This Manu allows selecting the programming modalities and and the Ignition/Extinguishing time slots.

 

Disable

 

 

Daily

 

Weekly

 

Week

-

End

 

 

Modality - It allows selecting the disired modality, or disable all set programming.

1. Enter modification mode through the key 

P3

.

2. Select the chosen modality (Daily, Weekly or Week end).

3. Enable/disable chrono modality through the keys 

P2

.

4. Save the settings through the keys 

P3

.

Programming

The system includes three type of programming: Daily, Weekly, Week end. 

After selecting the desired kind of programming:

1. Select the programming time through the keys 

P4/P6

.

2. Enterthe adjustment modality (selected time will be flashing) through the keys 

P3

.

3. Change the time via keys  

P4/P6

.

4. Save the programmong with the keys 

P3

.

5. Enable (a “V” is displayed) or disable the time slot (a “V” is not displayed”) by 

pressing the keys 

P5

.

Daily

Select the day of the week to program and set the ignition and extinguishing times.
Programs around midnight

Set the clock On of the previous day at the desired time: Ex. 20.30

Set the clock of OFF of the previous day at:  23:59

Set the clock On of the following day at  00:00

Set the clock of OFF of the following day at the desired time: Ex. 6:30

The system turns on at 20.30 on Tuesday and turns off at 6.30 on Wednesday

Weekly

The programs are the same for all days of the week.
Week-end

Choose between 'Monday-Friday' and 'Saturday-Sunday' and then set the switching 

on and off times.

 

 

Monday 

 

 

    ON             OFF 

  09:30           11:15  V 

  00:00           00:00 

  00:00           00:00 

Monday

____________ 

Tuesday 

Wednesday  

Thrusday 

Friday

 

Mon-Fri 

Sat-Sun 

 

USER MENU 2

Menu is accessed by pressing the 

P3 

buttons for 3 seconds .

Settings 
Time and Date - Used to set the day, month, year and current time.
Language - Menu to modify the language of the LCD board.

Display Menu
Contrast
 - Menu used to regulate the display contrast.
Brightness - It allows you to adjust the screen brightness. 
Minimum Brightness - Menu used to regulate the lighting of the display when the command aren’t used.
Keyboard Address - This Menu is protected by a password (the password is 1810), that allows you to set the RS485

node address. With the bus 485 it is not possible to have more nodes with the same address.
Sound - It allows you to enable or disable sound from the control panel.
Node List - This menu shows: communication address of the board, typology of the board, firmware code and 

firmware version. Data are not modifiable. The typologies of board that can appear are:

MSTR - Master; 

INP - Input ;  

KEYB - Keyboard; 

 

OUT - Output;

CMPS - Composite;  SENS - Sensor; 

COM - Communication;

Acoustic Alarm - It allows to enable or disable the acoustic alarm of the keyboard.

Auger Calibration - It allows to modify the value set in firm of Auger’s speed or On times. The values are in the 

range – 7 ÷ 7. The firm’s value is 0.

Fan Calibration - It allows to modify the value set in firm of Combustion Fan’s speed. The values are in the range 

– 7 ÷ 7. The firm’s value is 0.
Summer-Winter - This Menu allows you to modify the hydraulic plant functioning depending on the season.

USER MENU 2

Settings

Time and Date - It allows you to set day, month, year and current time.

Language - It allows you to modify the language of the keyboard.

Recipe - Menu for the selection of the combustion recipe.

Summer/Winter - Menu to edit the functioning of the hydraulic system according to the season.

Service

Counters - 

Ignitions

 (Number of attempted Ignitions) - 

Failed Ignition

 (Number of failed ignitions) - 

Working hours

 (Operating hours in Run mode, Modulation and Safety).

Errors List - The menu shows the last 10 errors; in each line the error code and time/date of the error itself 

are shown.

Secondary Information - Information about configurable outputs and inputs are only available if they have 

been set.

Cleaning Reset - Menu to reset the function ‘System Maintenance 2’. It is displayed only if T67>0.

Auger Calibration - This menu allows you to modify the default values of the Auger speed or its On times. 

You can set the values in a range within –7÷7. The default value is 0. 

Fan Calibration - This menu allows you to modify the default values of the Combustion Fan speed. You can 

set the values in a range within –7÷7. The default value is 0.

Mixer Valve - Menu to manage the Mixer Valve operation.

Automatic Power - This menu allows you to set combustion power in automatic mode only. If you set it, 

power change menus are no longer displayed.

Loading - The procedure enables the pellet manual charge and it is automatically interrupted after 300 

seconds. In order to enable this function, the system must be on mode Off.

Loading Test - The procedure allows calculating the amount of pellet used in 10 minutes with the auger.

Display

Contrast - It allows you to adjust the screen contrast.

Screen saver - This Menu allows the user to enable and disable the screen saver.

Acoustic Alarm - Menu to enable/disable the acoustic alarm.

Minimum Brightness - It allows you to adjust the screen brightness when not using the controls.

Содержание PB 13

Страница 1: ...e Assembly and exploitation manual The present stove is designed and manufactured according to Standards BNS Bulgarian National Standard EN 14785 2006 Mareli Systems PB 13 18 24 30 Pellet stove Assemb...

Страница 2: ...aviouroromissions Anyinterventionorreplacementthatismadebyunauthorizedpeopleorusingnonoriginalspare partsfortheproductcanberiskyfortheuserandreleasethecompanyfromallliability Mostsurfacesofthestoveare...

Страница 3: ...ss no agglutinate agents glues resins and others are added Actual ly the integrity of the pellets is guaranteed by the lignite a natural ingredient contained in the wood itself While the wood has a ca...

Страница 4: ...trical consumption V Hz 60 310 60 310 60 310 60 310 Electrical supply V Hz 230 50 230 50 230 50 230 50 Water jacket capacity L 26 31 37 41 Working pressure bar 0 5 2 0 0 5 2 0 0 5 2 0 0 5 2 0 Space he...

Страница 5: ...e back of the wall Minimum distances from the wall to the stove should be at least 400 mm The mini mum space in front of the fireplace should be 1500 mm The minimal distance of the stove from combusti...

Страница 6: ...6 Mareli Systems CHECK ITEMS BEFORE INSTALLATION Chimney exit Chimney Connection to chimney Connection to the stove Security distances The floor Inlet air The chimney revision door...

Страница 7: ...ped with water serpentine and a solar panel For economy and efficiency of the system and a constant avail ability of cheap hot water a qualified assembly of the automatic shifter controlling the therm...

Страница 8: ...echanical wear and to the heat coming from the combustion products and condensation To be kept away from flammable materials The recommended chimney draft at work from 12 20 Pa Horizontal sections mus...

Страница 9: ...Systems 3 4Typesofconnectiontothechimney Chimney exit Moisture channel Chimney Thermal insulation External wall Connection to chimney Flue gas connection Heat generator T connection The chimney revis...

Страница 10: ...stion chamber must be carried out daily For this purpose make sure the fireplace has ceased operation and is completely cold Pull up the combustion pot and remove it from the stove and then clean it f...

Страница 11: ...11 Mareli Systems Cleaning the glass Use an non abrasive cloth Clean the flue gas outlet Cleaning the pellet bunker Combustion chamber Clean the ashtray PS...

Страница 12: ...12 Mareli Systems PB Cleaning the glass Use an non abrasive cloth Cleaning the pellet bunker Clean the flue gas outlet Combustion chamber Clean the ashtray...

Страница 13: ...13 Mareli Systems COLD WATER HOT WATER CHIMNEY OUTLET AIR INLET...

Страница 14: ...the fireplace may fall hot burning particles as hot ash and small particles burning coal which could lead to a fire in the heated room It is therefore necessary that the product always works with a t...

Страница 15: ...h exhaust temperature Er06 Pellet Thermostat open flame return from the brazier Er07 Encoder Error The error may occur due to lack signal from Encoder Er08 Encoder Error The error can occur due to pro...

Страница 16: ...fy the combustion power of the system It can be set in automatic or manual modality In the first case the system chooses the combustion power In the second case the user selects the desired power On t...

Страница 17: ...nday and then set the switching on and off times Monday ON OFF 09 30 11 15 V 00 00 00 00 00 00 00 00 Monday____________ Tuesday Wednesday Thrusday Friday Mon Fri Sat Sun USER MENU 2 Menu is accessed b...

Страница 18: ...auto or manual mode in the first case the system chooses the power combustion while in the second one the user selects the power On the left of the display the combustion mode is reported A automatic...

Страница 19: ...irmware code and firmware version Data are not modifiable The typologies of board that can appear are MSTR Master INP Input KEYB Keyboard OUT Output CMPS Composite SENS Sensor COM Communication Acoust...

Страница 20: ...VC 34 33 GND S6 IN6 36 35 GND S4 IN7 CN1 RS232 RS485 POWER CABLE COMBUSTION FAN IGNITER SAFETY AUGER PUMP SAFETY THERMOSTAT WATER PROTECTION RETURN FLAME PRESSURE SWITCH EXHAUST PROBE ROOM THERMOSTAT...

Страница 21: ...21 Mareli Systems FIRST CONFIGURATION First select the plumbing installation parameter P26 from the Enable menu of the Technical menu...

Страница 22: ...22 Mareli Systems...

Страница 23: ......

Страница 24: ...hey are due to printing or transcription errors We reserve the right to make any change that appears to be necessary or useful without harm the essential characteristics Mareli Systems MareliSystems I...

Отзывы: