background image

©

S.p.A.

NORMAL MAINTENANCE 

INDICATORS THAT  THE PUMP IS FUNCTIONING CORRECTLY  

TO OPEN THE PUMP  

ENVIRONMENTAL DISPOSAL  

WARRANTY  

PACKAGING ENVIRONMENTAL DISPOSAL

Ø
Ø
Ø

Check frequently and keep the inlet filter clean.

Check every month the chamber and keep clean from any foreign matter.

Check every month that electrical wiring is in good condition.

Ø

Replace the rubber impeller every season or every 500 hours (for UP1 series).

Ø
Ø
Ø

Temperature of body and motor frame is within 60°C and 70°C (140 °F - 158 °F);

Regular flow and constant noise levels;

Amp-draw within the limits indicated in the diagrams.

Ø

It is recommended that a specialized service technician be consulted for any 

repair work or the replacement of worn out internal components, exclusively with 

original spare parts; during the warranty period, only by authorized Marco S.p.A. 

personnel, failing which the warranty will expire.

It is the responsibility of the owner to dispose of this product by means of the specific refuse 

collection structures indicated by the government or the local governing authorities.

The user is invited to effect a proper waste separation, in order to facilitate the recycling 

of the materials of which the packing is composed.

1)

The Warranty period is 2 years from date of purchase on production of the 

appropriate sales invoice.

2)

Should the original sales invoice not be available, then the 2 year warranty 

period will be valid from production date.

3)

The Warranty becomes null and void in the case of incorrect utilization or 

disregard of the instructions contained herein.

4)

The Warranty only covers original production defects.

5)

The Warranty does not cover any related installation costs involved.

6)

Transport costs are refundable only in the case where warranty has been duly 

accepted by Marco Spa and they will be limited to the actual shipment costs 

between Marco Spa warehouse and the client's delivery address.

7)

No credit notes or replacement items will be issued prior to the receipt and 

proper testing of any Marco goods that are deemed faulty.

6

Содержание 164 002 12-US - UP3-P 12V

Страница 1: ...164 002 12 US UP3 P 12V 164 002 13 US UP3 P 24V 25 07 19 Rev 01 S p A INSTRUCTIONS FOR USE SELF PRIMING ELECTRIC PUMP FOR TRANSFERRING VARIOUS LIQUIDS...

Страница 2: ...A 4 0 gpm psi 29 3 1 lb UP3 P AWG 16 WEIGHT WIRE SIZE FUSE FLOW RATE PRESSURE Self priming electric pump for the transfer of liquids of varied nature The pumping elements are made up of PTFE gears whi...

Страница 3: ...e has been no damage to the pump during transportation or storage Both inlet and outlet ports should be carefully cleaned removing possible dust or residual packaging material Verify that the availabl...

Страница 4: ...ase frequent cleaning and maintenance of the filter is advisable The standardfilter withstandsa maximumpositive pressure of0 5 bar The electrical installation of the pump must include a protection fus...

Страница 5: ...pumphas run dryfor too long a period Long periods of inactivity In this case it is advisable to add liquid directly into the chamber beforestart up Air leak at the suction pipe due to the following re...

Страница 6: ...spose of this product by means of the specific refuse collection structuresindicated bythe government orthe local governing authorities The user is invited to effect a proper waste separation in order...

Страница 7: ...G X 9 1 BRUSH HOLDER 10 1 BALL BEARING 11 1 COMPENSATION SPRING 12 2 O RING 13 2 WASHER 14 2 NUT 15 1 KEY X 16 1 IDLE GEAR 17 1 DRIVING GEAR 18 1 O RING 19 1 TOP PLATE 20 4 SCREW 21 2 NIPPLE 22 2 O RI...

Страница 8: ...S p A DIMENSIONS 10 3 8 50 2 60 2 3 8 41 1 5 8 101 4 151 6 80 3 1 8 64 2 1 2 102 4 38 1 1 2 60 2 3 8 41 1 5 8 118 4 5 8 159 6 1 4 5 1 4 1 7 5 8 NPT 3 8 8...

Страница 9: ...S p A DIAGRAMS FLOW RATE DIAGRAM AMPERE DRAW DIAGRAM 9 0 1 2 3 4 5 0 14 5 29 43 5 psi gpm 0 5 10 15 0 14 5 29 43 5 psi A A 12V A 24V...

Страница 10: ...ssion This declaration is valid for all products which are produced in accordance with the technical documentation which is a part of this declaration For verification of conformity with regard to the...

Страница 11: ......

Страница 12: ...f MARCO S p A reproduction prohibited All rights reserved For further information visit our web site www marco it Marco S p A Via Mameli 10 25014 Castenedolo Brescia Italy tel 39 030 2134 1 Fax 39 030...

Отзывы: