Mareli Systems PB 13 Скачать руководство пользователя страница 3

3

Mareli Systems

1. PURPOSE

The stove is purposed to heat domestic and public premises by the means of pellets. 

The stove is equipped with a steel water jacket designed for heating systems with water 

temperature up to 90º C at a maximum super pressure up to 0,15 Mpa. Tests are run at 

pressure of 0,3 Mpa. 

The stove is designed and manufactured to work with A-class pellets only

( DIN  plus  51731 ) with the following characteristics:

What are the pellets.

The pellets are produced by compressed wood-

en waste left from the production of various 

furniture, sawmills and others. This type of 

fuel is environmentally friendly because in 

the production process no agglutinate agents 

(glues, resins and others) are added. Actual-

ly, the integrity of the pellets is guaranteed by 

the lignite – a natural ingredient contained in 

the wood itself. While the wood has a calorie 

capacity of 4.4 kW/kg (15% humidity at 18 

months drying), the pellets have 5.2 kW/kg.

•  Material 100% pure conifer or broad-leaf 

wood;

•  Diameter Ф6/8 mm;

•  Length 20-30mm;

•  Calorie capacity 5.2 kW/kg;

•  Ash content < 8%;

The use of pellets with characteristics different from the recommended may result in 

power decrease, unstable and inconsistent work of the stove. 

Info: To ensure the proper work of the stove the pellets must be stored in a dry place!
Recharging of pellets can be done during work, with the following sequence:

1. Open the bunker (located at the top rear of the product);

2. Fill the hopper, using non-combustible container;

3. Close the lid of the bunker;
Attention!!!  Use gloves! Beware of hot surfaces!

Содержание PB 13

Страница 1: ...e Assembly and exploitation manual The present stove is designed and manufactured according to Standards BNS Bulgarian National Standard EN 14785 2006 Mareli Systems PB 13 18 24 30 Pellet stove Assemb...

Страница 2: ...aviouroromissions Anyinterventionorreplacementthatismadebyunauthorizedpeopleorusingnonoriginalspare partsfortheproductcanberiskyfortheuserandreleasethecompanyfromallliability Mostsurfacesofthestoveare...

Страница 3: ...ss no agglutinate agents glues resins and others are added Actual ly the integrity of the pellets is guaranteed by the lignite a natural ingredient contained in the wood itself While the wood has a ca...

Страница 4: ...trical consumption V Hz 60 310 60 310 60 310 60 310 Electrical supply V Hz 230 50 230 50 230 50 230 50 Water jacket capacity L 26 31 37 41 Working pressure bar 0 5 2 0 0 5 2 0 0 5 2 0 0 5 2 0 Space he...

Страница 5: ...e back of the wall Minimum distances from the wall to the stove should be at least 400 mm The mini mum space in front of the fireplace should be 1500 mm The minimal distance of the stove from combusti...

Страница 6: ...6 Mareli Systems CHECK ITEMS BEFORE INSTALLATION Chimney exit Chimney Connection to chimney Connection to the stove Security distances The floor Inlet air The chimney revision door...

Страница 7: ...ped with water serpentine and a solar panel For economy and efficiency of the system and a constant avail ability of cheap hot water a qualified assembly of the automatic shifter controlling the therm...

Страница 8: ...echanical wear and to the heat coming from the combustion products and condensation To be kept away from flammable materials The recommended chimney draft at work from 12 20 Pa Horizontal sections mus...

Страница 9: ...Systems 3 4Typesofconnectiontothechimney Chimney exit Moisture channel Chimney Thermal insulation External wall Connection to chimney Flue gas connection Heat generator T connection The chimney revis...

Страница 10: ...stion chamber must be carried out daily For this purpose make sure the fireplace has ceased operation and is completely cold Pull up the combustion pot and remove it from the stove and then clean it f...

Страница 11: ...11 Mareli Systems Cleaning the glass Use an non abrasive cloth Clean the flue gas outlet Cleaning the pellet bunker Combustion chamber Clean the ashtray PS...

Страница 12: ...12 Mareli Systems PB Cleaning the glass Use an non abrasive cloth Cleaning the pellet bunker Clean the flue gas outlet Combustion chamber Clean the ashtray...

Страница 13: ...13 Mareli Systems COLD WATER HOT WATER CHIMNEY OUTLET AIR INLET...

Страница 14: ...the fireplace may fall hot burning particles as hot ash and small particles burning coal which could lead to a fire in the heated room It is therefore necessary that the product always works with a t...

Страница 15: ...h exhaust temperature Er06 Pellet Thermostat open flame return from the brazier Er07 Encoder Error The error may occur due to lack signal from Encoder Er08 Encoder Error The error can occur due to pro...

Страница 16: ...fy the combustion power of the system It can be set in automatic or manual modality In the first case the system chooses the combustion power In the second case the user selects the desired power On t...

Страница 17: ...nday and then set the switching on and off times Monday ON OFF 09 30 11 15 V 00 00 00 00 00 00 00 00 Monday____________ Tuesday Wednesday Thrusday Friday Mon Fri Sat Sun USER MENU 2 Menu is accessed b...

Страница 18: ...auto or manual mode in the first case the system chooses the power combustion while in the second one the user selects the power On the left of the display the combustion mode is reported A automatic...

Страница 19: ...irmware code and firmware version Data are not modifiable The typologies of board that can appear are MSTR Master INP Input KEYB Keyboard OUT Output CMPS Composite SENS Sensor COM Communication Acoust...

Страница 20: ...VC 34 33 GND S6 IN6 36 35 GND S4 IN7 CN1 RS232 RS485 POWER CABLE COMBUSTION FAN IGNITER SAFETY AUGER PUMP SAFETY THERMOSTAT WATER PROTECTION RETURN FLAME PRESSURE SWITCH EXHAUST PROBE ROOM THERMOSTAT...

Страница 21: ...21 Mareli Systems FIRST CONFIGURATION First select the plumbing installation parameter P26 from the Enable menu of the Technical menu...

Страница 22: ...22 Mareli Systems...

Страница 23: ......

Страница 24: ...hey are due to printing or transcription errors We reserve the right to make any change that appears to be necessary or useful without harm the essential characteristics Mareli Systems MareliSystems I...

Отзывы: