Marecoluce Challenge Solar Скачать руководство пользователя страница 13

13

CHALLENGE SOLAR

Faults and remedies Challenge Solar

Fault

Cause

Remedy

Info LED 

flashing red

Charging interrupted due to 

excessive charging current

- Charging automatically continues as soon as the charging 

current lies back to the permissible range

Luminaires cannot 

be operating or just 

for a while

+

info LED flashing red

Luminaires output is switched off 

due to battery overvoltage

- Check the luminaires

Luminaires output is switched off 

due to an output short circuit 

- Disconnect the lumiaires

- Correct the casue of the short circuit

- Reconnect the luminaires

Luminaires output is switched off 

due to overheating of the 

electronic circuit board

The luminaires output automatically switches on again once the 

electronic circuit board has cooled down

- Improve the cooling air circulation

remove any other heat sources

- Check the conditions of use and the mounting location

Luminaires cannot 

be operating

+

info LED flashing red

+

battery LED flashing 

red

Luminaires output is switched off 

due to too low battery voltage

The luminaires output automatically switches on again once the 

battery voltage lies back within the permissible range

- Pre-charge the battery

- Equip the luminaires directly connected to the battery with deep 

discharge protection

- Check the battery and replace it if necessary

Luminaires cannot 

be operating

+

info LED flashing red

+

green

Luminaires output is switched off 

due to excessive battery voltage

The luminaires output automatically switches on again once the 

battery voltage lies back within the permissible range

External charging source is not 

voltage-limited

- Check the external charging source

Luminaires cannot 

be operating

+

info LED illuminates 

green

Defective luminaires or installation 

mistake

- Connect the luminaires correctly

- Replace the luminaires

Battery is 

not charged

Solar panel not connected

- Connect the solar panel

Solar panel connected with incor-

rect polarity

- Connect the solar panel with the correct polarity

Short circuit at solar panel input

- Correct the cause of the short circuit

Incorrect solar panel voltage

- Use a solar panel with the specified voltage

Solar panel defective

- Replace the solar panel

Battery display 

 jumps quickly

Large pulse current

Adjust the current consumption to match the battery capacity

Battery is defective

Replace the battery

No Display

Battery voltage too low

- Pre-charge the battery

The external fuse in the battery 

connection cable has blown.

- Replace the external fuse

Battery is not connected

- Unclamp all connections

- Connect a (new) battery with the correct polarity

- Reconnect the solar panel and the luminaires

Battery is connected with the 

wrong polarity

Battery is defective

User's manual

nd

2     LED flashing 

Содержание Challenge Solar

Страница 1: ...lation of the fitting Pag 3 Challenge Solar installation of the fitting Pag 4 Electronic circuit board Deva Solar and Stud Solar Pag 6 Programming Deva Solar Pag 7 Programming Stud Solar Pag 8 Program...

Страница 2: ...icollars of the panel Position the panel 3 on the brackets 4 of the pole top and tighten the screws 2 of the semicollars Open the door of the battery box by using the key included Place the battery 6...

Страница 3: ...lectrical compartment The sensor must be in clean contact with a supply voltage between 12VDC and 17VDC Untighten the screw 1 Loosen the screw 2 Remove the gear tray cover 3 Insert Stud Solar 1 or Stu...

Страница 4: ...X 0 8 Nm 1b 5 7 2 5 Nm 3SX SX DX 2 8 9 8 1 24 24LL 36 2 5 Nm CHALLENGE SOLAR CHALLENGE SOLAR Electronic circuit board pre installed and factory set for programming modes see pag 8 9 10 Installation of...

Страница 5: ...G the luminaires 1x60W 2x30W 1x90W have n 2 supply cables connect these two supply cables together first then connect them to the terminal block Position the pole top without the solar panels on the t...

Страница 6: ...f the increased luminosity 1 2 or 3 minutes SMART In this mode the luminosity of the LEDs is variable Priority is given to battery charge this calculated each night based on the energy transferred fro...

Страница 7: ...the increased luminosity 1 2 or 3 minutes SMART In this mode the luminosity of the LEDs is variable Priority is given to battery charge this calculated each night based on the energy transferred from...

Страница 8: ...ation OFF OFF 8 hours OFF ON 10 hours ON OFF 4 hours at sunset and 2 hours before sunrise ON ON from sunset to sunrise Dip 5 LEDs at 100 luminosity if the system connects to the grid OFF Connected ON...

Страница 9: ...0 and the time for the movement sensor is set to 2 minutes Dip 1 Battery duration SMART mode OFF 3 nights duration without recharging ON 2 nights duration without recharging Dip 2 Programming mode OFF...

Страница 10: ...y has insufficient charge to switch to light up the product the ECB remains in this operating mode up until the end of the pre set light up time which can be set up via dip switch 4 flashes LEDs off a...

Страница 11: ...EDs for displaying the state of charge red yellow green1 and green 2 3 Terminal block for connecting the solar panel 4 Terminal block for connecting the battery 5 Terminal block for connection the lum...

Страница 12: ...ammed for an 8 hours operation to change the setting follow the instructions of PA RC100 controller The 5 minutes On Off delay has been set to avoid that the luminaires switch on off if the panels are...

Страница 13: ...on Check the battery and replace it if necessary Luminaires cannot be operating info LED flashing red green Luminaires output is switched off due to excessive battery voltage The luminaires output aut...

Страница 14: ...g should be carried out while panel is cool either in early morning or in late evening Cleaning consists in washing the panels with water and gentle detergents non abrasive by taking care to avoid str...

Страница 15: ...lation The product must be installed according to the supplied installation instructions For all the solar luminaires is required a periodical maintenance including the following steps To clean the so...

Страница 16: ...47032 Bertinoro FC Italia Via S Croce 121 z i tel 39 0543 4687 fax 39 0543 449051 info marecoluce it marecoluce it...