4.1.6.1 Automatic calibration
Function not used
You can switch this function OFF and use the manual calibration command.
4.1.7 Align (ST7)
Alignment error adjustment should be done by taking a couple of known runs from a
chart and compare the magnetic heading with the mag. heading shown on the
display. The difference can be compensated by setting the Align value.
x
Press SET and up/down to select the Align menu (ST7). Press SET to enter
the menu. Use the up/down buttons to set the offset. This can be set in steps
of 0.1° up to +/- 99°.
To exit the menu press SET once or keep SET pressed for two seconds to exit to the
default view.
4.1.8 Variation (ST8)
The Variation can be set to compensate the magnetic heading so that the display
shows the geograpical (True) heading.
x
Press SET and up/down to select the Variation menu (ST8). Press SET to
enter the menu. Use the up/down buttons to set the offset. This can be set in
steps of 0.1° up to +/- 45°.
To exit the menu press SET once or keep SET pressed for two seconds to exit to the
default view.
4.1.9 Error messages
No data input
: The
CD110
has not received data for more than 5 seconds,
Please check the connections
No response
: No response after send a command:
x
Check the connections or another not fully compatible
compass is connected.
Compass
Display CD110