1.1
3
Set-Up Procedures:
1.
Remove the spent primer bin and bracket on the 1050.
2.
Install the Mark 7®
DecapSense™
and check for proper fit/alignment.
We recommend partially fastening the Mark 7® DecapSense™ to the 1050, rem
ove the
sizing die if installed in the tool head and move to the bottom position. Visually check
alignment of the mount to the decapping through hole in the press frame. Due to
variations in the 1050 casting some filling/sanding may be required on the mount to
ensure proper alignment.
3.
Attach the hose to the output fitting and route into a bucket or other spent primer collection
container.
4.
Plug the Mark 7®
DecapSense™
Cable into port #5 on the console.
Figure 1: Port Diagram