T20-T30 Servuce Manual 11/07/2014
Page 15 of 18
4.7.
Tank Compone nts
The tank internals are detailed below. Care should be taken when cleaning inside the tank.
The level probes provide much of the control inputs into the PCB and are critical to the operation of
the machine. The wiring to these should be checked regularly and the probes themselves should be
cleaned whenever the machine is serviced.
There are 3 level probes on the T20 and T30 Ecoboiler versions.
The Ecoboiler T20/T30 tank is shown below
– only the low level probe is visible in the picture.
4.8.
Descaling Proce dure
To descale the machine thoroughly:
Unplug the machine.
Disconnect from the water supply.
Drain as much water from the tank as possible.
Remove the lids and allow the machine to cool completely.
Drain all the water from the machine.
Attempt to remove as much scale as possible by hand.
Reconnect machine and start up once again.
Add a descale solution (follow instructions as given). Flush the machine thoroughly before use