background image

VMM6 User’s Manual_________________________________________ 

17                                                                                                                         

VMM6 User’s Manual Rev.1.1 

 

 

Statements made by any person, including representatives of Carling, which are inconsistent or in conflict with the 
terms of this Limited Warranty, shall  not  be  binding  upon Carling unless reduced to  writing  and approved by an 
officer of Carling. 

IN NO CASE WILL CARLING BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES, DAMAGES FOR 
LOSS OF USE, LOSS OF ANTICIPATED PROFITS OR SAVINGS, OR ANY OTHER LOSS INCURRED BECAUSE 
OF INTERRUPTION OF 

SERVICE. IN NO EVENT SHALL CARLING’S AGGREGATE LIABILITY EXCEED THE 

PURCHASE PRICE OF THE PRODUCT(S) INVOLVED. CARLING SHALL NOT BE SUBJECT TO ANY OTHER 
OBLIGATIONS  OR  LIABILITIES,  WHETHER  ARISING  OUT  OF  BREACH  OF  CONTRACT  OR  WARRANTY, 
TORT (INCLUDING NEGLIGENCE), OR OTHER THEORIES OF LAW WITH RESPECT TO PRODUCTS SOLD 
OR  SERVICES  RENDERED  BY  CARLING,  OR  ANY  UNDERTAKINGS,  ACTS  OR  OMISSIONS  RELATING 
THERETO. 

Carling does not warrant that the functions contained in any software programs or products will meet p

urchaser’s 

requirements or that the operation of the software programs or products will be uninterrupted or error free. Purchaser 
assumes responsibility for the selection of the software programs or products to achieve the intended results, and 
for the installation, use and results obtained from said programs or products. No specifications, samples, descriptions, 
or  illustrations provided Carling to  Purchaser, whether directly, in  trade literature, brochures or other documentation 
shall be construed as warranties of any kind, and any failure to conform with such specifications, samples, descriptions, 
or illustrations shall not constitute any breach of 

Carling’s limited warranty. 

 

 Warranty Return Procedure: 

To apply for warranty claims, contact Carling Technologies or one of its Maretron dealers to describe the problem 
and determine the appropriate course of action. If a return is necessary, place the product in its original packaging 
together  with  proof  of  purchase  and  complete  a  Return  Merchandise  Authorization  (RMA)  on  the  following  web 
page: 

https://www.maretron.com/rma_request.php 

You will be contacted by email with instructions on where to send the unit for repair / evaluation. You are 
responsible for all shipping and insurance charges. Carling will return the replaced or repaired product with all 
shipping and handling prepaid except for requests requiring expedited shipping (i.e., overnight shipments). Failure 
to follow this warranty return procedure could result in the product’s warranty becoming null and void. 

 

Carling reserves the right to modify or replace, at its sole discretion, without prior notification, the warranty listed 
above. To obtain a copy of the then current warranty policy for Maretron

® 

products, please go to the following 

web page: 

http://www.maretron.com/company/warranty.php 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание A3801-1

Страница 1: ...______________________________ VMM6 Series Contura Digital SwitchModule 6 Rocker User s Manual Revision 1 1 Copyright 2020 Carling Technologies Inc 60 Johnson Ave Plainville CT 06062 USA All Rights Re...

Страница 2: ...1 Ordering Options 4 INSTALLATION 6 UNPACKING THE BOX 6 CHOOSING INSTALLATION LOCATION 6 MOUNTING THE VMM6 6 Figure 6 Mounting Panel Cutout Dimension 6 CONNECTING THE VMM6 7 CONNECTOR PIN DESCRIPTION...

Страница 3: ...res Figure 1 Hardware Description Front View 2 Figure 2 Hardware Description Top View 3 Figure 3 Hardware Description Side View 3 Figure 4 Hardware Description Back View 3 Figure 5 Optional VMM to NME...

Страница 4: ...he VMM6 by using a Maretron USB100 or IPG100 tethering the NMEA2000 network to a PC running N2KAnalyzer Control MPower and other Maretron systems with the VMM6 through an NMEA 2000 Network Using stand...

Страница 5: ...be numbered as follows There is a total of twelve blue LEDs each con gurable via CAN message to act as a backlight or a function indicator The LEDs are located under the top and bottom of each actuato...

Страница 6: ...User s Manual_________________________________________ 3 VMM6 User s Manual Rev 1 1 Figure 2 Hardware Description Top View Figure 3 Hardware Description Side View Figure 4 Hardware Description Back V...

Страница 7: ...n Table 1 Ordering Options PART NUMBER DESCRIPTION A3702 VMM to NMEA 2000 Adapter Cable 2m 3702 A3801 1 Contura II ALL Position Momentary ON w VMM to NMEA 2000 Adapter Cable 2m A3801 2 Contura II Righ...

Страница 8: ...VMM6 User s Manual_________________________________________ 5 VMM6 User s Manual Rev 1 1...

Страница 9: ...ng depth 6 recommended clearance needed for proper cable bend radius The VMM6 is temperature rated to 85 C 185 F Mount VMM6 away from engines or engine rooms where the operating temperature exceeds th...

Страница 10: ...ive pin male connector found on the VMM to NMEA 2000 Adapter Cable This connector is known as a DeviceNet micro connector You connect the VMM6 to a NMEA 2000 network using a Maretron NMEA 2000 cable o...

Страница 11: ...e default data instance whose state is reflected by the LED s on the VMM6 is Instance 32 The unit will pair with Maretron CLMD12 and CLMD16 to toggle each unit s first 6 ECB s ON and OFF If more than...

Страница 12: ...will indicate the indicator bank instance value that will be transmitted with the switch status in the 127501 Binary Status Report status message To change the value of this field change the value of...

Страница 13: ...the switch will transmit the state ON and these two values will remain the same until the top of the switch is pressed 3 Positions The rocker switch acts as two momentary switches When powered on the...

Страница 14: ...ed then the LED behind the top or bottom as appropriate of the switch will be lit at all times and the Data Instance and Indicator fields will be ignored Advanced Tab Figure 9 Advanced Tab Dialog Box...

Страница 15: ...the mounting surface Check the security of the cable connected to the NMEA 2000 connector and tighten if necessary Troubleshooting If you notice unexpected operation of the Maretron VMM6 follow the tr...

Страница 16: ...96 Product Information N A 126998 Configuration Information N A 065300 Proprietary N A Protocol PGNs 059392 ISO Acknowledge N A 059904 ISO Request N A 060928 ISO Address Claim N A 065240 ISO Address C...

Страница 17: ...y ON A3801 2 Right Switch is 3 Position A3801 3 All Positions Momentary ON A3801 4 Right Switch is 3 Position A3801 5 No Actuators ALL Positions Momentary ON A3801 6 No Actuators Right Switch 3 Positi...

Страница 18: ...eep 5 Hz to 500 Hz Amplitude 5g 20 Cycles in each plane Vibration Random EN 60068 2 64 1995 Method 1 Random excitation at 10 150 220 and 350 Hz breakpoint frequencies 5 hours in each axis Vibration Re...

Страница 19: ...requirements below shall be limited to the repair or replacement at Carling s option of any product not meeting the above limited warranty and which is returned to Carling or if Carling is unable to...

Страница 20: ...btained from said programs or products No specifications samples descriptions or illustrations provided Carling to Purchaser whether directly in trade literature brochures or other documentation shall...

Страница 21: ...rine Electronics Association www nmea org VMM6 NMEA 2000 Periodic Data Transmitted PGNs PGN 127501 Binary Status Report The VMM6 uses this PGN to transmit the state of the 12 switch throws Field 1 Ind...

Отзывы: