Marey SANTON Скачать руководство пользователя страница 3

04

05

Thank  you  for  purchasing  a  Marey  Power  Pack.  The  Power  Pack  unvented 
pressure system water heater is manufactured to the highest standards and has 
been designed to meet all the latest relevant safety specifications.

This Power Pack water heater must be installed, commissioned and maintained by 
a  competent  person.  Please  read  and  understand  these  instructions  prior  to 
installing  your  Power  Pack  unvented  pressure  system  water  heater.  Particular 
attention should be paid to the section headed SAFETY. 

This appliance is not intended for use by persons (including children) with reduced 
physical,  sensory  or  mental  capabilities,  or  lack  of  experience  and  knowledge, 
unless they have been given supervision or instruction concerning the use of the 
appliance by a person responsible for their safety. Children should be supervised to 
ensure that they do not play with the appliance.

Heater
Fixing screws and plugs
Installation and User Instructions

Connections:

Inlet / Outlet connection -1/2" BSP 
Water entry point - bottom 
Cable entry point - bottom/rear

Electrical:

Model numbers 
7.0kW - 94 805 005 
9.0kW - 94 805 006
Electrical rating................................................................. 6.4/7.0kW @ 230/240V
..........................................................................................8.3/9.0kW @ 230/240V

Rated Pressure:

7kW/9kW

Materials:

Back plate, cover - ABS 
Element(s) - Copper sheathed rod type.

Dimensions: 

Height - 8.27" - 210mm
Width - 6.30" - 160mm
Depth - 4.33" - 104mm

Standards and Approvals: 

Complies with the requirement of UL. 
Complies with European Community Directives (CE). 

MODEL

TEMPERATURE RISE AT FLOW RATE  IN U.S. GALLONS

A.C. ONLY

0.5 GPM

0,75 GPM

1.0 GPM

1.5 GPM

2.0 GPM

2.5 GPM

WATTS

VOLTS

AMPS

WIRE 

SIZE

94 805 

005

95º F

63º F

47º F

31º F

23º F

19º F

7000

240

29.2

8AWG

94 805 

006

123º F

82º F

61º F

41º F

30º F

24º F

9000

240

37.5

6AWG

Fig. 01

Содержание SANTON

Страница 1: ...ELECTRIC HEATER INSTRUCTION MANUAL SANTON MODEL by Keep this manual with you after your unit has been installed you may need it for further technical information...

Страница 2: ...chased a new Santon tankless water heater and will soon begin to enjoy the benefits of going tankless Take the time to thoroughly read and understand this safety and installationmanualinitsentiretybef...

Страница 3: ...the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance Heater Fixing screws and plugs Installation and User Instruction...

Страница 4: ...being frozen See fault finding table 2 4 These heaters are of the closed outlet type unvented pressure system and are suitable for connection to normal cold water mains supplies up to a maximum of 0 5...

Страница 5: ...trical Requirements 3 6 This appliance must be earthed 3 7 The installation must comply with national local code of practices and Electricity SupplyAuthorities requirements All rules and requirements...

Страница 6: ...it can be difficult once joints have been made 4 9 An isolating stop valve MUST be incorporated to the main water supply to comply with Water Regulations 4 10 Assemble the installation before making...

Страница 7: ...ater flow too low Increase the flow by turning the water control A Electrical power to the power pack heater is off Ensure that the electronics to the power pack is switched on the neon is lit B Water...

Страница 8: ...l SwitchAssembly 95 613 004 5 Power Pack Cover 95 614 107 6 NeonAssembly 95 615 058 7 Inlet BossAssembly 95 607 106 8 Outlet BossAssembly 95 607 109 15 14 Fig 07 MINI MAREY AQUAMATIC POWER GAS SANTON...

Отзывы: