8
4.1.4
Cold start: Turn the starter key to position ON. The lamps of REV meter and oil pressure
light up.
4.1.5
Press the test button to make sure that the alarm is working.
4.1.6
Turn the starter key to position 1, the solenoid will release the fuel pump.
4.1.6
Turn the starter key to position heater and keep for 3 seconds, turn the key to position start,
the start motor will work, release the key when the engine has started. When the engine is running, the
key should be in position 1. Before restarting the engine, return the key to position OFF.
4.1.7
Immediately after starting the engine, check that the oil pressure lamp and
water temperature lamp and that alarm is not sounding, if the alarm is sounding, stop the engine
immediately and investigate the case.
4.1.8
If the engine temperature or oil pressure lamps light up and alarm sounds, either the engine
temperature is too high or the oil pressure is too low, and you should stop the engine and
investigate the case.