Marco Ecoboiler WMPB3 Скачать руководство пользователя страница 18

Service Manual  Ecoboiler  wallmount 1000671 100676 061010 

 

 

Page 18 of 18 

 

4.13.

 

Spare Parts List  

 
 

Part 
Number 

Description 

Model Variant 
T3 

T5 

PB3 

PB5 

1400550 

Circlip for Tap 

X  

X   

 

 

1401170 

Nut Chromed for Tap 

X  

 

 

1500950 

ELEMENT 2.4kW 230V 

1501217 

Push Button Metal 230V 

 

 

1502156 

Valve Dispense Solenoid Muller 

 

 

1502190 

Valve Inlet Solenoid 

1600345 

PCB Ecoboiler Control Rev 2.0 

1600349 

PCB Ecoboiler Display 10L Rev 1.0 

 

 

1600691 

Thermistor Assembly 

2100279 

Tap Hot Water 

X  

X  

 

 

2301463 

Level Probe Assembly 

8000240 

Urn Cleanser (800g Tub) 

8800121 

Descale Box 

– 6 Packs 

1500470 

O RING CLEANOUT DOOR 

1501217 

Push Button Metal 230V 

 

 

 
 
 

Part 
Number 

Description 

Model Variant 
T3 

T5 

PB3 

PB5 

ECOW-026F 

Exterior Lid 

ECOW-015F 

Base cover plate  

ECOW-006F 

WM Clean out door  

ECOW-020F 

Left Wing  

ECOW-021F 

Right Wing   

ECOW-012F 

Center Panel 

ECOW-019F 

THERMAL SWITCH BRACKET 

 
 
 
 
 
 
 
 
 
 
 

MARCO is an 

ISO9001:2000 

Registered Company. 

 

 

 
 
 
 

Содержание Ecoboiler WMPB3

Страница 1: ...boiler WMT3 Ecoboiler WMPB3 SERVICE MANUAL Marco Beverage Systems Ltd 63d Heather Road Sandyford Industrial Estate Dublin 18 Republic of Ireland Ireland Tel 01 295 2674 Ireland Fax 01 295 3715 UK Tel...

Страница 2: ...ning 6 3 7 Limescale 6 3 8 Cautions and Safety Tips 6 4 TECHNICAL DATA 4 1 General Description 6 4 2 External Arrangement 7 4 3 Internal Arrangement 7 4 4 Access to internal components 8 4 5 PCBs 9 4...

Страница 3: ...orised by Marco should carry out installation and maintenance of these machines Marco accepts no responsibility for any damage or injury caused by incorrect or unreasonable installation and operation...

Страница 4: ...derside o When the machine is plumbed from the rear connect right angled tailpiece to the inlet valve of the boiler again BSP o When the machine is plumbed from the underside connect non angled tailpi...

Страница 5: ...calibration process the steps below should be followed 5 If the tactile switch is pressed too early and the temperature is set lower than desired the tester should simply repeat calibration 6 If the t...

Страница 6: ...earthed Risk of flooding The hose supplied with this unit is non toxic food quality tested to 190psi However a hose is not a permanent connection It is therefore advisable to switch off boiler and cl...

Страница 7: ...ed centre panel Top tank access Lid High Level Probe Assembly 2300463 Low Level Probe Assembly 2300463 PCB Ecoboiler Control 1600345 ELEMENT 2 4kW 230V 1500950 Valve inlet Solenoid 1502190 Overflow Tu...

Страница 8: ...ol sufficiently 3 The removable Side Panels are fixed at the top of the machine 4 Unscrew with a Philips head screwdriver 5 Remove the panels in an upward and outward motion Reassembly To re attach th...

Страница 9: ...lace 4 5 PCBs 4 5 1 PCB Layout Internal PCB Layout PCB Ecoboiler Control 1600345 Controls the heater switching Controls the water inlet switching Controls tank temperature temperature adjustment PCB E...

Страница 10: ...Tab 2 Inlet Solenoid Tab 3 Neutral Tabs 4 Transformer 5 Mains Live In Tab 6 Relays Heater Switch the element 7 Heater Tab 8 On Off 2 way Connector Short circuited on this Ecoboiler machines power swit...

Страница 11: ...via a flashing RED LED 4 Eco Mode On LED s 5 Eco Mode On Of Switch 6 5 way connector to PCB Ecoboiler LED connector 7 4 way connector to PCB Ecoboiler BUTTONS connector 4 6 TROUBLESHOOTING DIAGNOSTIC...

Страница 12: ...this error is detected This is a recoverable error When the correct range of resistance is measured normal operation resumes Probable causes 1 The thermistor probe is unplugged from the 4way connecto...

Страница 13: ...cooled by when the inlet solenoid valve is opened If the water pressure is within the specifications 5 50psi the inlet solenoid should not be on for more than a few seconds If this water temperature h...

Страница 14: ...trol inputs into the PCB and are critical to the operation of the machine The wiring to these should be checked regularly and the probes themselves should be cleaned whenever the machine is serviced O...

Страница 15: ...rain hose is located at the base of the machine which is accessible by removing right side panel Use ScaleKleen Marco part No 8000270 or similar Follow instructions carefully Remove lid located on the...

Страница 16: ...Service Manual Ecoboiler wallmount 1000671 100676 061010 Page 16 of 18 4 9 Wiring Diagrams...

Страница 17: ...Service Manual Ecoboiler wallmount 1000671 100676 061010 Page 17 of 18...

Страница 18: ...PCB Ecoboiler Display 10L Rev 1 0 X X 1600691 Thermistor Assembly X X X X 2100279 Tap Hot Water X X 2301463 Level Probe Assembly X X X X 8000240 Urn Cleanser 800g Tub X X X X 8800121 Descale Box 6 Pac...