4.5.4 Repositioning the covering
Because of flaws on the tipper body (blows, recesses etc.) or its incorrect loading, the covering may move sideways when
used. In this case, act as follows to reposition it correctly:
WARNING!
During installation of the metal cable, it is strictly mandatory to wear gloves in order to prevent hand
injuring caused by the possible fraying of the metal mesh.
Spray all the pulleys of the covering with Svitol to ease the following operations:
1. Fold up the covering into the front part of the tipper body;
2. Loosen both rear tensioner plates;
3. Push manually the last bow towards the front part, on both sides, until there is the same distance between the last bow
and the right and left gear housings.
4. If the covering is manually operated, make sure that the operating rod is fastened in its housing.
5. Re-tighten the cables.