After power is supplied a beep can be heard. Turn on hot water faucet unit will activate

upon water flow, display should show actual outlet temperature. Push power button if

unit does not change due to water flow. Set desired temp with the up and down arrows.

Test water to prevent scalds.

4) Operation

Plot the three holes for the mounting screws onto the wall. Mount vertically on a flat

surface (i.e. board or walI) larger than the unit itself. Make sure heater is secure by

utilizing a stud or the provided wall anchors. Keep away from any potential splashing or

leaking water and strong magnetic fields.

Plumbing connections are ½" NPT, and both the inlet and outlet can be found at the

bottom of the unit. When installing your water connections make sure to use ½" NPT

fittings. Please use the provided gaskets to prevent leaks. When tightening fittings, use

a back-up wrench on inlet and outlet fittings (flat sides of fittings are located behind

front cover). The cold water inlet is on the right side it should be preceded by a high

pressure discharge valve and a shut off valve in that order. The hot water outlet is on the

left side and runs to your hot water source. NEVER USE PVC ON HOT WATER

OUTLET. Use instead CPVC or other high temperature rated materials. Run water

through the heater for a few minutes to purge all air from the system. Shut off flow at

faucet to pressurize system. At this point check for and fix any leaks. If no leaks are

present move to next step.

Power wires and ground come into the unit from the upper right hand side of the back

 

panel. Use 6 AWG for your ground wire, running from the "E" space in the terminal

 

block all the way to the ground bar of the breaker panel. Run one 6 AWG wire from

 

each of the "L1" and "L2" connection points of the terminal block to the double pull 

50 

amp breaker at your panel.

3) Electrical Connections

2) Water Connections

1) Mounting

ECO110

QUICK START GUIDE

04

Содержание ECO110

Страница 1: ...is manual with you after your unit has been installed you may need it for further technical information ECO110 ELECTRIC TANKLESS WATER HEATER INSTRUCTION MANUAL USA 855 627 3955 PR 787 727 0277 www ma...

Страница 2: ...this safety and installation manual in its entirety before you attempt to install your new ECO11O tankless water heater as it contains important safety tips and instructions Please carefully read all...

Страница 3: ...ONS PRODUCT FEATURES PRODUCT ADVANTAGES TECHNICAL SPECIFICATION AND INSTALLATION REQUIREMENTS PRODUCT INNER STRUCTURE INSTALLATION GUIDELINE INSTALLATION DIAGRAM OPERATING INSTRUCTIONS TROUBLE SHOOTIN...

Страница 4: ...ck up wrench on inlet and outlet fittings flat sides of fittings are located behind front cover The cold water inlet is on the right side it should be preceded by a high pressure discharge valve and a...

Страница 5: ...y water by disconnecting the water lines Leave the water lines disconnected until you intend to use the water heater This is not a do it yourself task Failure to have this appliance installed by a lic...

Страница 6: ...ay all plumbing paste or residue in them 10 The heating chamber is covered by composite nano insulation material it is natural if there might be a bit of smelI or green blue smoke when the unit is use...

Страница 7: ...he temperature drops to the set temperature 4 Malfunction of sensor when there is malfunction of the temperature sensor the heater stops working and displays E3 5 Conversion between degree Fahrenheit...

Страница 8: ...ng Pressure Water Connections Installation Temperature Setting Dimensions Weight PRODUCT CODE ECO110 GPM ECO110 220V 240V 11kW 50A 45 8A 6 AWG 0 53 GPM 2L min 5 PSI 85 PSI NPT Mounted Vertically Digit...

Страница 9: ...oper voltage rating Ground must be brought to the ground at the circuit breaker panel 4 This appliance MUST be permanently connected to the fixed circuit breaker If you do not use the heater please sw...

Страница 10: ...D INSTALLATION ON THE WALL Locate an appropriate place on a section of the wal I as mentioned above Fig 01 Front and back of the appliance Fig 02 Remove screws which are fixed at the front and back co...

Страница 11: ...ect the cable to the terminal blocks and please notice the guidance logo below the terminal blocks Fig 04 Connect PCB row line of the front cover to PCB of the back cover and then fix the front and ba...

Страница 12: ...the wall according to the following picture then drill three holes of 6 00mm diameter Put expansion bolts in the holes and then screw the self tapping screws into the expansion bolts Fig 06 Fix the a...

Страница 13: ...er seal rings at the connections When all water connections are completed check for leaks and take the necessary actions before proceeding Electrical connections 1 AIl electrical work must comply with...

Страница 14: ...e appliance stops working after 5 seconds the screen switches on the screen saver The display screen light will be off If somebody touches the screen the Iight will be on again 5 Press and to adjust t...

Страница 15: ...ber washer A Connect power to the unit B Change LCD C Connect LCD to the PCB Board A Open valve to get water B Open valve to get pressure C Change key or PCB A Set a lower temperature B Open valve big...

Страница 16: ...787 727 0277 PUERTO RICO Please feel free to contact us if you have any questions about our products warranty service or if you need assistance installing a unit We also strive for continuous improve...

Отзывы: