T20-T30 Servuce Manual 11/07/2014
Page 9 of 18
This allows access to most of the internal components and the machine does not need to be
drained for most maintenance or service operations.
If further access is required, the plastic Front Fascia Middle panel should be removed by
unscrewing the four cross recessed pan headed screws.
On Tap versions, the Tap assembly will need to be removed before the plastic Front Fascia
Middle can be removed.
The Tank can be drained by removing the plug from the end of the drain hose, and draining
into an external drain or a large container.
Inlet Solenoid Access:
To access the inlet solenoid, the PCB and PCB bracket need to be removed.
Unscrew the two cross-recessed pan headed screws holding the bracket in place.