USER SET UP OPTIONS: 

 
 
 

User Setup 

 

Screen view 

Description 

Default 

value 

 

Sets new tank temperature. 
Range: 60 – 99.5 °C 
Resolution: 0.5 °C 

95.0 

 

Sets dispense time. 
Range: 0 – 99.9 seconds 
Resolution: 0.1 second 
For PUSH & HOLD mode set to 0 (default). 

00.0 

 

Sets number of pauses during time dispense. 
Range: 0 – 20 
If machine set as PUSH & HOLD then number of 
pauses has no impact on dispense. 

00 

 

Sets pause time (same for each of the pauses). 
Range: 0 – 20.0 seconds 
Resolution: 0.1 second 
If machine set as PUSH & HOLD then time of 
pause has no impact on dispense. 

00.0 

 

Press the 

eco

 button to save all the values and 

reset the machine. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание ECOSMART PB10

Страница 1: ...in max Marco Beverage Systems Limited 63d Heather Road Sandyford Industrial Estate Dublin 18 Marco Beverage Systems Limited Shire House Strixton Manor Strixton Wellingborough Northants NN29 7PA Irelan...

Страница 2: ...ical installation Electrical specification 2 8kW 230V 50Hz A moulded 13A plug is factory fitted A suitable 13A outlet is all that is required Plumbing installation procedure Mains water pressure requi...

Страница 3: ...User Interface NOTE Because the boiler is electronically controlled no priming is necessary The element cannot switch on until a safe level of water is reached EcoSmart Features The EcoSmart Ecoboile...

Страница 4: ...k temperature 0 5 C accuracy Bottom part shows current machine status Entering Setup Mode To enter setup mode press power and eco buttons on the front panel at the same time The display will show USER...

Страница 5: ...USH HOLD mode set to 0 default 00 0 Sets number of pauses during time dispense Range 0 20 If machine set as PUSH HOLD then number of pauses has no impact on dispense 00 Sets pause time same for each o...

Страница 6: ...k size and element power This is a factory setting and should only be changed by trained personnel Range 0 20 0 seconds Resolution 0 1 second 3 0 Sets the time at which machine waits for the water too...

Страница 7: ...ode DISPENSE WATER TO COOL THE TANK Machine can not take more cold water to cool the tank because it is full Water needs to be dispensed to allow room for more cold water to come in and finish cooling...

Страница 8: ...nit MANUAL FILL if the boiler is not plumbed into a water supply the operator must select Manual Fill mode for best operation of the boiler In this mode the water is added manually by the operator ECO...

Страница 9: ...uch scale as possible by hand paying particular attention to level probes White plastic with steel tab Be very careful not to damage any attachments Use ScaleKleen Marco part No 8000270 or similar Fol...

Страница 10: ...ocations indicated on the picture and rotate to seperate the panels Note There is no need to lever the screwdriver a small rotation is all that is required b a d c 6 To remove the lower front panel ro...

Страница 11: ...Intentionally Blank...

Страница 12: ...Intentionally Blank...

Отзывы: