Maintenance: 

Marco machines have been designed to give many  years of trouble free service. The only regular 
maintenance required is occasional de -scaling. 

  Isolate machine from power supply. 

  Isolate machine from water supply. 

 

ALLOW TO COOL COMPLETELY! 

  Remove  the  front  panel  and  drain  water  from  machine  using  the  detachable  silicon  hose 

running down the front side of the machine. 

  Remove lid. 

  Remove  as  much  scale  as  possible  by  hand,  paying  particular  attention  to  level  probes 

(White plastic with steel tab).  Be very careful not to damage any attachments.  

  Use ScaleKleen, Marco part No. 8000270 or similar.  Follow instructions carefully. 

  Thoroughly clean and flush the machine before re -use. 

  Follow installation and first time operation instructions  

 

Cleaning: 

The exterior of these machines may be cleaned  with a damp cloth and a  light detergent.  Do  not 
use abrasive cloths or creams, as  this will spoil  the finish of  the machine.  Do not  use a  water  jet 
or  spray.    Beware  of  accidentally  operating  the  draw  off  tap  when  cleaning  the  front  of  the 
machine. 
 

Limescale: 

In  common  with  all  water  boiler  manufacturers,  service  calls  resulting  from  limescale  are  not 
covered  by  warranty.    Fitting  a  scale  reducer  is  recommended,  especially  in  hard  water  areas.  
This  can  reduce  the  build-up  of  scale  but  may  not  stop  it  altogether.    The  frequency  that 
descaling  is  required  depends  on  the  local  water  supply;  hard  water  areas  need  more  attention.  
A  scale  reducer  can  reduce  the  build  up  of  scaling,  but  may  not  stop  it  altogether.    Descaling  of 
the machine should ideally be carried out by qualified service personnel.  

 

Cautions and safety tips: 

  This appliance must be earthed.   

  Risk  of  flooding.    The  hose  supplied  with  this  unit  is  non-toxic  food  quality  tested  to  190psi.  

However, a hose is not a permanent connection.   It is, therefore, advisable to switch off boiler 
and close the stopcock valve when boiler is not in use, e.g. overnight, weekends etc.  

  Risk of scalding.  Beware of accidentally pressing the font buttons while cleaning the fonts.  

  The utmost care  has been taken in the manufacture and testing of this unit.  Failure to install, 

mai

ntain and / or operate this boiler according to the manufacturer’s instructions may result in 

conditions  that  can  cause  injury  or  damage  to  property.    If  in  any  doubt  about  the 
serviceability of the boiler always contact the manufacturer or your own suppli er for advice. 

 

Содержание OCEANIC 8.4kW

Страница 1: ...Limited 63d Heather Road Sandyford Industrial Estate Dublin 18 Marco Beverage Systems Limited Shire House Strixton Manor Strixton Wellingborough Northants NN29 7PA Ireland Tel 353 0 1 295 2674 Ireland Fax 353 0 1 295 3715 email sales marco ie www marco ie UK Tel 44 0 2072 744 577 UK Fax 44 0 2079 788 141 email sales marco bev co uk www marco bev co uk ...

Страница 2: ...eral gallons through Connect right angled tailpiece of the hose to the inlet valve of the boiler again 3 4 BSP Make sure the sealing washer is fitted here also Turn on water and check for leaks Connect to a suitable power supply Font Installation Counter Drilling Holes need to be drilled in the counter for the mounting bolts 6 10mm diameter 4 holes are in the base plate Please use the dimensions s...

Страница 3: ...pense time for less quick font button click will set the font back into push hold mode After the volumes are set properly press the tactile button on the timer board once again Both pumps will turn on and off for 0 1s twice that will be heard as a double click meaning that the timer is out of calibration 3 Please note that there is no given order which font is to be calibrated first in fact they m...

Страница 4: ...water boiler manufacturers service calls resulting from limescale are not covered by warranty Fitting a scale reducer is recommended especially in hard water areas This can reduce the build up of scale but may not stop it altogether The frequency that descaling is required depends on the local water supply hard water areas need more attention A scale reducer can reduce the build up of scaling but ...

Отзывы: