How to activate the device when armed
When the sMRT V100/V100X is armed in the
[READY]
position, it
can activate as follows:
1. Automatically via the water sensor after
2
seconds of
continuous immersion.
2. Automatically when the PFD inflates in an emergency.
Note: When the PFD inflates it removes the
ACTIVATION
TAB
from the sMRT V100/V100X and automatically activates
the device.
3. Manually by removing the
ACTIVATION TAB
from the device.
Device indications after activation
When activated, the sMRT V100/V100X features a 10 second
warning period, during which:
1. The
PIEZO
beeps initially for two seconds (excluding V100X), and
2. The
LEFT LED
blinks blue and
RIGHT LED
illuminates solid
blue.
After the 10 second warning period the sMRT V100/V100X will
commence AIS and emergency VHF DSC transmissions. The
internal GPS receiver will acquire a position within approximately
one minute of activation and the device can then send VHF DSC
and AIS transmissions containing the casualty’s current position.
The
STROBE
light on the device flashes once per second to assist
with visual homing at night or in poor weather conditions.
Содержание sMRT V100
Страница 24: ...sMRT V100 V100X User Manual v1 0 MRT Ltd 2014 24 7 sMRT V100 Declaration of Conformity ...
Страница 26: ...sMRT V100 V100X User Manual v1 0 26 MRT Ltd 2014 9 TRaC ATEX IECEx Certification ...
Страница 27: ...sMRT V100 V100X User Manual v1 0 MRT Ltd 2014 27 ...
Страница 38: ...sMRT V100 V100X User Manual v1 0 MRT Ltd 2014 38 Notes ...
Страница 39: ...sMRT V100 V100X User Manual v1 0 MRT Ltd 2014 39 Notes ...