– Place the O-ring back on the quartz glass casing and insert the quartz glass
casing into the head of the device until you reach the stopper. The O-ring must
be pushedinto the gap between the head of the device and the quartz glass. The
O-ring is then pushed into the right position using of a retaining bolt.
– Check the O-ring on the head of the device for damage, and adjust its placement.
– Carefully push the head of the device into the appropriate casing.
– By exerting a mild pressure, turn the head of the device in the direction opposite
to that indicated by the arrow until you reach the stopper.
– First re-commission the filtration device, and then plug the power plug of the UV
lamp into the appropriate power source.
Error localization
Turbid water can have several causes: ―> solution
• The UVC lamp does not turn on. ―> Check the electrical wiring
• The quartz tube is not clean. ―> Clean it
• Incorrect pump flow. ―> Check the installation
• Brown suspended particles, deposits on the bottom ―> Remove algae and leaves,
prevent dirt from entering
• The pool is extremely dirty. ―> Check the water quality, replace the water
• The lamp has no UVC output. ―> Check the lamp, replace the lamp after 6,000
operating hours
Warranty conditions
– The UV lamp is made of the highest quality materials and high quality finish. All
parts have been inspected and found to be unsafe. The warranty is valid for two
years from the date of purchase. Keep all purchase documents together with the
instructions. Proof of purchase will be required when applying warranty claims.
– Complaints of goods are governed by the Czech legal order.
– The buyer is obliged to check whether the transport packaging is damaged or that
the product is otherwise damaged or damaged and immediately inform the seller
immediately after purchasing the UV lamp.
– If the UV lamp shows obvious defects that occur immediately after commissioning
and for which it can not be used, the Buyer is obliged to complain immediately.
– If a fault is detected on the individual parts of the UV lamp, complain only that the
defective part with the visible location of the damage is damaged.
The warranty does not apply to:
– wear due to improper installation or improper use, improper storage
– normal wear and tear of a device corresponding to the nature and duration of its
use
– defects caused by mechanical damage
– defects caused by the influence of natural forces